Cargando…

Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series

BACKGROUND: Previous studies on radiofrequency catheter ablation of premature ventricular complexes (PVCs) arising from the left ventricle (LV) papillary muscles (PM) show a modest procedural success rate with higher recurrence rate. Our study sought to explore the utility of using a multipolar mapp...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Chi, Wang, Jing, Niu, Hongxia, Hua, Wei, Chu, Jianmin, Zhang, Shu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7594480/
https://www.ncbi.nlm.nih.gov/pubmed/33115432
http://dx.doi.org/10.1186/s12872-020-01747-z
_version_ 1783601648562601984
author Cai, Chi
Wang, Jing
Niu, Hongxia
Hua, Wei
Chu, Jianmin
Zhang, Shu
author_facet Cai, Chi
Wang, Jing
Niu, Hongxia
Hua, Wei
Chu, Jianmin
Zhang, Shu
author_sort Cai, Chi
collection PubMed
description BACKGROUND: Previous studies on radiofrequency catheter ablation of premature ventricular complexes (PVCs) arising from the left ventricle (LV) papillary muscles (PM) show a modest procedural success rate with higher recurrence rate. Our study sought to explore the utility of using a multipolar mapping with a steerable linear duodecapolar catheter for ablating the PM PVCs. METHODS: Detailed endocardial multipolar mapping was performed using a steerable linear duodecapolar catheter in 6 consecutive PM PVCs patients with structurally normal heart. The clinical features and procedural data as well as success rate were analysed. RESULTS: LV endocardial electroanatomic mapping was performed in all patients via a retrograde aortic approach using a duodecapolar mapping catheter. All patients displayed a PVC burden with 16.2 ± 5.4%. Duodecapolar catheter mapping demonstrated highly efficiency with an average procedure time (95.8 ± 7.4 min) and fluoroscopy time (14.2 ± 1.5 min). The mean number of ablation applications points was 6.8 ± 1.9 with an average overall ablation duration of 6.1 ± 3.0 min. The values of earliest activation time during mapping using duodecapolar catheter were 37.8 ± 7.2 ms. All patients demonstrated acute successful ablation, and the PVC burden in all patients after an average follow-up of 8.5 ± 2.0 months was only 0.7%. There were no complications during the procedures and after follow-up. CONCLUSIONS: Mapping and ablation of PM PVCs using a duodecapolar catheter facilitated the identification of earliest activation potentials and pace mapping, and demonstrated a high success rate during follow-up.
format Online
Article
Text
id pubmed-7594480
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-75944802020-10-30 Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series Cai, Chi Wang, Jing Niu, Hongxia Hua, Wei Chu, Jianmin Zhang, Shu BMC Cardiovasc Disord Research Article BACKGROUND: Previous studies on radiofrequency catheter ablation of premature ventricular complexes (PVCs) arising from the left ventricle (LV) papillary muscles (PM) show a modest procedural success rate with higher recurrence rate. Our study sought to explore the utility of using a multipolar mapping with a steerable linear duodecapolar catheter for ablating the PM PVCs. METHODS: Detailed endocardial multipolar mapping was performed using a steerable linear duodecapolar catheter in 6 consecutive PM PVCs patients with structurally normal heart. The clinical features and procedural data as well as success rate were analysed. RESULTS: LV endocardial electroanatomic mapping was performed in all patients via a retrograde aortic approach using a duodecapolar mapping catheter. All patients displayed a PVC burden with 16.2 ± 5.4%. Duodecapolar catheter mapping demonstrated highly efficiency with an average procedure time (95.8 ± 7.4 min) and fluoroscopy time (14.2 ± 1.5 min). The mean number of ablation applications points was 6.8 ± 1.9 with an average overall ablation duration of 6.1 ± 3.0 min. The values of earliest activation time during mapping using duodecapolar catheter were 37.8 ± 7.2 ms. All patients demonstrated acute successful ablation, and the PVC burden in all patients after an average follow-up of 8.5 ± 2.0 months was only 0.7%. There were no complications during the procedures and after follow-up. CONCLUSIONS: Mapping and ablation of PM PVCs using a duodecapolar catheter facilitated the identification of earliest activation potentials and pace mapping, and demonstrated a high success rate during follow-up. BioMed Central 2020-10-28 /pmc/articles/PMC7594480/ /pubmed/33115432 http://dx.doi.org/10.1186/s12872-020-01747-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Cai, Chi
Wang, Jing
Niu, Hongxia
Hua, Wei
Chu, Jianmin
Zhang, Shu
Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series
title Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series
title_full Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series
title_fullStr Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series
title_full_unstemmed Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series
title_short Multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series
title_sort multipolar mapping for catheter ablation of premature ventricular complexes originating from papillary muscles in the structurally normal heart: a case series
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7594480/
https://www.ncbi.nlm.nih.gov/pubmed/33115432
http://dx.doi.org/10.1186/s12872-020-01747-z
work_keys_str_mv AT caichi multipolarmappingforcatheterablationofprematureventricularcomplexesoriginatingfrompapillarymusclesinthestructurallynormalheartacaseseries
AT wangjing multipolarmappingforcatheterablationofprematureventricularcomplexesoriginatingfrompapillarymusclesinthestructurallynormalheartacaseseries
AT niuhongxia multipolarmappingforcatheterablationofprematureventricularcomplexesoriginatingfrompapillarymusclesinthestructurallynormalheartacaseseries
AT huawei multipolarmappingforcatheterablationofprematureventricularcomplexesoriginatingfrompapillarymusclesinthestructurallynormalheartacaseseries
AT chujianmin multipolarmappingforcatheterablationofprematureventricularcomplexesoriginatingfrompapillarymusclesinthestructurallynormalheartacaseseries
AT zhangshu multipolarmappingforcatheterablationofprematureventricularcomplexesoriginatingfrompapillarymusclesinthestructurallynormalheartacaseseries