Cargando…

Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy

We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephro...

Descripción completa

Detalles Bibliográficos
Autores principales: Boeri, Luca, Fulgheri, Irene, Palmisano, Franco, Lievore, Elena, Lorusso, Vito, Ripa, Francesco, D’Amico, Mario, Spinelli, Matteo Giulio, Salonia, Andrea, Carrafiello, Gianpaolo, Montanari, Emanuele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7596071/
https://www.ncbi.nlm.nih.gov/pubmed/33122830
http://dx.doi.org/10.1038/s41598-020-75672-8
_version_ 1783602030423572480
author Boeri, Luca
Fulgheri, Irene
Palmisano, Franco
Lievore, Elena
Lorusso, Vito
Ripa, Francesco
D’Amico, Mario
Spinelli, Matteo Giulio
Salonia, Andrea
Carrafiello, Gianpaolo
Montanari, Emanuele
author_facet Boeri, Luca
Fulgheri, Irene
Palmisano, Franco
Lievore, Elena
Lorusso, Vito
Ripa, Francesco
D’Amico, Mario
Spinelli, Matteo Giulio
Salonia, Andrea
Carrafiello, Gianpaolo
Montanari, Emanuele
author_sort Boeri, Luca
collection PubMed
description We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephrostomy tube or ureteral catheter placement for obstructive uropathy. A radiologist drew the region of interest for quantitative measurement of the HU values in the hydronephrotic region of the affected kidney. Descriptive statistics and logistic regression models tested the predictive value of HU determination in differentiating pyonephrosis from hydronephrosis and in predicting postoperative sepsis. A HU cut-off value of 6.3 could diagnose the presence of pyonephrosis with 71.6% sensitivity and 71.5% specificity (AUC 0.76; 95%CI: 0.66–0.85). At multivariable logistic regression analysis HU ≥ 6.3 (p ≤ 0.001) was independently associated with pyonephrosis. Patients who developed sepsis had higher HU values (p ≤ 0.001) than those without sepsis. A HU cut-off value of 7.3 could diagnose the presence of sepsis with 76.5% sensitivity and 74.3% specificity (AUC 0.79; 95%CI: 0.71–0.90). At multivariable logistic regression analysis, HU ≥ 7.3 (p ≤ 0.001) was independently associated with sepsis, after accounting for clinical and laboratory parameters. Measuring HU values of the fluid of the dilated collecting system may be useful to differentiate pyonephrosis from hydronephrosis and to predict septic complications in patients with obstructive uropathy.
format Online
Article
Text
id pubmed-7596071
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-75960712020-10-30 Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy Boeri, Luca Fulgheri, Irene Palmisano, Franco Lievore, Elena Lorusso, Vito Ripa, Francesco D’Amico, Mario Spinelli, Matteo Giulio Salonia, Andrea Carrafiello, Gianpaolo Montanari, Emanuele Sci Rep Article We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephrostomy tube or ureteral catheter placement for obstructive uropathy. A radiologist drew the region of interest for quantitative measurement of the HU values in the hydronephrotic region of the affected kidney. Descriptive statistics and logistic regression models tested the predictive value of HU determination in differentiating pyonephrosis from hydronephrosis and in predicting postoperative sepsis. A HU cut-off value of 6.3 could diagnose the presence of pyonephrosis with 71.6% sensitivity and 71.5% specificity (AUC 0.76; 95%CI: 0.66–0.85). At multivariable logistic regression analysis HU ≥ 6.3 (p ≤ 0.001) was independently associated with pyonephrosis. Patients who developed sepsis had higher HU values (p ≤ 0.001) than those without sepsis. A HU cut-off value of 7.3 could diagnose the presence of sepsis with 76.5% sensitivity and 74.3% specificity (AUC 0.79; 95%CI: 0.71–0.90). At multivariable logistic regression analysis, HU ≥ 7.3 (p ≤ 0.001) was independently associated with sepsis, after accounting for clinical and laboratory parameters. Measuring HU values of the fluid of the dilated collecting system may be useful to differentiate pyonephrosis from hydronephrosis and to predict septic complications in patients with obstructive uropathy. Nature Publishing Group UK 2020-10-29 /pmc/articles/PMC7596071/ /pubmed/33122830 http://dx.doi.org/10.1038/s41598-020-75672-8 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Boeri, Luca
Fulgheri, Irene
Palmisano, Franco
Lievore, Elena
Lorusso, Vito
Ripa, Francesco
D’Amico, Mario
Spinelli, Matteo Giulio
Salonia, Andrea
Carrafiello, Gianpaolo
Montanari, Emanuele
Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
title Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
title_full Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
title_fullStr Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
title_full_unstemmed Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
title_short Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
title_sort hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7596071/
https://www.ncbi.nlm.nih.gov/pubmed/33122830
http://dx.doi.org/10.1038/s41598-020-75672-8
work_keys_str_mv AT boeriluca hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT fulgheriirene hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT palmisanofranco hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT lievoreelena hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT lorussovito hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT ripafrancesco hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT damicomario hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT spinellimatteogiulio hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT saloniaandrea hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT carrafiellogianpaolo hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy
AT montanariemanuele hounsfieldunitattenuationvaluecandifferentiatepyonephrosisfromhydronephrosisandpredictsepticcomplicationsinpatientswithobstructiveuropathy