Cargando…
Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency
It is well-established that cyclic, but not static, mechanical loading has anabolic effects on bone. However, the function describing the relationship between the loading frequency and the amount of bone adaptation remains unclear. Using a combined experimental and computational approach, this study...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7591723/ https://www.ncbi.nlm.nih.gov/pubmed/33154964 http://dx.doi.org/10.3389/fbioe.2020.566346 |
_version_ | 1783601043444072448 |
---|---|
author | Scheuren, Ariane C. Vallaster, Paul Kuhn, Gisela A. Paul, Graeme R. Malhotra, Angad Kameo, Yoshitaka Müller, Ralph |
author_facet | Scheuren, Ariane C. Vallaster, Paul Kuhn, Gisela A. Paul, Graeme R. Malhotra, Angad Kameo, Yoshitaka Müller, Ralph |
author_sort | Scheuren, Ariane C. |
collection | PubMed |
description | It is well-established that cyclic, but not static, mechanical loading has anabolic effects on bone. However, the function describing the relationship between the loading frequency and the amount of bone adaptation remains unclear. Using a combined experimental and computational approach, this study aimed to investigate whether trabecular bone mechano-regulation is controlled by mechanical signals in the local in vivo environment and dependent on loading frequency. Specifically, by combining in vivo micro-computed tomography (micro-CT) imaging with micro-finite element (micro-FE) analysis, we monitored the changes in microstructural as well as the mechanical in vivo environment [strain energy density (SED) and SED gradient] of mouse caudal vertebrae over 4 weeks of either cyclic loading at varying frequencies of 2, 5, or 10 Hz, respectively, or static loading. Higher values of SED and SED gradient on the local tissue level led to an increased probability of trabecular bone formation and a decreased probability of trabecular bone resorption. In all loading groups, the SED gradient was superior in the determination of local bone formation and resorption events as compared to SED. Cyclic loading induced positive net (re)modeling rates when compared to sham and static loading, mainly due to an increase in mineralizing surface and a decrease in eroded surface. Consequently, bone volume fraction increased over time in 2, 5, and 10 Hz (+15%, +21% and +24%, p ≤ 0.0001), while static loading led to a decrease in bone volume fraction (−9%, p ≤ 0.001). Furthermore, regression analysis revealed a logarithmic relationship between loading frequency and the net change in bone volume fraction over the 4 week observation period (R(2) = 0.74). In conclusion, these results suggest that trabecular bone adaptation is regulated by mechanical signals in the local in vivo environment and furthermore, that mechano-regulation is logarithmically dependent on loading frequency with frequencies below a certain threshold having catabolic effects, and those above anabolic effects. This study thereby provides valuable insights toward a better understanding of the mechanical signals influencing trabecular bone formation and resorption in the local in vivo environment. |
format | Online Article Text |
id | pubmed-7591723 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75917232020-11-04 Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency Scheuren, Ariane C. Vallaster, Paul Kuhn, Gisela A. Paul, Graeme R. Malhotra, Angad Kameo, Yoshitaka Müller, Ralph Front Bioeng Biotechnol Bioengineering and Biotechnology It is well-established that cyclic, but not static, mechanical loading has anabolic effects on bone. However, the function describing the relationship between the loading frequency and the amount of bone adaptation remains unclear. Using a combined experimental and computational approach, this study aimed to investigate whether trabecular bone mechano-regulation is controlled by mechanical signals in the local in vivo environment and dependent on loading frequency. Specifically, by combining in vivo micro-computed tomography (micro-CT) imaging with micro-finite element (micro-FE) analysis, we monitored the changes in microstructural as well as the mechanical in vivo environment [strain energy density (SED) and SED gradient] of mouse caudal vertebrae over 4 weeks of either cyclic loading at varying frequencies of 2, 5, or 10 Hz, respectively, or static loading. Higher values of SED and SED gradient on the local tissue level led to an increased probability of trabecular bone formation and a decreased probability of trabecular bone resorption. In all loading groups, the SED gradient was superior in the determination of local bone formation and resorption events as compared to SED. Cyclic loading induced positive net (re)modeling rates when compared to sham and static loading, mainly due to an increase in mineralizing surface and a decrease in eroded surface. Consequently, bone volume fraction increased over time in 2, 5, and 10 Hz (+15%, +21% and +24%, p ≤ 0.0001), while static loading led to a decrease in bone volume fraction (−9%, p ≤ 0.001). Furthermore, regression analysis revealed a logarithmic relationship between loading frequency and the net change in bone volume fraction over the 4 week observation period (R(2) = 0.74). In conclusion, these results suggest that trabecular bone adaptation is regulated by mechanical signals in the local in vivo environment and furthermore, that mechano-regulation is logarithmically dependent on loading frequency with frequencies below a certain threshold having catabolic effects, and those above anabolic effects. This study thereby provides valuable insights toward a better understanding of the mechanical signals influencing trabecular bone formation and resorption in the local in vivo environment. Frontiers Media S.A. 2020-10-14 /pmc/articles/PMC7591723/ /pubmed/33154964 http://dx.doi.org/10.3389/fbioe.2020.566346 Text en Copyright © 2020 Scheuren, Vallaster, Kuhn, Paul, Malhotra, Kameo and Müller. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Scheuren, Ariane C. Vallaster, Paul Kuhn, Gisela A. Paul, Graeme R. Malhotra, Angad Kameo, Yoshitaka Müller, Ralph Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency |
title | Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency |
title_full | Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency |
title_fullStr | Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency |
title_full_unstemmed | Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency |
title_short | Mechano-Regulation of Trabecular Bone Adaptation Is Controlled by the Local in vivo Environment and Logarithmically Dependent on Loading Frequency |
title_sort | mechano-regulation of trabecular bone adaptation is controlled by the local in vivo environment and logarithmically dependent on loading frequency |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7591723/ https://www.ncbi.nlm.nih.gov/pubmed/33154964 http://dx.doi.org/10.3389/fbioe.2020.566346 |
work_keys_str_mv | AT scheurenarianec mechanoregulationoftrabecularboneadaptationiscontrolledbythelocalinvivoenvironmentandlogarithmicallydependentonloadingfrequency AT vallasterpaul mechanoregulationoftrabecularboneadaptationiscontrolledbythelocalinvivoenvironmentandlogarithmicallydependentonloadingfrequency AT kuhngiselaa mechanoregulationoftrabecularboneadaptationiscontrolledbythelocalinvivoenvironmentandlogarithmicallydependentonloadingfrequency AT paulgraemer mechanoregulationoftrabecularboneadaptationiscontrolledbythelocalinvivoenvironmentandlogarithmicallydependentonloadingfrequency AT malhotraangad mechanoregulationoftrabecularboneadaptationiscontrolledbythelocalinvivoenvironmentandlogarithmicallydependentonloadingfrequency AT kameoyoshitaka mechanoregulationoftrabecularboneadaptationiscontrolledbythelocalinvivoenvironmentandlogarithmicallydependentonloadingfrequency AT mullerralph mechanoregulationoftrabecularboneadaptationiscontrolledbythelocalinvivoenvironmentandlogarithmicallydependentonloadingfrequency |