Cargando…
Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report
INTRODUCTION: We aimed to report the clinical evaluation results of gait training with the Honda Walking Assist Device(®) (HWAT) in a patient with spinal cord injury (SCI). PATIENTS AND METHODS: A 63-year-old male with SCI (grade D on the American Spinal Injury Association Impairment Scale) underwen...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597562/ https://www.ncbi.nlm.nih.gov/pubmed/33194254 http://dx.doi.org/10.1177/2151459320956960 |
_version_ | 1783602388773371904 |
---|---|
author | Yoshikawa, Kenichi Mutsuzaki, Hirotaka Koseki, Kazunori Endo, Yusuke Hashizume, Yuko Nakazawa, Ryo Aoyama, Toshiyuki Yozu, Arito Kohno, Yutaka |
author_facet | Yoshikawa, Kenichi Mutsuzaki, Hirotaka Koseki, Kazunori Endo, Yusuke Hashizume, Yuko Nakazawa, Ryo Aoyama, Toshiyuki Yozu, Arito Kohno, Yutaka |
author_sort | Yoshikawa, Kenichi |
collection | PubMed |
description | INTRODUCTION: We aimed to report the clinical evaluation results of gait training with the Honda Walking Assist Device(®) (HWAT) in a patient with spinal cord injury (SCI). PATIENTS AND METHODS: A 63-year-old male with SCI (grade D on the American Spinal Injury Association Impairment Scale) underwent 20 HWAT sessions over 4 weeks. The self-selected walking speed (SWS), mean step length, cadence, 6-minute walking test (6MWT), Walking Index for SCI score, SCI Functional Ambulation Inventory gait score, American Spinal Injury Association Impairment Scale grade, neurological level, upper and lower extremity motor scores, modified Ashworth Scale, Penn Spasm Frequency Scale, and Spinal Cord Independence Measure version III were measured on admission, at the start of HWAT, at 2 and 4 weeks post-HWAT, and at discharge. Three-dimensional kinematic gait analysis and electromyographic assessments were performed before and after HWAT. RESULTS: The patient safely completed 20 HWAT sessions. We found improvements above the clinically meaningful difference in SWS and 6MWT as well as increased hip extension, ankle plantar- and dorsi-flexion range of motion and increased hip extensor, abductor, adductor, and ankle plantar flexor muscle activity. DISCUSSION: The SWS improved more markedly during the HWAT intervention, exceeding the minimal clinically important difference (0.10 to 0.15 m/s) in walking speed for people with SCI until discharge. Moreover, the 6MWT results at 2 weeks after the start of HWAT exceeded the cutoff value (472.5 m) for community ambulation and remained at a similar value at discharge. CONCLUSION: The walking distance (6MWT) and the walking speed (SWS) both demonstrated clinically important improvements following 20 treatment sessions which included HWAT. |
format | Online Article Text |
id | pubmed-7597562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-75975622020-11-12 Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report Yoshikawa, Kenichi Mutsuzaki, Hirotaka Koseki, Kazunori Endo, Yusuke Hashizume, Yuko Nakazawa, Ryo Aoyama, Toshiyuki Yozu, Arito Kohno, Yutaka Geriatr Orthop Surg Rehabil Case Report INTRODUCTION: We aimed to report the clinical evaluation results of gait training with the Honda Walking Assist Device(®) (HWAT) in a patient with spinal cord injury (SCI). PATIENTS AND METHODS: A 63-year-old male with SCI (grade D on the American Spinal Injury Association Impairment Scale) underwent 20 HWAT sessions over 4 weeks. The self-selected walking speed (SWS), mean step length, cadence, 6-minute walking test (6MWT), Walking Index for SCI score, SCI Functional Ambulation Inventory gait score, American Spinal Injury Association Impairment Scale grade, neurological level, upper and lower extremity motor scores, modified Ashworth Scale, Penn Spasm Frequency Scale, and Spinal Cord Independence Measure version III were measured on admission, at the start of HWAT, at 2 and 4 weeks post-HWAT, and at discharge. Three-dimensional kinematic gait analysis and electromyographic assessments were performed before and after HWAT. RESULTS: The patient safely completed 20 HWAT sessions. We found improvements above the clinically meaningful difference in SWS and 6MWT as well as increased hip extension, ankle plantar- and dorsi-flexion range of motion and increased hip extensor, abductor, adductor, and ankle plantar flexor muscle activity. DISCUSSION: The SWS improved more markedly during the HWAT intervention, exceeding the minimal clinically important difference (0.10 to 0.15 m/s) in walking speed for people with SCI until discharge. Moreover, the 6MWT results at 2 weeks after the start of HWAT exceeded the cutoff value (472.5 m) for community ambulation and remained at a similar value at discharge. CONCLUSION: The walking distance (6MWT) and the walking speed (SWS) both demonstrated clinically important improvements following 20 treatment sessions which included HWAT. SAGE Publications 2020-10-28 /pmc/articles/PMC7597562/ /pubmed/33194254 http://dx.doi.org/10.1177/2151459320956960 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Case Report Yoshikawa, Kenichi Mutsuzaki, Hirotaka Koseki, Kazunori Endo, Yusuke Hashizume, Yuko Nakazawa, Ryo Aoyama, Toshiyuki Yozu, Arito Kohno, Yutaka Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report |
title | Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report |
title_full | Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report |
title_fullStr | Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report |
title_full_unstemmed | Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report |
title_short | Gait Training Using a Wearable Robotic Device for Non-Traumatic Spinal Cord Injury: A Case Report |
title_sort | gait training using a wearable robotic device for non-traumatic spinal cord injury: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597562/ https://www.ncbi.nlm.nih.gov/pubmed/33194254 http://dx.doi.org/10.1177/2151459320956960 |
work_keys_str_mv | AT yoshikawakenichi gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT mutsuzakihirotaka gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT kosekikazunori gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT endoyusuke gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT hashizumeyuko gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT nakazawaryo gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT aoyamatoshiyuki gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT yozuarito gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport AT kohnoyutaka gaittrainingusingawearableroboticdevicefornontraumaticspinalcordinjuryacasereport |