Cargando…

Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects

PURPOSE: We sought to establish normative ranges of the ganglion cell-inner plexiform layer (GCIPL) thickness using spectral-domain optical coherence tomography in Korean elderly individuals and to identify factors that influence GCIPL thickness. METHODS: We conducted a retrospective, observational...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Yun Ji, Yoo, Yung Ju, Han, Sang Beom
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Ophthalmological Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597617/
https://www.ncbi.nlm.nih.gov/pubmed/33099563
http://dx.doi.org/10.3341/kjo.2020.0013
_version_ 1783602401602699264
author Lee, Yun Ji
Yoo, Yung Ju
Han, Sang Beom
author_facet Lee, Yun Ji
Yoo, Yung Ju
Han, Sang Beom
author_sort Lee, Yun Ji
collection PubMed
description PURPOSE: We sought to establish normative ranges of the ganglion cell-inner plexiform layer (GCIPL) thickness using spectral-domain optical coherence tomography in Korean elderly individuals and to identify factors that influence GCIPL thickness. METHODS: We conducted a retrospective, observational study of 114 healthy subjects (75 years old or older) who underwent comprehensive ophthalmic examinations at a single institution. GCIPL thickness was measured with the Cirrus spectral-domain optical coherence tomography system and automatic segmentation. Subjects were divided into two age groups: those younger than 80 years and those 80 years or older, respectively. A cross-sectional analysis was adopted to evaluate associations of GCIPL thickness with sex, age, intraocular pressure, optic disc rim area, axial length, spherical equivalent (SE) refractive errors, astigmatism, and body mass index. RESULTS: The average and minimum GCIPL thicknesses were 80.3 ± 5.6 µm and 76.3 ± 5.9 µm, respectively. The GCIPL thickness was significantly lower in the older group than in the younger group in the inferior, inferonasal, and inferotemporal segments (all p < 0.01). A thinner average GCIPL thickness was strongly associated with increasing age (β = -2.87, p = 0.021) and thinner circumpapillary retinal nerve fiber layer thickness (β = 2.87, p < 0.001) in all segments. CONCLUSIONS: GCIPL thickness decreased with age globally and in all segments, even after 75 years of age. Thinner GCIPL was associated with older age and thinner circumpapillary retinal nerve fiber layer. Age-related changes should be considered when using GCIPL thickness to assess glaucoma and other optic neuropathies characterized by retinal ganglion cell loss.
format Online
Article
Text
id pubmed-7597617
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-75976172020-11-03 Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects Lee, Yun Ji Yoo, Yung Ju Han, Sang Beom Korean J Ophthalmol Original Article PURPOSE: We sought to establish normative ranges of the ganglion cell-inner plexiform layer (GCIPL) thickness using spectral-domain optical coherence tomography in Korean elderly individuals and to identify factors that influence GCIPL thickness. METHODS: We conducted a retrospective, observational study of 114 healthy subjects (75 years old or older) who underwent comprehensive ophthalmic examinations at a single institution. GCIPL thickness was measured with the Cirrus spectral-domain optical coherence tomography system and automatic segmentation. Subjects were divided into two age groups: those younger than 80 years and those 80 years or older, respectively. A cross-sectional analysis was adopted to evaluate associations of GCIPL thickness with sex, age, intraocular pressure, optic disc rim area, axial length, spherical equivalent (SE) refractive errors, astigmatism, and body mass index. RESULTS: The average and minimum GCIPL thicknesses were 80.3 ± 5.6 µm and 76.3 ± 5.9 µm, respectively. The GCIPL thickness was significantly lower in the older group than in the younger group in the inferior, inferonasal, and inferotemporal segments (all p < 0.01). A thinner average GCIPL thickness was strongly associated with increasing age (β = -2.87, p = 0.021) and thinner circumpapillary retinal nerve fiber layer thickness (β = 2.87, p < 0.001) in all segments. CONCLUSIONS: GCIPL thickness decreased with age globally and in all segments, even after 75 years of age. Thinner GCIPL was associated with older age and thinner circumpapillary retinal nerve fiber layer. Age-related changes should be considered when using GCIPL thickness to assess glaucoma and other optic neuropathies characterized by retinal ganglion cell loss. Korean Ophthalmological Society 2020-10 2020-10-05 /pmc/articles/PMC7597617/ /pubmed/33099563 http://dx.doi.org/10.3341/kjo.2020.0013 Text en Copyright © 2020 Korean Ophthalmological Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Yun Ji
Yoo, Yung Ju
Han, Sang Beom
Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects
title Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects
title_full Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects
title_fullStr Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects
title_full_unstemmed Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects
title_short Age-related Changes of Macular Ganglion Cell-inner Plexiform Layer Thickness in Korean Elderly Subjects
title_sort age-related changes of macular ganglion cell-inner plexiform layer thickness in korean elderly subjects
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597617/
https://www.ncbi.nlm.nih.gov/pubmed/33099563
http://dx.doi.org/10.3341/kjo.2020.0013
work_keys_str_mv AT leeyunji agerelatedchangesofmacularganglioncellinnerplexiformlayerthicknessinkoreanelderlysubjects
AT yooyungju agerelatedchangesofmacularganglioncellinnerplexiformlayerthicknessinkoreanelderlysubjects
AT hansangbeom agerelatedchangesofmacularganglioncellinnerplexiformlayerthicknessinkoreanelderlysubjects