Cargando…

Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers

We present a wafer-level vacuum-packaged (WLVP) translatory micro-electro-mechanical system (MEMS) actuator developed for a compact near-infrared-Fourier transform spectrometer (NIR-FTS) with 800–2500 nm spectral bandwidth and signal-nose-ratio (SNR) > 1000 in the smaller bandwidth range (1200–25...

Descripción completa

Detalles Bibliográficos
Autores principales: Sandner, Thilo, Gaumont, Eric, Graßhoff, Thomas, Rieck, Andreas, Seifert, Tobias, Auböck, Gerald, Grahmann, Jan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7598276/
https://www.ncbi.nlm.nih.gov/pubmed/32977467
http://dx.doi.org/10.3390/mi11100883
_version_ 1783602559461621760
author Sandner, Thilo
Gaumont, Eric
Graßhoff, Thomas
Rieck, Andreas
Seifert, Tobias
Auböck, Gerald
Grahmann, Jan
author_facet Sandner, Thilo
Gaumont, Eric
Graßhoff, Thomas
Rieck, Andreas
Seifert, Tobias
Auböck, Gerald
Grahmann, Jan
author_sort Sandner, Thilo
collection PubMed
description We present a wafer-level vacuum-packaged (WLVP) translatory micro-electro-mechanical system (MEMS) actuator developed for a compact near-infrared-Fourier transform spectrometer (NIR-FTS) with 800–2500 nm spectral bandwidth and signal-nose-ratio (SNR) > 1000 in the smaller bandwidth range (1200–2500 nm) for 1 s measuring time. Although monolithic, highly miniaturized MEMS NIR-FTSs exist today, we follow a classical optical FT instrumentation using a resonant MEMS mirror of 5 mm diameter with precise out-of-plane translatory oscillation for optical path-length modulation. Compared to highly miniaturized MEMS NIR-FTS, the present concept features higher optical throughput and resolution, as well as mechanical robustness and insensitivity to vibration and mechanical shock, compared to conventional FTS mirror drives. The large-stroke MEMS design uses a fully symmetrical four-pantograph suspension, avoiding problems with tilting and parasitic modes. Due to significant gas damping, a permanent vacuum of ≤3.21 Pa is required. Therefore, an MEMS design with WLVP optimization for the NIR spectral range with minimized static and dynamic mirror deformation of ≤100 nm was developed. For hermetic sealing, glass-frit bonding at elevated process temperatures of 430–440 °C was used to ensure compatibility with a qualified MEMS processes. Finally, a WLVP MEMS with a vacuum pressure of ≤0.15 Pa and Q ≥ 38,600 was realized, resulting in a stroke of 700 µm at 267 Hz for driving at 4 V in parametric resonance. The long-term stability of the 0.2 Pa interior vacuum was successfully tested using a Ne fine-leakage test and resulted in an estimated lifetime of >10 years. This meets the requirements of a compact NIR-FTS.
format Online
Article
Text
id pubmed-7598276
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75982762020-10-31 Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers Sandner, Thilo Gaumont, Eric Graßhoff, Thomas Rieck, Andreas Seifert, Tobias Auböck, Gerald Grahmann, Jan Micromachines (Basel) Article We present a wafer-level vacuum-packaged (WLVP) translatory micro-electro-mechanical system (MEMS) actuator developed for a compact near-infrared-Fourier transform spectrometer (NIR-FTS) with 800–2500 nm spectral bandwidth and signal-nose-ratio (SNR) > 1000 in the smaller bandwidth range (1200–2500 nm) for 1 s measuring time. Although monolithic, highly miniaturized MEMS NIR-FTSs exist today, we follow a classical optical FT instrumentation using a resonant MEMS mirror of 5 mm diameter with precise out-of-plane translatory oscillation for optical path-length modulation. Compared to highly miniaturized MEMS NIR-FTS, the present concept features higher optical throughput and resolution, as well as mechanical robustness and insensitivity to vibration and mechanical shock, compared to conventional FTS mirror drives. The large-stroke MEMS design uses a fully symmetrical four-pantograph suspension, avoiding problems with tilting and parasitic modes. Due to significant gas damping, a permanent vacuum of ≤3.21 Pa is required. Therefore, an MEMS design with WLVP optimization for the NIR spectral range with minimized static and dynamic mirror deformation of ≤100 nm was developed. For hermetic sealing, glass-frit bonding at elevated process temperatures of 430–440 °C was used to ensure compatibility with a qualified MEMS processes. Finally, a WLVP MEMS with a vacuum pressure of ≤0.15 Pa and Q ≥ 38,600 was realized, resulting in a stroke of 700 µm at 267 Hz for driving at 4 V in parametric resonance. The long-term stability of the 0.2 Pa interior vacuum was successfully tested using a Ne fine-leakage test and resulted in an estimated lifetime of >10 years. This meets the requirements of a compact NIR-FTS. MDPI 2020-09-23 /pmc/articles/PMC7598276/ /pubmed/32977467 http://dx.doi.org/10.3390/mi11100883 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sandner, Thilo
Gaumont, Eric
Graßhoff, Thomas
Rieck, Andreas
Seifert, Tobias
Auböck, Gerald
Grahmann, Jan
Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers
title Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers
title_full Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers
title_fullStr Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers
title_full_unstemmed Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers
title_short Wafer-Level Vacuum-Packaged Translatory MEMS Actuator with Large Stroke for NIR-FT Spectrometers
title_sort wafer-level vacuum-packaged translatory mems actuator with large stroke for nir-ft spectrometers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7598276/
https://www.ncbi.nlm.nih.gov/pubmed/32977467
http://dx.doi.org/10.3390/mi11100883
work_keys_str_mv AT sandnerthilo waferlevelvacuumpackagedtranslatorymemsactuatorwithlargestrokefornirftspectrometers
AT gaumonteric waferlevelvacuumpackagedtranslatorymemsactuatorwithlargestrokefornirftspectrometers
AT graßhoffthomas waferlevelvacuumpackagedtranslatorymemsactuatorwithlargestrokefornirftspectrometers
AT rieckandreas waferlevelvacuumpackagedtranslatorymemsactuatorwithlargestrokefornirftspectrometers
AT seiferttobias waferlevelvacuumpackagedtranslatorymemsactuatorwithlargestrokefornirftspectrometers
AT aubockgerald waferlevelvacuumpackagedtranslatorymemsactuatorwithlargestrokefornirftspectrometers
AT grahmannjan waferlevelvacuumpackagedtranslatorymemsactuatorwithlargestrokefornirftspectrometers