Cargando…

Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk

OBJECTIVES: Percutaneous liver biopsy (PLB) poses specific challenges in oncological patients such as bleeding and tumour seeding. This study’s aim was to compare a coaxial (C-PLB) and non-coaxial (NC-PLB) biopsy technique in terms of diagnostic yield, safety and seeding risk of image-guided PLB tec...

Descripción completa

Detalles Bibliográficos
Autores principales: Fotiadis, Nicos, De Paepe, Katja N., Bonne, Lawrence, Khan, Nasir, Riddell, Angela, Turner, Nicholas, Starling, Naureen, Gerlinger, Marco, Rao, Sheela, Chau, Ian, Cunningham, David, Koh, Dow-Mu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7599171/
https://www.ncbi.nlm.nih.gov/pubmed/32666317
http://dx.doi.org/10.1007/s00330-020-07038-7
_version_ 1783602813845110784
author Fotiadis, Nicos
De Paepe, Katja N.
Bonne, Lawrence
Khan, Nasir
Riddell, Angela
Turner, Nicholas
Starling, Naureen
Gerlinger, Marco
Rao, Sheela
Chau, Ian
Cunningham, David
Koh, Dow-Mu
author_facet Fotiadis, Nicos
De Paepe, Katja N.
Bonne, Lawrence
Khan, Nasir
Riddell, Angela
Turner, Nicholas
Starling, Naureen
Gerlinger, Marco
Rao, Sheela
Chau, Ian
Cunningham, David
Koh, Dow-Mu
author_sort Fotiadis, Nicos
collection PubMed
description OBJECTIVES: Percutaneous liver biopsy (PLB) poses specific challenges in oncological patients such as bleeding and tumour seeding. This study’s aim was to compare a coaxial (C-PLB) and non-coaxial (NC-PLB) biopsy technique in terms of diagnostic yield, safety and seeding risk of image-guided PLB techniques in an oncological setting. METHODS: Local research committee approval was obtained for this single-site retrospective study. Patients who underwent a PLB between November 2011 and December 2017 were consecutively included. Medical records were reviewed to determine diagnostic yield and complications. Follow-up imaging was re-reviewed for seeding, defined as visible tumour deposits along the PLB track. Mann-Whitney U and chi-squared tests were performed to investigate differences between biopsy techniques in sample number, complications and seeding rate. RESULTS: In total, 741 patients (62 ± 13 years, 378 women) underwent 932 PLB (C-PLB 72.9% (679/932); NC-PLB 27.1% (253/932)). More tissue cores (p < 0.001) were obtained with C-PLB (median 4 cores; range 1–12) compared with NC-PLB (2 cores; range 1–4) and diagnostic yield was similar for both techniques (C-PLB 92.6% (629/679); NC-PLB 92.5% (234/253); p = 0.940). Complication rate (9.3%; 87/932) using C-PLB (8.2% (56/679)) was lower compared with NC-PLB (12.3% (31/253); p = 0.024). Major complications were uncommon (C-PLB 2.7% (18/679); NC-PLB 2.8% (7/253)); bleeding developed in 1.2% (11/932; C-PLB 1.2% (8/679); NC-PLB 1.2% (3/253)). Seeding was a rare event, occurring significantly less in C-PLB cases (C-PLB 1.3% (7/544); NC-PLB 3.1% (6/197); p = 0.021). CONCLUSIONS: C-PLB allows for high diagnostic tissue yield with a lower complication and seeding rate than a NC-PLB and should be the preferred method in an oncological setting. KEY POINTS: • A coaxial percutaneous liver biopsy achieves a significant higher number of cores and fewer complications than a non-coaxial biopsy technique. • The risk of tumour seeding is very low and is significantly lower using the coaxial biopsy technique. • In this study, a larger number of cores (median = 4) could be safely acquired using the coaxial technique, providing sufficient material for advanced molecular analysis.
format Online
Article
Text
id pubmed-7599171
