Cargando…

Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study

BACKGROUND: Short stem total hip arthroplasty (SHA) preserves femoral bone stock and is supposed to provide a more natural load transfer compared to standard stem total hip arthroplasty (THA). As comparative biomechanical reference data are rare we used a finite element analysis (FEA) approach to co...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Shuang G., Chevalier, Yan, Liu, Fanxiao, Hua, Xingyi, Schreiner, Anna, Jansson, Volkmar, Schmidutz, Florian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597026/
https://www.ncbi.nlm.nih.gov/pubmed/33121506
http://dx.doi.org/10.1186/s13018-020-02027-4
_version_ 1783602242652209152
author Yan, Shuang G.
Chevalier, Yan
Liu, Fanxiao
Hua, Xingyi
Schreiner, Anna
Jansson, Volkmar
Schmidutz, Florian
author_facet Yan, Shuang G.
Chevalier, Yan
Liu, Fanxiao
Hua, Xingyi
Schreiner, Anna
Jansson, Volkmar
Schmidutz, Florian
author_sort Yan, Shuang G.
collection PubMed
description BACKGROUND: Short stem total hip arthroplasty (SHA) preserves femoral bone stock and is supposed to provide a more natural load transfer compared to standard stem total hip arthroplasty (THA). As comparative biomechanical reference data are rare we used a finite element analysis (FEA) approach to compare cortical load transfer after implantations of a metaphyseal anchoring short and standard stem in native biomechanical femora. METHODS: The subject specific finite element models of biomechanical femora, one native and two with implanted metaphyseal anchoring SHA (Metha, B. Braun Aesculap) and standard THA (CLS, Zimmer-Biomet), were generated from computed tomography datasets. The loading configuration was performed with an axial force of 1400 N. Von Mises stress was used to investigate the change of cortical stress distribution. RESULTS: Compared to the native femur, a considerable reduction of cortical stress was recorded after implantation of SHA and standard THA. The SHA showed less reduction proximally with a significant higher metaphyseal cortical stress compared to standard THA. Moreover, the highest peak stresses were observed metaphyseal for the SHA stem while for the standard THA high stress pattern was observed more distally. CONCLUSIONS: Both, short and standard THA, cause unloading of the proximal femur. However, the metaphyseal anchoring SHA features a clearly favorable pattern in terms of a lower reduction proximally and improved metaphyseal loading, while standard THA shows a higher proximal unloading and more distal load transfer. These load patterns implicate a reduced stress shielding proximally for metaphyseal anchoring SHA stems and might be able to translate in a better bone preservation.
format Online
Article
Text
id pubmed-7597026
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-75970262020-11-02 Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study Yan, Shuang G. Chevalier, Yan Liu, Fanxiao Hua, Xingyi Schreiner, Anna Jansson, Volkmar Schmidutz, Florian J Orthop Surg Res Research Article BACKGROUND: Short stem total hip arthroplasty (SHA) preserves femoral bone stock and is supposed to provide a more natural load transfer compared to standard stem total hip arthroplasty (THA). As comparative biomechanical reference data are rare we used a finite element analysis (FEA) approach to compare cortical load transfer after implantations of a metaphyseal anchoring short and standard stem in native biomechanical femora. METHODS: The subject specific finite element models of biomechanical femora, one native and two with implanted metaphyseal anchoring SHA (Metha, B. Braun Aesculap) and standard THA (CLS, Zimmer-Biomet), were generated from computed tomography datasets. The loading configuration was performed with an axial force of 1400 N. Von Mises stress was used to investigate the change of cortical stress distribution. RESULTS: Compared to the native femur, a considerable reduction of cortical stress was recorded after implantation of SHA and standard THA. The SHA showed less reduction proximally with a significant higher metaphyseal cortical stress compared to standard THA. Moreover, the highest peak stresses were observed metaphyseal for the SHA stem while for the standard THA high stress pattern was observed more distally. CONCLUSIONS: Both, short and standard THA, cause unloading of the proximal femur. However, the metaphyseal anchoring SHA features a clearly favorable pattern in terms of a lower reduction proximally and improved metaphyseal loading, while standard THA shows a higher proximal unloading and more distal load transfer. These load patterns implicate a reduced stress shielding proximally for metaphyseal anchoring SHA stems and might be able to translate in a better bone preservation. BioMed Central 2020-10-29 /pmc/articles/PMC7597026/ /pubmed/33121506 http://dx.doi.org/10.1186/s13018-020-02027-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Yan, Shuang G.
Chevalier, Yan
Liu, Fanxiao
Hua, Xingyi
Schreiner, Anna
Jansson, Volkmar
Schmidutz, Florian
Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
title Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
title_full Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
title_fullStr Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
title_full_unstemmed Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
title_short Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
title_sort metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597026/
https://www.ncbi.nlm.nih.gov/pubmed/33121506
http://dx.doi.org/10.1186/s13018-020-02027-4
work_keys_str_mv AT yanshuangg metaphysealanchoringshortstemhiparthroplastyprovidesamorephysiologicalloadtransferacomparativefiniteelementanalysisstudy
AT chevalieryan metaphysealanchoringshortstemhiparthroplastyprovidesamorephysiologicalloadtransferacomparativefiniteelementanalysisstudy
AT liufanxiao metaphysealanchoringshortstemhiparthroplastyprovidesamorephysiologicalloadtransferacomparativefiniteelementanalysisstudy
AT huaxingyi metaphysealanchoringshortstemhiparthroplastyprovidesamorephysiologicalloadtransferacomparativefiniteelementanalysisstudy
AT schreineranna metaphysealanchoringshortstemhiparthroplastyprovidesamorephysiologicalloadtransferacomparativefiniteelementanalysisstudy
AT janssonvolkmar metaphysealanchoringshortstemhiparthroplastyprovidesamorephysiologicalloadtransferacomparativefiniteelementanalysisstudy
AT schmidutzflorian metaphysealanchoringshortstemhiparthroplastyprovidesamorephysiologicalloadtransferacomparativefiniteelementanalysisstudy