Cargando…
Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry
Purpose: The low-profile visualized intraluminal support junior (LVIS Jr.) is a new generation low-profile braided stent. Our aim was to evaluate the safety and efficacy of the LVIS Jr. in the stent-assisted coiling of unruptured middle cerebral artery (MCA) aneurysms. This was a multicenter retrosp...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7601776/ https://www.ncbi.nlm.nih.gov/pubmed/33007864 http://dx.doi.org/10.3390/jcm9103168 |
_version_ | 1783603512533319680 |
---|---|
author | Poncyljusz, Wojciech Zwarzany, Łukasz Limanówka, Bartosz Zbroszczyk, Miłosz Banach, Mariusz Bereza, Sławomir Sagan, Leszek |
author_facet | Poncyljusz, Wojciech Zwarzany, Łukasz Limanówka, Bartosz Zbroszczyk, Miłosz Banach, Mariusz Bereza, Sławomir Sagan, Leszek |
author_sort | Poncyljusz, Wojciech |
collection | PubMed |
description | Purpose: The low-profile visualized intraluminal support junior (LVIS Jr.) is a new generation low-profile braided stent. Our aim was to evaluate the safety and efficacy of the LVIS Jr. in the stent-assisted coiling of unruptured middle cerebral artery (MCA) aneurysms. This was a multicenter retrospective study. Patient demographics, aneurysm characteristics, procedural details, complications, and the results of clinical and imaging follow-up were analyzed. Four centers participated in the study. A total of 162 consecutive patients with 162 unruptured MCA aneurysms were included for the analysis. The mean aneurysm size was 7.6 mm (range 2 to 37 mm) and 97.5% were wide-necked. Immediate postprocedural angiograms showed Raymond-Roy class 1 in 118 (72.8%), class 2 in 23 (14.2%), and class 3 in 21 patients (13%). Periprocedural complications occurred in 14 patients (8.6%). There were no procedure-related deaths. Follow-up imaging at 12–18 months post-procedure showed Raymond–Roy class 1 in 132 (81.5%), class 2 in 17 (10.5%), and class 3 in 13 patients (8%). There were 3 cases of in-stent stenosis (1.9%). All 162 patients had good clinical outcome (mRS score 0–2) at 90 days post-procedure. Stent-assisted coiling of unruptured MCA aneurysms with the LVIS Jr. stent is safe and effective, with high immediate and long-term total occlusion rates. |
format | Online Article Text |
id | pubmed-7601776 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76017762020-11-01 Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry Poncyljusz, Wojciech Zwarzany, Łukasz Limanówka, Bartosz Zbroszczyk, Miłosz Banach, Mariusz Bereza, Sławomir Sagan, Leszek J Clin Med Article Purpose: The low-profile visualized intraluminal support junior (LVIS Jr.) is a new generation low-profile braided stent. Our aim was to evaluate the safety and efficacy of the LVIS Jr. in the stent-assisted coiling of unruptured middle cerebral artery (MCA) aneurysms. This was a multicenter retrospective study. Patient demographics, aneurysm characteristics, procedural details, complications, and the results of clinical and imaging follow-up were analyzed. Four centers participated in the study. A total of 162 consecutive patients with 162 unruptured MCA aneurysms were included for the analysis. The mean aneurysm size was 7.6 mm (range 2 to 37 mm) and 97.5% were wide-necked. Immediate postprocedural angiograms showed Raymond-Roy class 1 in 118 (72.8%), class 2 in 23 (14.2%), and class 3 in 21 patients (13%). Periprocedural complications occurred in 14 patients (8.6%). There were no procedure-related deaths. Follow-up imaging at 12–18 months post-procedure showed Raymond–Roy class 1 in 132 (81.5%), class 2 in 17 (10.5%), and class 3 in 13 patients (8%). There were 3 cases of in-stent stenosis (1.9%). All 162 patients had good clinical outcome (mRS score 0–2) at 90 days post-procedure. Stent-assisted coiling of unruptured MCA aneurysms with the LVIS Jr. stent is safe and effective, with high immediate and long-term total occlusion rates. MDPI 2020-09-30 /pmc/articles/PMC7601776/ /pubmed/33007864 http://dx.doi.org/10.3390/jcm9103168 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Poncyljusz, Wojciech Zwarzany, Łukasz Limanówka, Bartosz Zbroszczyk, Miłosz Banach, Mariusz Bereza, Sławomir Sagan, Leszek Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry |
title | Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry |
title_full | Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry |
title_fullStr | Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry |
title_full_unstemmed | Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry |
title_short | Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry |
title_sort | stent-assisted coiling of unruptured mca aneurysms using the lvis jr. device: a multicenter registry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7601776/ https://www.ncbi.nlm.nih.gov/pubmed/33007864 http://dx.doi.org/10.3390/jcm9103168 |
work_keys_str_mv | AT poncyljuszwojciech stentassistedcoilingofunrupturedmcaaneurysmsusingthelvisjrdeviceamulticenterregistry AT zwarzanyłukasz stentassistedcoilingofunrupturedmcaaneurysmsusingthelvisjrdeviceamulticenterregistry AT limanowkabartosz stentassistedcoilingofunrupturedmcaaneurysmsusingthelvisjrdeviceamulticenterregistry AT zbroszczykmiłosz stentassistedcoilingofunrupturedmcaaneurysmsusingthelvisjrdeviceamulticenterregistry AT banachmariusz stentassistedcoilingofunrupturedmcaaneurysmsusingthelvisjrdeviceamulticenterregistry AT berezasławomir stentassistedcoilingofunrupturedmcaaneurysmsusingthelvisjrdeviceamulticenterregistry AT saganleszek stentassistedcoilingofunrupturedmcaaneurysmsusingthelvisjrdeviceamulticenterregistry |