Cargando…

A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography

Laboratory X-ray diffraction contrast tomography (LabDCT) has recently been developed as a powerful technique for non-destructive mapping of grain microstructures in bulk materials. As the grain reconstruction relies on segmentation of diffraction spots, it is essential to understand the physics of...

Descripción completa

Detalles Bibliográficos
Autores principales: Fang, H., Juul Jensen, D., Zhang, Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7598096/
https://www.ncbi.nlm.nih.gov/pubmed/33125349
http://dx.doi.org/10.1107/S2053273320010852
_version_ 1783602506532651008
author Fang, H.
Juul Jensen, D.
Zhang, Y.
author_facet Fang, H.
Juul Jensen, D.
Zhang, Y.
author_sort Fang, H.
collection PubMed
description Laboratory X-ray diffraction contrast tomography (LabDCT) has recently been developed as a powerful technique for non-destructive mapping of grain microstructures in bulk materials. As the grain reconstruction relies on segmentation of diffraction spots, it is essential to understand the physics of the diffraction process and resolve all the spot features in detail. To this aim, a flexible and standalone forward simulation model has been developed to compute the diffraction projections from polycrystalline samples with any crystal structure. The accuracy of the forward simulation model is demonstrated by good agreements in grain orientations, boundary positions and shapes between a virtual input structure and that reconstructed based on the forward simulated diffraction projections of the input structure. Further experimental verification is made by comparisons of diffraction spots between simulations and experiments for a partially recrystallized Al sample, where a satisfactory agreement is found for the spot positions, sizes and intensities. Finally, applications of this model to analyze specific spot features are presented.
format Online
Article
Text
id pubmed-7598096
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-75980962020-11-17 A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography Fang, H. Juul Jensen, D. Zhang, Y. Acta Crystallogr A Found Adv Research Papers Laboratory X-ray diffraction contrast tomography (LabDCT) has recently been developed as a powerful technique for non-destructive mapping of grain microstructures in bulk materials. As the grain reconstruction relies on segmentation of diffraction spots, it is essential to understand the physics of the diffraction process and resolve all the spot features in detail. To this aim, a flexible and standalone forward simulation model has been developed to compute the diffraction projections from polycrystalline samples with any crystal structure. The accuracy of the forward simulation model is demonstrated by good agreements in grain orientations, boundary positions and shapes between a virtual input structure and that reconstructed based on the forward simulated diffraction projections of the input structure. Further experimental verification is made by comparisons of diffraction spots between simulations and experiments for a partially recrystallized Al sample, where a satisfactory agreement is found for the spot positions, sizes and intensities. Finally, applications of this model to analyze specific spot features are presented. International Union of Crystallography 2020-09-18 /pmc/articles/PMC7598096/ /pubmed/33125349 http://dx.doi.org/10.1107/S2053273320010852 Text en © H. Fang et al. 2020 http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/4.0/
spellingShingle Research Papers
Fang, H.
Juul Jensen, D.
Zhang, Y.
A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography
title A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography
title_full A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography
title_fullStr A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography
title_full_unstemmed A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography
title_short A flexible and standalone forward simulation model for laboratory X-ray diffraction contrast tomography
title_sort flexible and standalone forward simulation model for laboratory x-ray diffraction contrast tomography
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7598096/
https://www.ncbi.nlm.nih.gov/pubmed/33125349
http://dx.doi.org/10.1107/S2053273320010852
work_keys_str_mv AT fangh aflexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography
AT juuljensend aflexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography
AT zhangy aflexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography
AT fangh flexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography
AT juuljensend flexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography
AT zhangy flexibleandstandaloneforwardsimulationmodelforlaboratoryxraydiffractioncontrasttomography