Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study
OBJECTIVE(S): The objective of this in vivo study was to compare and evaluate the accuracy of VDW Gold (VDW, Munich, Germany) integrated apex locator (IAL) and Root ZX Mini (J. Morita Corp., Kyoto, Japan) in two different irrigating solutions. MATERIALS AND METHODS: Forty patients who required extra...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7595532/ https://www.ncbi.nlm.nih.gov/pubmed/33149496 http://dx.doi.org/10.4103/jpbs.JPBS_122_20 |
_version_ | 1783601898603937792 |
---|---|
author | Chukka, Rakesh Reddy Bellam, Malati Devi Marukala, Narender Reddy Dinapadu, Sainath Konda, Naresh Kumar Nagilla, Jithender |
author_facet | Chukka, Rakesh Reddy Bellam, Malati Devi Marukala, Narender Reddy Dinapadu, Sainath Konda, Naresh Kumar Nagilla, Jithender |
author_sort | Chukka, Rakesh Reddy |
collection | PubMed |
description | OBJECTIVE(S): The objective of this in vivo study was to compare and evaluate the accuracy of VDW Gold (VDW, Munich, Germany) integrated apex locator (IAL) and Root ZX Mini (J. Morita Corp., Kyoto, Japan) in two different irrigating solutions. MATERIALS AND METHODS: Forty patients who required extraction were included in the study. Following local anesthesia, access opening was performed under rubber dam isolation. Initial negotiation of canal was performed using size 10 K-Files (M-Access, Dentsply Maillefer, Ballaigues, Switzerland). Cervical preparation was carried out using Rotary ProTaper SX files (Dentsply Maillefer, Ballaigues, Switzerland) under copious irrigation with 3% sodium hypochlorite. Patients were divided into two groups of 20 each: Group I (NaOCl) and Group II (CHX). The working length (WL) was determined in triplicates for each tooth using Root ZX apex locator and with S1 ProTaper rotary file in continuous motion in case of VDW Gold IAL in the presence of 3% sodium hypochlorite and 2% chlorhexidine. Therapeutic extraction was performed and WL was determined using size 15 K-Files under 20× magnification. RESULTS: The paired sample independent t test showed that there was no significant difference between the Root ZX and VDW apex locator in determining the minor foramen in NaOCl group (P = 0.234, 0.453 respectively) and CHX group (P = 0.085, 0.087) when compared with actual working length. CONCLUSION: Both the apex locators were equally effective in determining WL at 0.5 mm from the apex in presence of irrigating solutions, that is, NaOCl and chlorhexidine. |
format | Online Article Text |
id | pubmed-7595532 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-75955322020-11-03 Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study Chukka, Rakesh Reddy Bellam, Malati Devi Marukala, Narender Reddy Dinapadu, Sainath Konda, Naresh Kumar Nagilla, Jithender J Pharm Bioallied Sci Original Article OBJECTIVE(S): The objective of this in vivo study was to compare and evaluate the accuracy of VDW Gold (VDW, Munich, Germany) integrated apex locator (IAL) and Root ZX Mini (J. Morita Corp., Kyoto, Japan) in two different irrigating solutions. MATERIALS AND METHODS: Forty patients who required extraction were included in the study. Following local anesthesia, access opening was performed under rubber dam isolation. Initial negotiation of canal was performed using size 10 K-Files (M-Access, Dentsply Maillefer, Ballaigues, Switzerland). Cervical preparation was carried out using Rotary ProTaper SX files (Dentsply Maillefer, Ballaigues, Switzerland) under copious irrigation with 3% sodium hypochlorite. Patients were divided into two groups of 20 each: Group I (NaOCl) and Group II (CHX). The working length (WL) was determined in triplicates for each tooth using Root ZX apex locator and with S1 ProTaper rotary file in continuous motion in case of VDW Gold IAL in the presence of 3% sodium hypochlorite and 2% chlorhexidine. Therapeutic extraction was performed and WL was determined using size 15 K-Files under 20× magnification. RESULTS: The paired sample independent t test showed that there was no significant difference between the Root ZX and VDW apex locator in determining the minor foramen in NaOCl group (P = 0.234, 0.453 respectively) and CHX group (P = 0.085, 0.087) when compared with actual working length. CONCLUSION: Both the apex locators were equally effective in determining WL at 0.5 mm from the apex in presence of irrigating solutions, that is, NaOCl and chlorhexidine. Wolters Kluwer - Medknow 2020-08 2020-08-28 /pmc/articles/PMC7595532/ /pubmed/33149496 http://dx.doi.org/10.4103/jpbs.JPBS_122_20 Text en Copyright: © 2020 Journal of Pharmacy and Bioallied Sciences http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Chukka, Rakesh Reddy Bellam, Malati Devi Marukala, Narender Reddy Dinapadu, Sainath Konda, Naresh Kumar Nagilla, Jithender Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study |
title | Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study |
title_full | Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study |
title_fullStr | Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study |
title_full_unstemmed | Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study |
title_short | Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study |
title_sort | efficiency of an integrated apex locator in determining working length in various irrigating solutions: an in vivo study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7595532/ https://www.ncbi.nlm.nih.gov/pubmed/33149496 http://dx.doi.org/10.4103/jpbs.JPBS_122_20 |
work_keys_str_mv | AT chukkarakeshreddy efficiencyofanintegratedapexlocatorindeterminingworkinglengthinvariousirrigatingsolutionsaninvivostudy AT bellammalatidevi efficiencyofanintegratedapexlocatorindeterminingworkinglengthinvariousirrigatingsolutionsaninvivostudy AT marukalanarenderreddy efficiencyofanintegratedapexlocatorindeterminingworkinglengthinvariousirrigatingsolutionsaninvivostudy AT dinapadusainath efficiencyofanintegratedapexlocatorindeterminingworkinglengthinvariousirrigatingsolutionsaninvivostudy AT kondanareshkumar efficiencyofanintegratedapexlocatorindeterminingworkinglengthinvariousirrigatingsolutionsaninvivostudy AT nagillajithender efficiencyofanintegratedapexlocatorindeterminingworkinglengthinvariousirrigatingsolutionsaninvivostudy |