Cargando…

Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria

There is a scarcity of data on lung ultrasound (LUS) in SARS-CoV-2 pneumonia. As with many other pulmonary conditions, ultrasound may be a better diagnostic tool than routine chest radiography. In an era where computed tomography scanning is deferred because of the potential for cross-contamination,...

Descripción completa

Detalles Bibliográficos
Autores principales: Jalil, Bilal A., Khan, Ahsan, Kugasia, Irfanali R., Ijaz, Mohsin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605644/
https://www.ncbi.nlm.nih.gov/pubmed/33446945
http://dx.doi.org/10.1080/08998280.2020.1834658
_version_ 1783604345381584896
author Jalil, Bilal A.
Khan, Ahsan
Kugasia, Irfanali R.
Ijaz, Mohsin
author_facet Jalil, Bilal A.
Khan, Ahsan
Kugasia, Irfanali R.
Ijaz, Mohsin
author_sort Jalil, Bilal A.
collection PubMed
description There is a scarcity of data on lung ultrasound (LUS) in SARS-CoV-2 pneumonia. As with many other pulmonary conditions, ultrasound may be a better diagnostic tool than routine chest radiography. In an era where computed tomography scanning is deferred because of the potential for cross-contamination, we evaluated the ability of LUS to detect a pattern of lung injury in SARS-CoV-2 pneumonia. A limited anterolateral LUS was performed to limit time spent in isolation rooms by ultrasound operators. We chose to use a hand-held ultrasound device due to portability and superior confidence in infection control. Both linear and phased array probes were used to obtain images of the pleura and lung. Of 69 patients who had lung ultrasound images saved and were included in the analysis, 36 were positive for SARS-CoV-2. Multifocal confluent B-lines, pleural irregularities, and the absence of moderate or large pleural effusions were the predominant pattern observed in most (86%) of SARS-CoV-2–positive patients. We evaluated the accuracy of the above criteria (LUS-CoV) and report a high sensitivity (91%) and specificity (86%) for SARS-CoV-2 pneumonia. In conclusion, a characteristic sonographic pattern of multifocal confluent B-lines with irregular pleural markings was seen on LUS in patients with SARS-CoV-2 pneumonia.
format Online
Article
Text
id pubmed-7605644
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-76056442020-11-02 Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria Jalil, Bilal A. Khan, Ahsan Kugasia, Irfanali R. Ijaz, Mohsin Proc (Bayl Univ Med Cent) Original Research There is a scarcity of data on lung ultrasound (LUS) in SARS-CoV-2 pneumonia. As with many other pulmonary conditions, ultrasound may be a better diagnostic tool than routine chest radiography. In an era where computed tomography scanning is deferred because of the potential for cross-contamination, we evaluated the ability of LUS to detect a pattern of lung injury in SARS-CoV-2 pneumonia. A limited anterolateral LUS was performed to limit time spent in isolation rooms by ultrasound operators. We chose to use a hand-held ultrasound device due to portability and superior confidence in infection control. Both linear and phased array probes were used to obtain images of the pleura and lung. Of 69 patients who had lung ultrasound images saved and were included in the analysis, 36 were positive for SARS-CoV-2. Multifocal confluent B-lines, pleural irregularities, and the absence of moderate or large pleural effusions were the predominant pattern observed in most (86%) of SARS-CoV-2–positive patients. We evaluated the accuracy of the above criteria (LUS-CoV) and report a high sensitivity (91%) and specificity (86%) for SARS-CoV-2 pneumonia. In conclusion, a characteristic sonographic pattern of multifocal confluent B-lines with irregular pleural markings was seen on LUS in patients with SARS-CoV-2 pneumonia. Taylor & Francis 2020-10-26 /pmc/articles/PMC7605644/ /pubmed/33446945 http://dx.doi.org/10.1080/08998280.2020.1834658 Text en Copyright © 2020 Baylor University Medical Center
spellingShingle Original Research
Jalil, Bilal A.
Khan, Ahsan
Kugasia, Irfanali R.
Ijaz, Mohsin
Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria
title Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria
title_full Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria
title_fullStr Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria
title_full_unstemmed Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria
title_short Lung ultrasound in early SARS-CoV-2 pneumonia and the LUS-CoV criteria
title_sort lung ultrasound in early sars-cov-2 pneumonia and the lus-cov criteria
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605644/
https://www.ncbi.nlm.nih.gov/pubmed/33446945
http://dx.doi.org/10.1080/08998280.2020.1834658
work_keys_str_mv AT jalilbilala lungultrasoundinearlysarscov2pneumoniaandtheluscovcriteria
AT khanahsan lungultrasoundinearlysarscov2pneumoniaandtheluscovcriteria
AT kugasiairfanalir lungultrasoundinearlysarscov2pneumoniaandtheluscovcriteria
AT ijazmohsin lungultrasoundinearlysarscov2pneumoniaandtheluscovcriteria