Cargando…

Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe

Background: High frequency oscillations (HFOs) have attracted great interest among neuroscientists and epileptologists in recent years. Not only has their occurrence been linked to epileptogenesis, but also to physiologic processes, such as memory consolidation. There are at least two big challenges...

Descripción completa

Detalles Bibliográficos
Autores principales: Thomschewski, Aljoscha, Gerner, Nathalie, Langthaler, Patrick B., Trinka, Eugen, Bathke, Arne C., Fell, Jürgen, Höller, Yvonne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7604344/
https://www.ncbi.nlm.nih.gov/pubmed/33192999
http://dx.doi.org/10.3389/fneur.2020.563577
_version_ 1783604126481907712
author Thomschewski, Aljoscha
Gerner, Nathalie
Langthaler, Patrick B.
Trinka, Eugen
Bathke, Arne C.
Fell, Jürgen
Höller, Yvonne
author_facet Thomschewski, Aljoscha
Gerner, Nathalie
Langthaler, Patrick B.
Trinka, Eugen
Bathke, Arne C.
Fell, Jürgen
Höller, Yvonne
author_sort Thomschewski, Aljoscha
collection PubMed
description Background: High frequency oscillations (HFOs) have attracted great interest among neuroscientists and epileptologists in recent years. Not only has their occurrence been linked to epileptogenesis, but also to physiologic processes, such as memory consolidation. There are at least two big challenges for HFO research. First, detection, when performed manually, is time consuming and prone to rater biases, but when performed automatically, it is biased by artifacts mimicking HFOs. Second, distinguishing physiologic from pathologic HFOs in patients with epilepsy is problematic. Here we automatically and manually detected HFOs in intracranial EEGs (iEEG) of patients with epilepsy, recorded during a visual memory task in order to assess the feasibility of the different detection approaches to identify task-related ripples, supporting the physiologic nature of HFOs in the temporal lobe. Methods: Ten patients with unclear seizure origin and bilaterally implanted macroelectrodes took part in a visual memory consolidation task. In addition to iEEG, scalp EEG, electrooculography (EOG), and facial electromyography (EMG) were recorded. iEEG channels contralateral to the suspected epileptogenic zone were inspected visually for HFOs. Furthermore, HFOs were marked automatically using an RMS detector and a Stockwell classifier. We compared the two detection approaches and assessed a possible link between task performance and HFO occurrence during encoding and retrieval trials. Results: HFO occurrence rates were significantly lower when events were marked manually. The automatic detection algorithm was greatly biased by filter-artifacts. Surprisingly, EOG artifacts as seen on scalp electrodes appeared to be linked to many HFOs in the iEEG. Occurrence rates could not be associated to memory performance, and we were not able to detect strictly defined “clear” ripples. Conclusion: Filtered graphoelements in the EEG are known to mimic HFOs and thus constitute a problem. So far, in invasive EEG recordings mostly technical artifacts and filtered epileptiform discharges have been considered as sources for these “false” HFOs. The data at hand suggests that even ocular artifacts might bias automatic detection in invasive recordings. Strict guidelines and standards for HFO detection are necessary in order to identify artifact-derived HFOs, especially in conditions when cognitive tasks might produce a high amount of artifacts.
format Online
Article
Text
id pubmed-7604344
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-76043442020-11-13 Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe Thomschewski, Aljoscha Gerner, Nathalie Langthaler, Patrick B. Trinka, Eugen Bathke, Arne C. Fell, Jürgen Höller, Yvonne Front Neurol Neurology Background: High frequency oscillations (HFOs) have attracted great interest among neuroscientists and epileptologists in recent years. Not only has their occurrence been linked to epileptogenesis, but also to physiologic processes, such as memory consolidation. There are at least two big challenges for HFO research. First, detection, when performed manually, is time consuming and prone to rater biases, but when performed automatically, it is biased by artifacts mimicking HFOs. Second, distinguishing physiologic from pathologic HFOs in patients with epilepsy is problematic. Here we automatically and manually detected HFOs in intracranial EEGs (iEEG) of patients with epilepsy, recorded during a visual memory task in order to assess the feasibility of the different detection approaches to identify task-related ripples, supporting the physiologic nature of HFOs in the temporal lobe. Methods: Ten patients with unclear seizure origin and bilaterally implanted macroelectrodes took part in a visual memory consolidation task. In addition to iEEG, scalp EEG, electrooculography (EOG), and facial electromyography (EMG) were recorded. iEEG channels contralateral to the suspected epileptogenic zone were inspected visually for HFOs. Furthermore, HFOs were marked automatically using an RMS detector and a Stockwell classifier. We compared the two detection approaches and assessed a possible link between task performance and HFO occurrence during encoding and retrieval trials. Results: HFO occurrence rates were significantly lower when events were marked manually. The automatic detection algorithm was greatly biased by filter-artifacts. Surprisingly, EOG artifacts as seen on scalp electrodes appeared to be linked to many HFOs in the iEEG. Occurrence rates could not be associated to memory performance, and we were not able to detect strictly defined “clear” ripples. Conclusion: Filtered graphoelements in the EEG are known to mimic HFOs and thus constitute a problem. So far, in invasive EEG recordings mostly technical artifacts and filtered epileptiform discharges have been considered as sources for these “false” HFOs. The data at hand suggests that even ocular artifacts might bias automatic detection in invasive recordings. Strict guidelines and standards for HFO detection are necessary in order to identify artifact-derived HFOs, especially in conditions when cognitive tasks might produce a high amount of artifacts. Frontiers Media S.A. 2020-10-19 /pmc/articles/PMC7604344/ /pubmed/33192999 http://dx.doi.org/10.3389/fneur.2020.563577 Text en Copyright © 2020 Thomschewski, Gerner, Langthaler, Trinka, Bathke, Fell and Höller. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Thomschewski, Aljoscha
Gerner, Nathalie
Langthaler, Patrick B.
Trinka, Eugen
Bathke, Arne C.
Fell, Jürgen
Höller, Yvonne
Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe
title Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe
title_full Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe
title_fullStr Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe
title_full_unstemmed Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe
title_short Automatic vs. Manual Detection of High Frequency Oscillations in Intracranial Recordings From the Human Temporal Lobe
title_sort automatic vs. manual detection of high frequency oscillations in intracranial recordings from the human temporal lobe
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7604344/
https://www.ncbi.nlm.nih.gov/pubmed/33192999
http://dx.doi.org/10.3389/fneur.2020.563577
work_keys_str_mv AT thomschewskialjoscha automaticvsmanualdetectionofhighfrequencyoscillationsinintracranialrecordingsfromthehumantemporallobe
AT gernernathalie automaticvsmanualdetectionofhighfrequencyoscillationsinintracranialrecordingsfromthehumantemporallobe
AT langthalerpatrickb automaticvsmanualdetectionofhighfrequencyoscillationsinintracranialrecordingsfromthehumantemporallobe
AT trinkaeugen automaticvsmanualdetectionofhighfrequencyoscillationsinintracranialrecordingsfromthehumantemporallobe
AT bathkearnec automaticvsmanualdetectionofhighfrequencyoscillationsinintracranialrecordingsfromthehumantemporallobe
AT felljurgen automaticvsmanualdetectionofhighfrequencyoscillationsinintracranialrecordingsfromthehumantemporallobe
AT holleryvonne automaticvsmanualdetectionofhighfrequencyoscillationsinintracranialrecordingsfromthehumantemporallobe