Cargando…

Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study

BACKGROUND: Most common material used for the fabrication of an implant restoration is full-ceramic crown or an all-ceramic crown. Frequent chipping of the ceramic under occlusal load has posed a great problem to the clinician and the patient. Composites have been layered over zirconia successfully...

Descripción completa

Detalles Bibliográficos
Autores principales: Shetty, Sanath K, Hasan, Mohammed Shabbir, Zahid, Mohammed, Suhaim, Karkala S, Mohammad, Fahad, Fayaz, T
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7595514/
https://www.ncbi.nlm.nih.gov/pubmed/33149515
http://dx.doi.org/10.4103/jpbs.JPBS_150_20
_version_ 1783601892893392896
author Shetty, Sanath K
Hasan, Mohammed Shabbir
Zahid, Mohammed
Suhaim, Karkala S
Mohammad, Fahad
Fayaz, T
author_facet Shetty, Sanath K
Hasan, Mohammed Shabbir
Zahid, Mohammed
Suhaim, Karkala S
Mohammad, Fahad
Fayaz, T
author_sort Shetty, Sanath K
collection PubMed
description BACKGROUND: Most common material used for the fabrication of an implant restoration is full-ceramic crown or an all-ceramic crown. Frequent chipping of the ceramic under occlusal load has posed a great problem to the clinician and the patient. Composites have been layered over zirconia successfully in the recent past to overcome this problem. This study, thus, aimed to evaluate and compare the fracture resistance and color stability of crowns obtained by layering composite over zirconia and polyetheretherketone (PEEK) copings before and after thermocycling to simulate oral environment. MATERIALS AND METHODS: A total of 40 crowns (20 per group) were obtained by layering composite of A3 shade over computer-aided design/computer-aided milling milled zirconia and PEEK copings. Thermocycling of the 10 out of the 20 crowns was performed in a thermocycler (5000 cycles, in water temperature of 5°C and 55°C with dwell time of 30s), and then they were kept in hot and cold beverages for 24h each, to simulate oral environmental conditions. After thermocycling, the crowns were divided into four groups of 10 samples each: Group Z, ZT, P, and PT. Shade evaluation of all the crowns was performed using digital shade guide (VITA Easyshade(®) Advance; VITA Zahnfabrik, Bad Säckingen, Germany) and VITAPAN classical (VITA Zahnfabrik). Fracture strength was tested for all the crowns in a universal testing machine. Fracture strength in megapascal and the applied occlusal load in kilograms were recorded. Data obtained were statistically evaluated by one-way analysis of variance and post hoc test. RESULTS: The final shade of the crowns obtained by layering A3 shade composite in the groups Z was A3, ZT was B3, P was C3, and PT was D2. The value of mean fracture strength of crowns of groups Z was 1142.3MPa, ZT was 1034.57MPa, P was 2134.64MPa, and PT was 1765.01MPa. CONCLUSION: Thermocycling affected the shade of all the crowns. The mean fracture strength of the crowns having PEEK copings was significantly higher than that of zirconia copings. Thermocycling did not have a significant effect on the mean fracture strength.
format Online
Article
Text
id pubmed-7595514
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-75955142020-11-03 Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study Shetty, Sanath K Hasan, Mohammed Shabbir Zahid, Mohammed Suhaim, Karkala S Mohammad, Fahad Fayaz, T J Pharm Bioallied Sci Original Article BACKGROUND: Most common material used for the fabrication of an implant restoration is full-ceramic crown or an all-ceramic crown. Frequent chipping of the ceramic under occlusal load has posed a great problem to the clinician and the patient. Composites have been layered over zirconia successfully in the recent past to overcome this problem. This study, thus, aimed to evaluate and compare the fracture resistance and color stability of crowns obtained by layering composite over zirconia and polyetheretherketone (PEEK) copings before and after thermocycling to simulate oral environment. MATERIALS AND METHODS: A total of 40 crowns (20 per group) were obtained by layering composite of A3 shade over computer-aided design/computer-aided milling milled zirconia and PEEK copings. Thermocycling of the 10 out of the 20 crowns was performed in a thermocycler (5000 cycles, in water temperature of 5°C and 55°C with dwell time of 30s), and then they were kept in hot and cold beverages for 24h each, to simulate oral environmental conditions. After thermocycling, the crowns were divided into four groups of 10 samples each: Group Z, ZT, P, and PT. Shade evaluation of all the crowns was performed using digital shade guide (VITA Easyshade(®) Advance; VITA Zahnfabrik, Bad Säckingen, Germany) and VITAPAN classical (VITA Zahnfabrik). Fracture strength was tested for all the crowns in a universal testing machine. Fracture strength in megapascal and the applied occlusal load in kilograms were recorded. Data obtained were statistically evaluated by one-way analysis of variance and post hoc test. RESULTS: The final shade of the crowns obtained by layering A3 shade composite in the groups Z was A3, ZT was B3, P was C3, and PT was D2. The value of mean fracture strength of crowns of groups Z was 1142.3MPa, ZT was 1034.57MPa, P was 2134.64MPa, and PT was 1765.01MPa. CONCLUSION: Thermocycling affected the shade of all the crowns. The mean fracture strength of the crowns having PEEK copings was significantly higher than that of zirconia copings. Thermocycling did not have a significant effect on the mean fracture strength. Wolters Kluwer - Medknow 2020-08 2020-08-28 /pmc/articles/PMC7595514/ /pubmed/33149515 http://dx.doi.org/10.4103/jpbs.JPBS_150_20 Text en Copyright: © 2020 Journal of Pharmacy and Bioallied Sciences http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Shetty, Sanath K
Hasan, Mohammed Shabbir
Zahid, Mohammed
Suhaim, Karkala S
Mohammad, Fahad
Fayaz, T
Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study
title Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study
title_full Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study
title_fullStr Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study
title_full_unstemmed Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study
title_short Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study
title_sort evaluation of fracture resistance and color stability of crowns obtained by layering composite over zirconia and polyetheretherketone copings before and after thermocycling to simulate oral environment: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7595514/
https://www.ncbi.nlm.nih.gov/pubmed/33149515
http://dx.doi.org/10.4103/jpbs.JPBS_150_20
work_keys_str_mv AT shettysanathk evaluationoffractureresistanceandcolorstabilityofcrownsobtainedbylayeringcompositeoverzirconiaandpolyetheretherketonecopingsbeforeandafterthermocyclingtosimulateoralenvironmentaninvitrostudy
AT hasanmohammedshabbir evaluationoffractureresistanceandcolorstabilityofcrownsobtainedbylayeringcompositeoverzirconiaandpolyetheretherketonecopingsbeforeandafterthermocyclingtosimulateoralenvironmentaninvitrostudy
AT zahidmohammed evaluationoffractureresistanceandcolorstabilityofcrownsobtainedbylayeringcompositeoverzirconiaandpolyetheretherketonecopingsbeforeandafterthermocyclingtosimulateoralenvironmentaninvitrostudy
AT suhaimkarkalas evaluationoffractureresistanceandcolorstabilityofcrownsobtainedbylayeringcompositeoverzirconiaandpolyetheretherketonecopingsbeforeandafterthermocyclingtosimulateoralenvironmentaninvitrostudy
AT mohammadfahad evaluationoffractureresistanceandcolorstabilityofcrownsobtainedbylayeringcompositeoverzirconiaandpolyetheretherketonecopingsbeforeandafterthermocyclingtosimulateoralenvironmentaninvitrostudy
AT fayazt evaluationoffractureresistanceandcolorstabilityofcrownsobtainedbylayeringcompositeoverzirconiaandpolyetheretherketonecopingsbeforeandafterthermocyclingtosimulateoralenvironmentaninvitrostudy