Cargando…
Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration
PURPOSE: Deformable image registration (DIR) in low‐contrast tissues is often suboptimal because of low visibility of landmarks, low driving‐force to deform, and low penalty for misalignment. We aim to overcome the shortcomings for improved reconstruction of time‐resolved four‐dimensional magnetic r...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592986/ https://www.ncbi.nlm.nih.gov/pubmed/32961002 http://dx.doi.org/10.1002/acm2.12988 |
_version_ | 1783601282430271488 |
---|---|
author | Nie, Xingyu Huang, Kirk Deasy, Joseph Rimner, Andreas Li, Guang |
author_facet | Nie, Xingyu Huang, Kirk Deasy, Joseph Rimner, Andreas Li, Guang |
author_sort | Nie, Xingyu |
collection | PubMed |
description | PURPOSE: Deformable image registration (DIR) in low‐contrast tissues is often suboptimal because of low visibility of landmarks, low driving‐force to deform, and low penalty for misalignment. We aim to overcome the shortcomings for improved reconstruction of time‐resolved four‐dimensional magnetic resonance imaging (TR‐4DMRI). METHODS AND MATERIALS: Super‐resolution TR‐4DMRI reconstruction utilizes DIR to combine high‐resolution (highR:2x2x2mm(3)) breath‐hold (BH) and low‐resolution (lowR:5x5x5mm(3)) free‐breathing (FB) 3D cine (2Hz) images to achieve clinically acceptable spatiotemporal resolution. A 2‐step hybrid DIR approach was developed to segment low‐dynamic‐range (LDR) regions: low‐intensity lungs and high‐intensity “bodyshell” (=body‐lungs) for DIR refinement after conventional DIR. The intensity in LDR regions was renormalized to the full dynamic range (FDR) to enhance local tissue contrast. A T1‐mapped 4D XCAT digital phantom was created, and seven volunteers and five lung cancer patients were scanned with two BH and one 3D cine series per subject to compare the 1‐step conventional and 2‐step hybrid DIR using: (a) the ground truth in the phantom, (b) highR‐BH references, which were used to simulate 3D cine images by down‐sampling and Rayleigh‐noise‐adding, and (c) cross‐verification between two TR‐4DMRI images reconstructed from two BHs. To assess DIR improvement, 8‐17 blood vessel bifurcations were used in volunteers, and lung tumor position, size, and shape were used in phantom and patients, together with the voxel intensity correlation (VIC), structural similarity (SSIM), and cross‐consistency check (CCC). RESULTS: The 2‐step hybrid DIR improves contrast and DIR accuracy. In volunteers, it improves low‐contrast alignment from 6.5 ± 1.8 mm to 3.3 ± 1.0 mm. In phantom, it improves tumor center of mass alignment (COM = 1.3 ± 0.2 mm) and minimizes DIR directional difference. In patients, it produces almost‐identical tumor COM, size, and shape (dice> 0.85) as the reference. The VIC and SSIM are significantly increased and the number of CCC outliers are reduced by half. CONCLUSION: The 2‐step hybrid DIR improves low‐contrast‐tissue alignment and increases lung tumor fidelity. It is recommended to adopt the 2‐step hybrid DIR for TR‐4DMRI reconstruction. |
format | Online Article Text |
id | pubmed-7592986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75929862020-11-02 Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration Nie, Xingyu Huang, Kirk Deasy, Joseph Rimner, Andreas Li, Guang J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Deformable image registration (DIR) in low‐contrast tissues is often suboptimal because of low visibility of landmarks, low driving‐force to deform, and low penalty for misalignment. We aim to overcome the shortcomings for improved reconstruction of time‐resolved four‐dimensional magnetic resonance imaging (TR‐4DMRI). METHODS AND MATERIALS: Super‐resolution TR‐4DMRI reconstruction utilizes DIR to combine high‐resolution (highR:2x2x2mm(3)) breath‐hold (BH) and low‐resolution (lowR:5x5x5mm(3)) free‐breathing (FB) 3D cine (2Hz) images to achieve clinically acceptable spatiotemporal resolution. A 2‐step hybrid DIR approach was developed to segment low‐dynamic‐range (LDR) regions: low‐intensity lungs and high‐intensity “bodyshell” (=body‐lungs) for DIR refinement after conventional DIR. The intensity in LDR regions was renormalized to the full dynamic range (FDR) to enhance local tissue contrast. A T1‐mapped 4D XCAT digital phantom was created, and seven volunteers and five lung cancer patients were scanned with two BH and one 3D cine series per subject to compare the 1‐step conventional and 2‐step hybrid DIR using: (a) the ground truth in the phantom, (b) highR‐BH references, which were used to simulate 3D cine images by down‐sampling and Rayleigh‐noise‐adding, and (c) cross‐verification between two TR‐4DMRI images reconstructed from two BHs. To assess DIR improvement, 8‐17 blood vessel bifurcations were used in volunteers, and lung tumor position, size, and shape were used in phantom and patients, together with the voxel intensity correlation (VIC), structural similarity (SSIM), and cross‐consistency check (CCC). RESULTS: The 2‐step hybrid DIR improves contrast and DIR accuracy. In volunteers, it improves low‐contrast alignment from 6.5 ± 1.8 mm to 3.3 ± 1.0 mm. In phantom, it improves tumor center of mass alignment (COM = 1.3 ± 0.2 mm) and minimizes DIR directional difference. In patients, it produces almost‐identical tumor COM, size, and shape (dice> 0.85) as the reference. The VIC and SSIM are significantly increased and the number of CCC outliers are reduced by half. CONCLUSION: The 2‐step hybrid DIR improves low‐contrast‐tissue alignment and increases lung tumor fidelity. It is recommended to adopt the 2‐step hybrid DIR for TR‐4DMRI reconstruction. John Wiley and Sons Inc. 2020-09-22 /pmc/articles/PMC7592986/ /pubmed/32961002 http://dx.doi.org/10.1002/acm2.12988 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Nie, Xingyu Huang, Kirk Deasy, Joseph Rimner, Andreas Li, Guang Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration |
title | Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration |
title_full | Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration |
title_fullStr | Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration |
title_full_unstemmed | Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration |
title_short | Enhanced super‐resolution reconstruction of T1w time‐resolved 4DMRI in low‐contrast tissue using 2‐step hybrid deformable image registration |
title_sort | enhanced super‐resolution reconstruction of t1w time‐resolved 4dmri in low‐contrast tissue using 2‐step hybrid deformable image registration |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592986/ https://www.ncbi.nlm.nih.gov/pubmed/32961002 http://dx.doi.org/10.1002/acm2.12988 |
work_keys_str_mv | AT niexingyu enhancedsuperresolutionreconstructionoft1wtimeresolved4dmriinlowcontrasttissueusing2stephybriddeformableimageregistration AT huangkirk enhancedsuperresolutionreconstructionoft1wtimeresolved4dmriinlowcontrasttissueusing2stephybriddeformableimageregistration AT deasyjoseph enhancedsuperresolutionreconstructionoft1wtimeresolved4dmriinlowcontrasttissueusing2stephybriddeformableimageregistration AT rimnerandreas enhancedsuperresolutionreconstructionoft1wtimeresolved4dmriinlowcontrasttissueusing2stephybriddeformableimageregistration AT liguang enhancedsuperresolutionreconstructionoft1wtimeresolved4dmriinlowcontrasttissueusing2stephybriddeformableimageregistration |