915 MHz microwave-assisted laparoscopic partial splenectomy: A case series
BACKGROUND: Haemorrhage during the splenic parenchyma transection is a major threat for laparoscopic partial splenectomy (LPS). We here aim to evaluate the feasibility and safety of pre-coagulation of a 915 MHz microwave (MW) device during LPS. MATERIALS AND METHODS: Data of four patients admitted t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597887/ https://www.ncbi.nlm.nih.gov/pubmed/31929223 http://dx.doi.org/10.4103/jmas.JMAS_32_19 |
_version_ | 1783602464860143616 |
---|---|
author | Zhang, Qiyi Tian, Yang Duan, Jixuan Gao, Zhenzhen Wang, Weilin Yan, Sheng |
author_facet | Zhang, Qiyi Tian, Yang Duan, Jixuan Gao, Zhenzhen Wang, Weilin Yan, Sheng |
author_sort | Zhang, Qiyi |
collection | PubMed |
description | BACKGROUND: Haemorrhage during the splenic parenchyma transection is a major threat for laparoscopic partial splenectomy (LPS). We here aim to evaluate the feasibility and safety of pre-coagulation of a 915 MHz microwave (MW) device during LPS. MATERIALS AND METHODS: Data of four patients admitted to our hospital between November 2016 and July 2018 were retrospectively analysed. The mean age was 24 years (range, 19–33); they all diagnosed with splenic unifocal lesion with a mean diameter of 4.6 cm (ranged from 3.7 to 6 cm) and underwent LPS with pre-coagulation of a 915 MHz MW. RESULTS: The LPS with pre-coagulation was successfully resulted in complete resection without microscopic residual tumour (R0 resection). The mean operative time was 205 min, and the minimum blood loss was at the range of 30–50 ml. No complication was observed, and the length of stay in hospital was varied from 5 to 10 days. CONCLUSION: Based on our observation, pre-coagulation of a 915 MHz MW during LPS is a safe and efficient technique. More studies are required before applying extensively. |
format | Online Article Text |
id | pubmed-7597887 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-75978872020-11-03 915 MHz microwave-assisted laparoscopic partial splenectomy: A case series Zhang, Qiyi Tian, Yang Duan, Jixuan Gao, Zhenzhen Wang, Weilin Yan, Sheng J Minim Access Surg How I Do It BACKGROUND: Haemorrhage during the splenic parenchyma transection is a major threat for laparoscopic partial splenectomy (LPS). We here aim to evaluate the feasibility and safety of pre-coagulation of a 915 MHz microwave (MW) device during LPS. MATERIALS AND METHODS: Data of four patients admitted to our hospital between November 2016 and July 2018 were retrospectively analysed. The mean age was 24 years (range, 19–33); they all diagnosed with splenic unifocal lesion with a mean diameter of 4.6 cm (ranged from 3.7 to 6 cm) and underwent LPS with pre-coagulation of a 915 MHz MW. RESULTS: The LPS with pre-coagulation was successfully resulted in complete resection without microscopic residual tumour (R0 resection). The mean operative time was 205 min, and the minimum blood loss was at the range of 30–50 ml. No complication was observed, and the length of stay in hospital was varied from 5 to 10 days. CONCLUSION: Based on our observation, pre-coagulation of a 915 MHz MW during LPS is a safe and efficient technique. More studies are required before applying extensively. Wolters Kluwer - Medknow 2020 2020-01-03 /pmc/articles/PMC7597887/ /pubmed/31929223 http://dx.doi.org/10.4103/jmas.JMAS_32_19 Text en Copyright: © 2020 Journal of Minimal Access Surgery http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | How I Do It Zhang, Qiyi Tian, Yang Duan, Jixuan Gao, Zhenzhen Wang, Weilin Yan, Sheng 915 MHz microwave-assisted laparoscopic partial splenectomy: A case series |
title | 915 MHz microwave-assisted laparoscopic partial splenectomy: A case series |
title_full | 915 MHz microwave-assisted laparoscopic partial splenectomy: A case series |
title_fullStr | 915 MHz microwave-assisted laparoscopic partial splenectomy: A case series |
title_full_unstemmed | 915 MHz microwave-assisted laparoscopic partial splenectomy: A case series |
title_short | 915 MHz microwave-assisted laparoscopic partial splenectomy: A case series |
title_sort | 915 mhz microwave-assisted laparoscopic partial splenectomy: a case series |
topic | How I Do It |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7597887/ https://www.ncbi.nlm.nih.gov/pubmed/31929223 http://dx.doi.org/10.4103/jmas.JMAS_32_19 |
work_keys_str_mv | AT zhangqiyi 915mhzmicrowaveassistedlaparoscopicpartialsplenectomyacaseseries AT tianyang 915mhzmicrowaveassistedlaparoscopicpartialsplenectomyacaseseries AT duanjixuan 915mhzmicrowaveassistedlaparoscopicpartialsplenectomyacaseseries AT gaozhenzhen 915mhzmicrowaveassistedlaparoscopicpartialsplenectomyacaseseries AT wangweilin 915mhzmicrowaveassistedlaparoscopicpartialsplenectomyacaseseries AT yansheng 915mhzmicrowaveassistedlaparoscopicpartialsplenectomyacaseseries |