Cargando…
Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19
Videolaryngoscopy screening is essential to help assessing human larynx. The use of 70° optical fiber in association with image recording by analog or digital cameras is one of the methods adopted to perform this examination. Endoscopic exams can contaminate the equipment with several microorganisms...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Voice Foundation. Published by Elsevier Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605857/ https://www.ncbi.nlm.nih.gov/pubmed/33168360 http://dx.doi.org/10.1016/j.jvoice.2020.10.014 |
_version_ | 1783604394973986816 |
---|---|
author | Nagata Cavalheiro, Mariana Fonseca, Vinicius Ribas Zeigelboim, Bianca Simone Costa, Diego F. de Lima, Lucas Viomar Bozzo, Marlon Kleber Tonochi, Rita de Cássia Hartmann, Bruno Ceron |
author_facet | Nagata Cavalheiro, Mariana Fonseca, Vinicius Ribas Zeigelboim, Bianca Simone Costa, Diego F. de Lima, Lucas Viomar Bozzo, Marlon Kleber Tonochi, Rita de Cássia Hartmann, Bruno Ceron |
author_sort | Nagata Cavalheiro, Mariana |
collection | PubMed |
description | Videolaryngoscopy screening is essential to help assessing human larynx. The use of 70° optical fiber in association with image recording by analog or digital cameras is one of the methods adopted to perform this examination. Endoscopic exams can contaminate the equipment with several microorganisms. The pandemic caused by the new coronavirus reinforces the importance of developing efficient barrier methods to be adopted in videolaryngoscopy procedures. Although dental intraoral camera covers are a barrier method authorized by Brazilian health organs, it has not yet been used in videolaryngoscopy examinations. The aim of the current longitudinal, individualized, single-blind, prospective, self-controlled, and accurate study is to evaluate the quality of images generated through, and confidence level of, diagnosis based on videolaryngoscopy performed with intraoral dental camera equipped with disposable protection cap and connected to 70° rigid laryngoscope in vocally healthy individuals. Videolaryngoscopy examinations based on 70° rigid optics were performed in 13 euphonic and asymptomatic volunteers at an otorhinolaryngology specialist clinic; only 1 patient was excluded from the study. Images were taken with, and without, disposable intraoral dental camera protection cap; high-grade disinfection protocol was applied between examinations. Recorded videos were randomly distributed in a single-blind manner in order to be evaluated by four otorhinolaryngologists, who answered a questionnaire comprising three questions. Statistical analysis was used to compare groups – which were defined by the use, or not, of protection cap – based on Wilcoxon nonparametric test. Statistical significance was set at 5% with 95% confidence interval. There was no statistically significant difference in image quality between examinations performed with, and without, protection cap (P= 0.646) or in the diagnosis confidence level of examinations performed with, or without, the barrier method. The use of disposable protection cap on intraoral dental camera did not significantly change the quality of images taken through videolaryngoscopy performed with 70° rigid optics in vocally healthy patients. |
format | Online Article Text |
id | pubmed-7605857 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Voice Foundation. Published by Elsevier Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-76058572020-11-03 Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19 Nagata Cavalheiro, Mariana Fonseca, Vinicius Ribas Zeigelboim, Bianca Simone Costa, Diego F. de Lima, Lucas Viomar Bozzo, Marlon Kleber Tonochi, Rita de Cássia Hartmann, Bruno Ceron J Voice Article Videolaryngoscopy screening is essential to help assessing human larynx. The use of 70° optical fiber in association with image recording by analog or digital cameras is one of the methods adopted to perform this examination. Endoscopic exams can contaminate the equipment with several microorganisms. The pandemic caused by the new coronavirus reinforces the importance of developing efficient barrier methods to be adopted in videolaryngoscopy procedures. Although dental intraoral camera covers are a barrier method authorized by Brazilian health organs, it has not yet been used in videolaryngoscopy examinations. The aim of the current longitudinal, individualized, single-blind, prospective, self-controlled, and accurate study is to evaluate the quality of images generated through, and confidence level of, diagnosis based on videolaryngoscopy performed with intraoral dental camera equipped with disposable protection cap and connected to 70° rigid laryngoscope in vocally healthy individuals. Videolaryngoscopy examinations based on 70° rigid optics were performed in 13 euphonic and asymptomatic volunteers at an otorhinolaryngology specialist clinic; only 1 patient was excluded from the study. Images were taken with, and without, disposable intraoral dental camera protection cap; high-grade disinfection protocol was applied between examinations. Recorded videos were randomly distributed in a single-blind manner in order to be evaluated by four otorhinolaryngologists, who answered a questionnaire comprising three questions. Statistical analysis was used to compare groups – which were defined by the use, or not, of protection cap – based on Wilcoxon nonparametric test. Statistical significance was set at 5% with 95% confidence interval. There was no statistically significant difference in image quality between examinations performed with, and without, protection cap (P= 0.646) or in the diagnosis confidence level of examinations performed with, or without, the barrier method. The use of disposable protection cap on intraoral dental camera did not significantly change the quality of images taken through videolaryngoscopy performed with 70° rigid optics in vocally healthy patients. The Voice Foundation. Published by Elsevier Inc. 2023-01 2020-11-02 /pmc/articles/PMC7605857/ /pubmed/33168360 http://dx.doi.org/10.1016/j.jvoice.2020.10.014 Text en © 2020 The Voice Foundation. Published by Elsevier Inc. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Nagata Cavalheiro, Mariana Fonseca, Vinicius Ribas Zeigelboim, Bianca Simone Costa, Diego F. de Lima, Lucas Viomar Bozzo, Marlon Kleber Tonochi, Rita de Cássia Hartmann, Bruno Ceron Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19 |
title | Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19 |
title_full | Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19 |
title_fullStr | Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19 |
title_full_unstemmed | Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19 |
title_short | Evaluating the Quality of Rigid Optic Videolaryngoscopy Image Taken Through Dental Protection Cap and Its Feasibility as Additional Barrier Method Against COVID-19 |
title_sort | evaluating the quality of rigid optic videolaryngoscopy image taken through dental protection cap and its feasibility as additional barrier method against covid-19 |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605857/ https://www.ncbi.nlm.nih.gov/pubmed/33168360 http://dx.doi.org/10.1016/j.jvoice.2020.10.014 |
work_keys_str_mv | AT nagatacavalheiromariana evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 AT fonsecaviniciusribas evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 AT zeigelboimbiancasimone evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 AT costadiegof evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 AT delimalucasviomar evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 AT bozzomarlonkleber evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 AT tonochiritadecassia evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 AT hartmannbrunoceron evaluatingthequalityofrigidopticvideolaryngoscopyimagetakenthroughdentalprotectioncapanditsfeasibilityasadditionalbarriermethodagainstcovid19 |