Cargando…

Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm

BACKGROUND: This study aimed to introduce a novel analysis paradigm, referred to as 4-dimensional (4D) manometry based on biophysical analysis; 4D manometry enables the visualization of luminal geometry of the esophagus and esophagogastric junction (EGJ) using high-resolution-impedance-manometry (HR...

Descripción completa

Detalles Bibliográficos
Autores principales: Kou, Wenjun, Carlson, Dustin A., Patankar, Neelesh A., Kahrilas, Peter J., Pandolfino, John E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592175/
https://www.ncbi.nlm.nih.gov/pubmed/33178334
http://dx.doi.org/10.1177/1756284820969050
_version_ 1783601138783748096
author Kou, Wenjun
Carlson, Dustin A.
Patankar, Neelesh A.
Kahrilas, Peter J.
Pandolfino, John E.
author_facet Kou, Wenjun
Carlson, Dustin A.
Patankar, Neelesh A.
Kahrilas, Peter J.
Pandolfino, John E.
author_sort Kou, Wenjun
collection PubMed
description BACKGROUND: This study aimed to introduce a novel analysis paradigm, referred to as 4-dimensional (4D) manometry based on biophysical analysis; 4D manometry enables the visualization of luminal geometry of the esophagus and esophagogastric junction (EGJ) using high-resolution-impedance-manometry (HRIM) data. METHODS: HRIM studies from two asymptomatic controls and one type-I achalasia patient were analyzed. Concomitant fluoroscopy images from one control subject were used to validate the calculated temporal-spatial luminal radius and time-history of intraluminal bolus volume and movement. EGJ analysis computed diameter threshold for emptying, emptying time, flow rate, and distensibility index (DI), which were compared with bolus flow time (BFT) analysis. RESULTS: For normal control, calculated volumes for 5 ml swallows were 4.1 ml–6.7 ml; for 30 ml swallows 21.3 ml–21.8 ml. With type-I achalasia, >4 ml of intraesophageal bolus residual was present both pre- and post-swallow. The four phases of bolus transit were clearly illustrated on the time-history of bolus movement, correlating well with the fluoroscopic images. In the control subjects, the EGJ diameter threshold for emptying was 8 mm for 5 ml swallows and 10 mm for 30 ml swallows; emptying time was 1.2–2.2 s for 5 ml swallows (BFT was 0.3–3 s) and 3.25–3.75 s for 30 ml swallows; DI was 2.4–3.4 mm(2)/mmHg for 5 ml swallows and 4.2–4.6 mm(2)/mmHg for 30 ml swallows. CONCLUSIONS: The 4D manometry system facilitates a comprehensive characterization of dynamic esophageal bolus transit with concurrent luminal morphology and pressure from conventional HRIM measurements. Calculations of flow rate and wall distensibility provide novel measures of EGJ functionality.
format Online
Article
Text
id pubmed-7592175
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-75921752020-11-10 Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm Kou, Wenjun Carlson, Dustin A. Patankar, Neelesh A. Kahrilas, Peter J. Pandolfino, John E. Therap Adv Gastroenterol Original Research BACKGROUND: This study aimed to introduce a novel analysis paradigm, referred to as 4-dimensional (4D) manometry based on biophysical analysis; 4D manometry enables the visualization of luminal geometry of the esophagus and esophagogastric junction (EGJ) using high-resolution-impedance-manometry (HRIM) data. METHODS: HRIM studies from two asymptomatic controls and one type-I achalasia patient were analyzed. Concomitant fluoroscopy images from one control subject were used to validate the calculated temporal-spatial luminal radius and time-history of intraluminal bolus volume and movement. EGJ analysis computed diameter threshold for emptying, emptying time, flow rate, and distensibility index (DI), which were compared with bolus flow time (BFT) analysis. RESULTS: For normal control, calculated volumes for 5 ml swallows were 4.1 ml–6.7 ml; for 30 ml swallows 21.3 ml–21.8 ml. With type-I achalasia, >4 ml of intraesophageal bolus residual was present both pre- and post-swallow. The four phases of bolus transit were clearly illustrated on the time-history of bolus movement, correlating well with the fluoroscopic images. In the control subjects, the EGJ diameter threshold for emptying was 8 mm for 5 ml swallows and 10 mm for 30 ml swallows; emptying time was 1.2–2.2 s for 5 ml swallows (BFT was 0.3–3 s) and 3.25–3.75 s for 30 ml swallows; DI was 2.4–3.4 mm(2)/mmHg for 5 ml swallows and 4.2–4.6 mm(2)/mmHg for 30 ml swallows. CONCLUSIONS: The 4D manometry system facilitates a comprehensive characterization of dynamic esophageal bolus transit with concurrent luminal morphology and pressure from conventional HRIM measurements. Calculations of flow rate and wall distensibility provide novel measures of EGJ functionality. SAGE Publications 2020-10-24 /pmc/articles/PMC7592175/ /pubmed/33178334 http://dx.doi.org/10.1177/1756284820969050 Text en © The Author(s), 2020 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Kou, Wenjun
Carlson, Dustin A.
Patankar, Neelesh A.
Kahrilas, Peter J.
Pandolfino, John E.
Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm
title Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm
title_full Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm
title_fullStr Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm
title_full_unstemmed Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm
title_short Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm
title_sort four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592175/
https://www.ncbi.nlm.nih.gov/pubmed/33178334
http://dx.doi.org/10.1177/1756284820969050
work_keys_str_mv AT kouwenjun fourdimensionalimpedancemanometryderivedfromesophagealhighresolutionimpedancemanometrystudiesanovelanalysisparadigm
AT carlsondustina fourdimensionalimpedancemanometryderivedfromesophagealhighresolutionimpedancemanometrystudiesanovelanalysisparadigm
AT patankarneelesha fourdimensionalimpedancemanometryderivedfromesophagealhighresolutionimpedancemanometrystudiesanovelanalysisparadigm
AT kahrilaspeterj fourdimensionalimpedancemanometryderivedfromesophagealhighresolutionimpedancemanometrystudiesanovelanalysisparadigm
AT pandolfinojohne fourdimensionalimpedancemanometryderivedfromesophagealhighresolutionimpedancemanometrystudiesanovelanalysisparadigm