Cargando…

Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women

Hip microinstability is a recognized cause of hip pain in young patients. Intra-operative evaluation is used to confirm the diagnosis, but limited data exist associating magnetic resonance arthrography (MRA) findings with hip microinstability. To determine if a difference exists in the thickness of...

Descripción completa

Detalles Bibliográficos
Autores principales: Packer, Jonathan D, Foster, Michael J, Riley, Geoffrey M, Stewart, Russell, Shibata, Kotaro R, Richardson, Michael L, Boutin, Robert D, Safran, Marc R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605766/
https://www.ncbi.nlm.nih.gov/pubmed/33163215
http://dx.doi.org/10.1093/jhps/hnaa018
_version_ 1783604374550872064
author Packer, Jonathan D
Foster, Michael J
Riley, Geoffrey M
Stewart, Russell
Shibata, Kotaro R
Richardson, Michael L
Boutin, Robert D
Safran, Marc R
author_facet Packer, Jonathan D
Foster, Michael J
Riley, Geoffrey M
Stewart, Russell
Shibata, Kotaro R
Richardson, Michael L
Boutin, Robert D
Safran, Marc R
author_sort Packer, Jonathan D
collection PubMed
description Hip microinstability is a recognized cause of hip pain in young patients. Intra-operative evaluation is used to confirm the diagnosis, but limited data exist associating magnetic resonance arthrography (MRA) findings with hip microinstability. To determine if a difference exists in the thickness of the anterior joint capsule and/or the width of the anterior joint recess on MRA in hip arthroscopy patients with and without an intra-operative diagnosis of hip laxity. Sixty-two hip arthroscopy patients were included in the study. Two musculoskeletal radiologists blinded to surgical results reviewed the MRAs for two previously described findings: (i) anterior joint capsule thinning; (ii) widening of the anterior joint recess distal to the zona orbicularis. Operative reports were reviewed for the diagnosis of joint laxity. In all patients with and without intra-operative laxity, there were no significant differences with either MRA measurement. However, twenty-six of 27 patients with intra-operative laxity were women compared with 11 of 35 patients without laxity (P < 0.001). In subgroup analysis of women, the intra-operative laxity group had a higher rate of capsular thinning compared with the non-laxity group (85% versus 45%; P = 0.01). A 82% of women with capsular thinning also had intra-operative laxity, compared with 40% without capsular thinning (P = 0.01). There were no differences regarding the width of the anterior joint recess. In this study, there was an association between capsular thinning and intra-operative laxity in female patients. Measuring anterior capsule thickness on a pre-operative MRA may be useful for the diagnosis of hip microinstability.
format Online
Article
Text
id pubmed-7605766
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-76057662020-11-06 Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women Packer, Jonathan D Foster, Michael J Riley, Geoffrey M Stewart, Russell Shibata, Kotaro R Richardson, Michael L Boutin, Robert D Safran, Marc R J Hip Preserv Surg Research Articles Hip microinstability is a recognized cause of hip pain in young patients. Intra-operative evaluation is used to confirm the diagnosis, but limited data exist associating magnetic resonance arthrography (MRA) findings with hip microinstability. To determine if a difference exists in the thickness of the anterior joint capsule and/or the width of the anterior joint recess on MRA in hip arthroscopy patients with and without an intra-operative diagnosis of hip laxity. Sixty-two hip arthroscopy patients were included in the study. Two musculoskeletal radiologists blinded to surgical results reviewed the MRAs for two previously described findings: (i) anterior joint capsule thinning; (ii) widening of the anterior joint recess distal to the zona orbicularis. Operative reports were reviewed for the diagnosis of joint laxity. In all patients with and without intra-operative laxity, there were no significant differences with either MRA measurement. However, twenty-six of 27 patients with intra-operative laxity were women compared with 11 of 35 patients without laxity (P < 0.001). In subgroup analysis of women, the intra-operative laxity group had a higher rate of capsular thinning compared with the non-laxity group (85% versus 45%; P = 0.01). A 82% of women with capsular thinning also had intra-operative laxity, compared with 40% without capsular thinning (P = 0.01). There were no differences regarding the width of the anterior joint recess. In this study, there was an association between capsular thinning and intra-operative laxity in female patients. Measuring anterior capsule thickness on a pre-operative MRA may be useful for the diagnosis of hip microinstability. Oxford University Press 2020-08-10 /pmc/articles/PMC7605766/ /pubmed/33163215 http://dx.doi.org/10.1093/jhps/hnaa018 Text en © The Author(s) 2020. Published by Oxford University Press. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Research Articles
Packer, Jonathan D
Foster, Michael J
Riley, Geoffrey M
Stewart, Russell
Shibata, Kotaro R
Richardson, Michael L
Boutin, Robert D
Safran, Marc R
Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women
title Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women
title_full Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women
title_fullStr Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women
title_full_unstemmed Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women
title_short Capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women
title_sort capsular thinning on magnetic resonance arthrography is associated with intra-operative hip joint laxity in women
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605766/
https://www.ncbi.nlm.nih.gov/pubmed/33163215
http://dx.doi.org/10.1093/jhps/hnaa018
work_keys_str_mv AT packerjonathand capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen
AT fostermichaelj capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen
AT rileygeoffreym capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen
AT stewartrussell capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen
AT shibatakotaror capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen
AT richardsonmichaell capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen
AT boutinrobertd capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen
AT safranmarcr capsularthinningonmagneticresonancearthrographyisassociatedwithintraoperativehipjointlaxityinwomen