Cargando…
Intramedullary reaming and irrigation and antibiotic-loaded calcium sulfate implantation for the treatment of infection after intramedullary nailing: a retrospective study of 19 cases
BACKGROUND: The incidence of intramedullary infection is increasing with increased use of intramedullary fixation for long bone fractures. However, appropriate treatment for infection after intramedullary nailing is unclear. The purpose of this study was to report the results of our treatment protoc...
Autores principales: | Zhang, Hong-An, Zhou, Chun-Hao, Meng, Xiang-Qing, Fang, Jia, Qin, Cheng-He |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7594263/ https://www.ncbi.nlm.nih.gov/pubmed/33115479 http://dx.doi.org/10.1186/s12891-020-03734-z |
Ejemplares similares
-
Malrotation following reamed intramedullary nailing of closed tibial fractures
por: Jafarinejad, Adel Ebrahimpour, et al.
Publicado: (2012) -
Cardiopulmonary response to reamed intramedullary nailing of the femur with a traditional reaming system and a one-step reamer-irrigator-aspirator reaming system; an experimental study in pigs
por: Husebye, Elisabeth Ellingsen, et al.
Publicado: (2009) -
Meta-analysis of reamed versus unreamed intramedullary nailing for open tibial fractures
por: Shao, Yinchu, et al.
Publicado: (2014) -
Reamed intramedullary exchange nailing: treatment of choice of aseptic femoral shaft nonunion
por: Hierholzer, Christian, et al.
Publicado: (2014) -
Clinical Outcome of Ream Versus Unream Intramedullary Nailing for Femoral Shaft Fractures
por: Bagheri, Farshid, et al.
Publicado: (2013)