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-75991712020-11-10 Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk Fotiadis, Nicos De Paepe, Katja N. Bonne, Lawrence Khan, Nasir Riddell, Angela Turner, Nicholas Starling, Naureen Gerlinger, Marco Rao, Sheela Chau, Ian Cunningham, David Koh, Dow-Mu Eur Radiol Hepatobiliary-Pancreas OBJECTIVES: Percutaneous liver biopsy (PLB) poses specific challenges in oncological patients such as bleeding and tumour seeding. This study’s aim was to compare a coaxial (C-PLB) and non-coaxial (NC-PLB) biopsy technique in terms of diagnostic yield, safety and seeding risk of image-guided PLB techniques in an oncological setting. METHODS: Local research committee approval was obtained for this single-site retrospective study. Patients who underwent a PLB between November 2011 and December 2017 were consecutively included. Medical records were reviewed to determine diagnostic yield and complications. Follow-up imaging was re-reviewed for seeding, defined as visible tumour deposits along the PLB track. Mann-Whitney U and chi-squared tests were performed to investigate differences between biopsy techniques in sample number, complications and seeding rate. RESULTS: In total, 741 patients (62 ± 13 years, 378 women) underwent 932 PLB (C-PLB 72.9% (679/932); NC-PLB 27.1% (253/932)). More tissue cores (p < 0.001) were obtained with C-PLB (median 4 cores; range 1–12) compared with NC-PLB (2 cores; range 1–4) and diagnostic yield was similar for both techniques (C-PLB 92.6% (629/679); NC-PLB 92.5% (234/253); p = 0.940). Complication rate (9.3%; 87/932) using C-PLB (8.2% (56/679)) was lower compared with NC-PLB (12.3% (31/253); p = 0.024). Major complications were uncommon (C-PLB 2.7% (18/679); NC-PLB 2.8% (7/253)); bleeding developed in 1.2% (11/932; C-PLB 1.2% (8/679); NC-PLB 1.2% (3/253)). Seeding was a rare event, occurring significantly less in C-PLB cases (C-PLB 1.3% (7/544); NC-PLB 3.1% (6/197); p = 0.021). CONCLUSIONS: C-PLB allows for high diagnostic tissue yield with a lower complication and seeding rate than a NC-PLB and should be the preferred method in an oncological setting. KEY POINTS: • A coaxial percutaneous liver biopsy achieves a significant higher number of cores and fewer complications than a non-coaxial biopsy technique. • The risk of tumour seeding is very low and is significantly lower using the coaxial biopsy technique. • In this study, a larger number of cores (median = 4) could be safely acquired using the coaxial technique, providing sufficient material for advanced molecular analysis. Springer Berlin Heidelberg 2020-07-14 2020 /pmc/articles/PMC7599171/ /pubmed/32666317 http://dx.doi.org/10.1007/s00330-020-07038-7 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Hepatobiliary-Pancreas
Fotiadis, Nicos
De Paepe, Katja N.
Bonne, Lawrence
Khan, Nasir
Riddell, Angela
Turner, Nicholas
Starling, Naureen
Gerlinger, Marco
Rao, Sheela
Chau, Ian
Cunningham, David
Koh, Dow-Mu
Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk
title Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk
title_full Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk
title_fullStr Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk
title_full_unstemmed Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk
title_short Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk
title_sort comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk
topic Hepatobiliary-Pancreas
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7599171/
https://www.ncbi.nlm.nih.gov/pubmed/32666317
http://dx.doi.org/10.1007/s00330-020-07038-7
work_keys_str_mv AT fotiadisnicos comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT depaepekatjan comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT bonnelawrence comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT khannasir comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT riddellangela comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT turnernicholas comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT starlingnaureen comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT gerlingermarco comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT raosheela comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT chauian comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT cunninghamdavid comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk
AT kohdowmu comparisonofacoaxialversusnoncoaxialliverbiopsytechniqueinanoncologicalsettingdiagnosticyieldcomplicationsandseedingrisk