Cargando…

Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial

Objectives: Peripheral intravenous catheters (PIVC) are the most frequently used invasive devices in medicine. PIVC failure before treatment completion is a significant concern and occurs in 33–69% of patients. Partial dislodgement and accidental removal are some of the reasons for PIVC failure. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmutz, Axel, Menz, Lea, Schumann, Stefan, Heinrich, Sebastian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7601033/
https://www.ncbi.nlm.nih.gov/pubmed/33019691
http://dx.doi.org/10.3390/jcm9103192
_version_ 1783603302412320768
author Schmutz, Axel
Menz, Lea
Schumann, Stefan
Heinrich, Sebastian
author_facet Schmutz, Axel
Menz, Lea
Schumann, Stefan
Heinrich, Sebastian
author_sort Schmutz, Axel
collection PubMed
description Objectives: Peripheral intravenous catheters (PIVC) are the most frequently used invasive devices in medicine. PIVC failure before treatment completion is a significant concern and occurs in 33–69% of patients. Partial dislodgement and accidental removal are some of the reasons for PIVC failure. The most effective dressing and securement method for preventing accidental removal remains unclear. It was the aim of this study to compare the force required to dislodge a PIVC with four commonly used dressing and securement methods. Additionally, costs were calculated. Methods: Truncated 18-gauge i.v. cannulas were attached onto the forearm of 209 volunteers using four different dressings and securements (sterile absorbent wound dressing covered by two different types of elastic polyester fleece, bordered and non-bordered polyurethane). The force during continuously stronger pulling until dislodgement was recorded. Results: The highest resistance against dislodgement forces could be observed with a sterile absorbent wound dressing covered by two incised elastic polyester fleece dressings. Commercially-manufactured bordered and non-bordered polyurethan film dressings were 20% to 75% more expensive than sterile absorbent wound dressings covered by elastic polyester fleece dressing. Conclusions: Elastic polyester fleece secured a PIVC against accidental removal by external force best, compared to commercially-manufactured bordered and non-bordered polyurethane film dressing.
format Online
Article
Text
id pubmed-7601033
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76010332020-11-01 Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial Schmutz, Axel Menz, Lea Schumann, Stefan Heinrich, Sebastian J Clin Med Article Objectives: Peripheral intravenous catheters (PIVC) are the most frequently used invasive devices in medicine. PIVC failure before treatment completion is a significant concern and occurs in 33–69% of patients. Partial dislodgement and accidental removal are some of the reasons for PIVC failure. The most effective dressing and securement method for preventing accidental removal remains unclear. It was the aim of this study to compare the force required to dislodge a PIVC with four commonly used dressing and securement methods. Additionally, costs were calculated. Methods: Truncated 18-gauge i.v. cannulas were attached onto the forearm of 209 volunteers using four different dressings and securements (sterile absorbent wound dressing covered by two different types of elastic polyester fleece, bordered and non-bordered polyurethane). The force during continuously stronger pulling until dislodgement was recorded. Results: The highest resistance against dislodgement forces could be observed with a sterile absorbent wound dressing covered by two incised elastic polyester fleece dressings. Commercially-manufactured bordered and non-bordered polyurethan film dressings were 20% to 75% more expensive than sterile absorbent wound dressings covered by elastic polyester fleece dressing. Conclusions: Elastic polyester fleece secured a PIVC against accidental removal by external force best, compared to commercially-manufactured bordered and non-bordered polyurethane film dressing. MDPI 2020-10-01 /pmc/articles/PMC7601033/ /pubmed/33019691 http://dx.doi.org/10.3390/jcm9103192 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Schmutz, Axel
Menz, Lea
Schumann, Stefan
Heinrich, Sebastian
Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial
title Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial
title_full Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial
title_fullStr Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial
title_full_unstemmed Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial
title_short Dislodgement Forces and Cost Effectiveness of Dressings and Securement for Peripheral Intravenous Catheters: A Randomized Controlled Trial
title_sort dislodgement forces and cost effectiveness of dressings and securement for peripheral intravenous catheters: a randomized controlled trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7601033/
https://www.ncbi.nlm.nih.gov/pubmed/33019691
http://dx.doi.org/10.3390/jcm9103192
work_keys_str_mv AT schmutzaxel dislodgementforcesandcosteffectivenessofdressingsandsecurementforperipheralintravenouscathetersarandomizedcontrolledtrial
AT menzlea dislodgementforcesandcosteffectivenessofdressingsandsecurementforperipheralintravenouscathetersarandomizedcontrolledtrial
AT schumannstefan dislodgementforcesandcosteffectivenessofdressingsandsecurementforperipheralintravenouscathetersarandomizedcontrolledtrial
AT heinrichsebastian dislodgementforcesandcosteffectivenessofdressingsandsecurementforperipheralintravenouscathetersarandomizedcontrolledtrial