A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography
Laboratory X-ray diffraction contrast tomography (LabDCT) has recently been developed as a powerful technique for non-destructive mapping of grain microstructures in bulk materials. As the grain reconstruction relies on segmentation of diffraction spots, it is essential to understand the physics of...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7598096/ https://www.ncbi.nlm.nih.gov/pubmed/33125349 http://dx.doi.org/10.1107/S2053273320010852 |
_version_ | 1783602506532651008 |
---|---|
author | Fang, H. Juul Jensen, D. Zhang, Y. |
author_facet | Fang, H. Juul Jensen, D. Zhang, Y. |
author_sort | Fang, H. |
collection | PubMed |
description | Laboratory X-ray diffraction contrast tomography (LabDCT) has recently been developed as a powerful technique for non-destructive mapping of grain microstructures in bulk materials. As the grain reconstruction relies on segmentation of diffraction spots, it is essential to understand the physics of the diffraction process and resolve all the spot features in detail. To this aim, a flexible and standalone forward simulation model has been developed to compute the diffraction projections from polycrystalline samples with any crystal structure. The accuracy of the forward simulation model is demonstrated by good agreements in grain orientations, boundary positions and shapes between a virtual input structure and that reconstructed based on the forward simulated diffraction projections of the input structure. Further experimental verification is made by comparisons of diffraction spots between simulations and experiments for a partially recrystallized Al sample, where a satisfactory agreement is found for the spot positions, sizes and intensities. Finally, applications of this model to analyze specific spot features are presented. |
format | Online Article Text |
id | pubmed-7598096 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-75980962020-11-17 A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography Fang, H. Juul Jensen, D. Zhang, Y. Acta Crystallogr A Found Adv Research Papers Laboratory X-ray diffraction contrast tomography (LabDCT) has recently been developed as a powerful technique for non-destructive mapping of grain microstructures in bulk materials. As the grain reconstruction relies on segmentation of diffraction spots, it is essential to understand the physics of the diffraction process and resolve all the spot features in detail. To this aim, a flexible and standalone forward simulation model has been developed to compute the diffraction projections from polycrystalline samples with any crystal structure. The accuracy of the forward simulation model is demonstrated by good agreements in grain orientations, boundary positions and shapes between a virtual input structure and that reconstructed based on the forward simulated diffraction projections of the input structure. Further experimental verification is made by comparisons of diffraction spots between simulations and experiments for a partially recrystallized Al sample, where a satisfactory agreement is found for the spot positions, sizes and intensities. Finally, applications of this model to analyze specific spot features are presented. International Union of Crystallography 2020-09-18 /pmc/articles/PMC7598096/ /pubmed/33125349 http://dx.doi.org/10.1107/S2053273320010852 Text en © H. Fang et al. 2020 http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Research Papers Fang, H. Juul Jensen, D. Zhang, Y. A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography |
title | A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography |
title_full | A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography |
title_fullStr | A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography |
title_full_unstemmed | A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography |
title_short | A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography |
title_sort | flexible and standalone forward simulation model for laboratory x-ray diffraction contrast tomography |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7598096/ https://www.ncbi.nlm.nih.gov/pubmed/33125349 http://dx.doi.org/10.1107/S2053273320010852 |
work_keys_str_mv | AT fangh aflexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography AT juuljensend aflexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography AT zhangy aflexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography AT fangh flexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography AT juuljensend flexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography AT zhangy flexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography |