Cargando…

The detection of lung cancer using massive artificial neural network based on soft tissue technique

BACKGROUND: A proposed computer aided detection (CAD) scheme faces major issues during subtle nodule recognition. However, radiologists have not noticed subtle nodules in beginning stage of lung cancer while a proposed CAD scheme recognizes non subtle nodules using x-ray images. METHOD: Such an issu...

Descripción completa

Detalles Bibliográficos
Autores principales: Rajagopalan, Kishore, Babu, Suresh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7602294/
https://www.ncbi.nlm.nih.gov/pubmed/33129343
http://dx.doi.org/10.1186/s12911-020-01220-z
_version_ 1783603645416210432
author Rajagopalan, Kishore
Babu, Suresh
author_facet Rajagopalan, Kishore
Babu, Suresh
author_sort Rajagopalan, Kishore
collection PubMed
description BACKGROUND: A proposed computer aided detection (CAD) scheme faces major issues during subtle nodule recognition. However, radiologists have not noticed subtle nodules in beginning stage of lung cancer while a proposed CAD scheme recognizes non subtle nodules using x-ray images. METHOD: Such an issue has been resolved by creating MANN (Massive Artificial Neural Network) based soft tissue technique from the lung segmented x-ray image. A soft tissue image recognizes nodule candidate for feature extortion and classification. X-ray images are downloaded using Japanese society of radiological technology (JSRT) image set. This image set includes 233 images (140 nodule x-ray images and 93 normal x-ray images). A mean size for a nodule is 17.8 mm and it is validated with computed tomography (CT) image. Thirty percent (42/140) abnormal represents subtle nodules and it is split into five stages (tremendously subtle, very subtle, subtle, observable, relatively observable) by radiologists. RESULT: A proposed CAD scheme without soft tissue technique attained 66.42% (93/140) sensitivity and 66.76% accuracy having 2.5 false positives per image. Utilizing soft tissue technique, many nodules superimposed by ribs as well as clavicles have identified (sensitivity is 72.85% (102/140) and accuracy is 72.96% at one false positive rate). CONCLUSION: In particular, a proposed CAD system determine sensitivity and accuracy in support of subtle nodules (sensitivity is 14/42 = 33.33% and accuracy is 33.66%) is statistically higher than CAD (sensitivity is 13/42 = 30.95% and accuracy is 30.97%) scheme without soft tissue technique. A proposed CAD scheme attained tremendously minimum false positive rate and it is a promising technique in support of cancerous recognition due to improved sensitivity and specificity.
format Online
Article
Text
id pubmed-7602294
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-76022942020-11-02 The detection of lung cancer using massive artificial neural network based on soft tissue technique Rajagopalan, Kishore Babu, Suresh BMC Med Inform Decis Mak Technical Advance BACKGROUND: A proposed computer aided detection (CAD) scheme faces major issues during subtle nodule recognition. However, radiologists have not noticed subtle nodules in beginning stage of lung cancer while a proposed CAD scheme recognizes non subtle nodules using x-ray images. METHOD: Such an issue has been resolved by creating MANN (Massive Artificial Neural Network) based soft tissue technique from the lung segmented x-ray image. A soft tissue image recognizes nodule candidate for feature extortion and classification. X-ray images are downloaded using Japanese society of radiological technology (JSRT) image set. This image set includes 233 images (140 nodule x-ray images and 93 normal x-ray images). A mean size for a nodule is 17.8 mm and it is validated with computed tomography (CT) image. Thirty percent (42/140) abnormal represents subtle nodules and it is split into five stages (tremendously subtle, very subtle, subtle, observable, relatively observable) by radiologists. RESULT: A proposed CAD scheme without soft tissue technique attained 66.42% (93/140) sensitivity and 66.76% accuracy having 2.5 false positives per image. Utilizing soft tissue technique, many nodules superimposed by ribs as well as clavicles have identified (sensitivity is 72.85% (102/140) and accuracy is 72.96% at one false positive rate). CONCLUSION: In particular, a proposed CAD system determine sensitivity and accuracy in support of subtle nodules (sensitivity is 14/42 = 33.33% and accuracy is 33.66%) is statistically higher than CAD (sensitivity is 13/42 = 30.95% and accuracy is 30.97%) scheme without soft tissue technique. A proposed CAD scheme attained tremendously minimum false positive rate and it is a promising technique in support of cancerous recognition due to improved sensitivity and specificity. BioMed Central 2020-10-31 /pmc/articles/PMC7602294/ /pubmed/33129343 http://dx.doi.org/10.1186/s12911-020-01220-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Technical Advance
Rajagopalan, Kishore
Babu, Suresh
The detection of lung cancer using massive artificial neural network based on soft tissue technique
title The detection of lung cancer using massive artificial neural network based on soft tissue technique
title_full The detection of lung cancer using massive artificial neural network based on soft tissue technique
title_fullStr The detection of lung cancer using massive artificial neural network based on soft tissue technique
title_full_unstemmed The detection of lung cancer using massive artificial neural network based on soft tissue technique
title_short The detection of lung cancer using massive artificial neural network based on soft tissue technique
title_sort detection of lung cancer using massive artificial neural network based on soft tissue technique
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7602294/
https://www.ncbi.nlm.nih.gov/pubmed/33129343
http://dx.doi.org/10.1186/s12911-020-01220-z
work_keys_str_mv AT rajagopalankishore thedetectionoflungcancerusingmassiveartificialneuralnetworkbasedonsofttissuetechnique
AT babusuresh thedetectionoflungcancerusingmassiveartificialneuralnetworkbasedonsofttissuetechnique
AT rajagopalankishore detectionoflungcancerusingmassiveartificialneuralnetworkbasedonsofttissuetechnique
AT babusuresh detectionoflungcancerusingmassiveartificialneuralnetworkbasedonsofttissuetechnique