Cargando…
Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephro...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7596071/ https://www.ncbi.nlm.nih.gov/pubmed/33122830 http://dx.doi.org/10.1038/s41598-020-75672-8 |
_version_ | 1783602030423572480 |
---|---|
author | Boeri, Luca Fulgheri, Irene Palmisano, Franco Lievore, Elena Lorusso, Vito Ripa, Francesco D’Amico, Mario Spinelli, Matteo Giulio Salonia, Andrea Carrafiello, Gianpaolo Montanari, Emanuele |
author_facet | Boeri, Luca Fulgheri, Irene Palmisano, Franco Lievore, Elena Lorusso, Vito Ripa, Francesco D’Amico, Mario Spinelli, Matteo Giulio Salonia, Andrea Carrafiello, Gianpaolo Montanari, Emanuele |
author_sort | Boeri, Luca |
collection | PubMed |
description | We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephrostomy tube or ureteral catheter placement for obstructive uropathy. A radiologist drew the region of interest for quantitative measurement of the HU values in the hydronephrotic region of the affected kidney. Descriptive statistics and logistic regression models tested the predictive value of HU determination in differentiating pyonephrosis from hydronephrosis and in predicting postoperative sepsis. A HU cut-off value of 6.3 could diagnose the presence of pyonephrosis with 71.6% sensitivity and 71.5% specificity (AUC 0.76; 95%CI: 0.66–0.85). At multivariable logistic regression analysis HU ≥ 6.3 (p ≤ 0.001) was independently associated with pyonephrosis. Patients who developed sepsis had higher HU values (p ≤ 0.001) than those without sepsis. A HU cut-off value of 7.3 could diagnose the presence of sepsis with 76.5% sensitivity and 74.3% specificity (AUC 0.79; 95%CI: 0.71–0.90). At multivariable logistic regression analysis, HU ≥ 7.3 (p ≤ 0.001) was independently associated with sepsis, after accounting for clinical and laboratory parameters. Measuring HU values of the fluid of the dilated collecting system may be useful to differentiate pyonephrosis from hydronephrosis and to predict septic complications in patients with obstructive uropathy. |
format | Online Article Text |
id | pubmed-7596071 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-75960712020-10-30 Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy Boeri, Luca Fulgheri, Irene Palmisano, Franco Lievore, Elena Lorusso, Vito Ripa, Francesco D’Amico, Mario Spinelli, Matteo Giulio Salonia, Andrea Carrafiello, Gianpaolo Montanari, Emanuele Sci Rep Article We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephrostomy tube or ureteral catheter placement for obstructive uropathy. A radiologist drew the region of interest for quantitative measurement of the HU values in the hydronephrotic region of the affected kidney. Descriptive statistics and logistic regression models tested the predictive value of HU determination in differentiating pyonephrosis from hydronephrosis and in predicting postoperative sepsis. A HU cut-off value of 6.3 could diagnose the presence of pyonephrosis with 71.6% sensitivity and 71.5% specificity (AUC 0.76; 95%CI: 0.66–0.85). At multivariable logistic regression analysis HU ≥ 6.3 (p ≤ 0.001) was independently associated with pyonephrosis. Patients who developed sepsis had higher HU values (p ≤ 0.001) than those without sepsis. A HU cut-off value of 7.3 could diagnose the presence of sepsis with 76.5% sensitivity and 74.3% specificity (AUC 0.79; 95%CI: 0.71–0.90). At multivariable logistic regression analysis, HU ≥ 7.3 (p ≤ 0.001) was independently associated with sepsis, after accounting for clinical and laboratory parameters. Measuring HU values of the fluid of the dilated collecting system may be useful to differentiate pyonephrosis from hydronephrosis and to predict septic complications in patients with obstructive uropathy. Nature Publishing Group UK 2020-10-29 /pmc/articles/PMC7596071/ /pubmed/33122830 http://dx.doi.org/10.1038/s41598-020-75672-8 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Boeri, Luca Fulgheri, Irene Palmisano, Franco Lievore, Elena Lorusso, Vito Ripa, Francesco D’Amico, Mario Spinelli, Matteo Giulio Salonia, Andrea Carrafiello, Gianpaolo Montanari, Emanuele Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy |
title | Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy |
title_full | Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy |
title_fullStr | Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy |
title_full_unstemmed | Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy |
title_short | Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy |
title_sort | hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7596071/ https://www.ncbi.nlm.nih.gov/pubmed/33122830 http://dx.doi.org/10.1038/s41598-020-75672-8 |
work_keys_str_mv | AT boeriluca hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT fulgheriirene hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT palmisanofranco hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT lievoreelena hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT lorussovito hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT ripafrancesco hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT damicomario hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT spinellimatteogiulio hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT saloniaandrea hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT carrafiellogianpaolo hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy AT montanariemanuele hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy |