Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
PURPOSE: The purpose of this study was to correlate between the axial length of the globe and the insertion site of horizontal extraocular muscles using swept-source anterior segment optical coherence tomography (SS-ASOCT), with posing an equation to calculate the muscle insertion site from the axia...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605956/ https://www.ncbi.nlm.nih.gov/pubmed/33154617 http://dx.doi.org/10.2147/OPTH.S262916 |
_version_ | 1783604412381396992 |
---|---|
author | El-Fayoumi, Dina Bahgat, Nermeen Khafagy, Mohamed Hatata, Ragai Sabry, Dalia Allam, Ghada Kasem, Manal Ali Sadek, Sherin |
author_facet | El-Fayoumi, Dina Bahgat, Nermeen Khafagy, Mohamed Hatata, Ragai Sabry, Dalia Allam, Ghada Kasem, Manal Ali Sadek, Sherin |
author_sort | El-Fayoumi, Dina |
collection | PubMed |
description | PURPOSE: The purpose of this study was to correlate between the axial length of the globe and the insertion site of horizontal extraocular muscles using swept-source anterior segment optical coherence tomography (SS-ASOCT), with posing an equation to calculate the muscle insertion site from the axial length. METHODS: The study design was observational and cross-sectional. It was performed on 157 eyes of 157 healthy subjects. The distance of the medial rectus (MR) and the lateral rectus (LR) insertion sites from the limbus were measured using SS-ASOCT. The insertion sites’ distances were correlated to the axial length (hypermetropes < 22.5 mm, myopes > 24.5). Correlation between numerical variables was done by Pearson’s correlation coefficient and confirmed by linear regression analysis and scatter diagrams. RESULTS: The mean MR insertion site was 5.47 ± 0.19 mm in hypermetropes versus 5.68 ± 0.23 mm in myopes, whereas the mean LR insertion site was 6.81± 0.23 mm in hyperopes versus 7.08 ± 0.16 mm in myopes. The axial length showed a moderate positive, but significant, correlation to the insertional position for the medial and lateral rectus muscles (MR: r=0.417, p<0.001; LR: r=0.410, p<0.001). CONCLUSION: Comparing the horizontal extraocular muscle insertion site to axial length using SS-ASOCT showed a significant positive correlation. The model equation for MR insertion: MR (mm) = 4.522 + 0.045 (AXL in mm) with an R = 0.437, R(2)= 0.191, F=12.071, P<0.001. The model equation for LR insertion: LR (mm) = 5.72 + 0.048 (AXL in mm) with an R = 0.438, R(2)= 0.192, F=12.116, P<0.001. |
format | Online Article Text |
id | pubmed-7605956 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-76059562020-11-04 Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT El-Fayoumi, Dina Bahgat, Nermeen Khafagy, Mohamed Hatata, Ragai Sabry, Dalia Allam, Ghada Kasem, Manal Ali Sadek, Sherin Clin Ophthalmol Original Research PURPOSE: The purpose of this study was to correlate between the axial length of the globe and the insertion site of horizontal extraocular muscles using swept-source anterior segment optical coherence tomography (SS-ASOCT), with posing an equation to calculate the muscle insertion site from the axial length. METHODS: The study design was observational and cross-sectional. It was performed on 157 eyes of 157 healthy subjects. The distance of the medial rectus (MR) and the lateral rectus (LR) insertion sites from the limbus were measured using SS-ASOCT. The insertion sites’ distances were correlated to the axial length (hypermetropes < 22.5 mm, myopes > 24.5). Correlation between numerical variables was done by Pearson’s correlation coefficient and confirmed by linear regression analysis and scatter diagrams. RESULTS: The mean MR insertion site was 5.47 ± 0.19 mm in hypermetropes versus 5.68 ± 0.23 mm in myopes, whereas the mean LR insertion site was 6.81± 0.23 mm in hyperopes versus 7.08 ± 0.16 mm in myopes. The axial length showed a moderate positive, but significant, correlation to the insertional position for the medial and lateral rectus muscles (MR: r=0.417, p<0.001; LR: r=0.410, p<0.001). CONCLUSION: Comparing the horizontal extraocular muscle insertion site to axial length using SS-ASOCT showed a significant positive correlation. The model equation for MR insertion: MR (mm) = 4.522 + 0.045 (AXL in mm) with an R = 0.437, R(2)= 0.191, F=12.071, P<0.001. The model equation for LR insertion: LR (mm) = 5.72 + 0.048 (AXL in mm) with an R = 0.438, R(2)= 0.192, F=12.116, P<0.001. Dove 2020-10-29 /pmc/articles/PMC7605956/ /pubmed/33154617 http://dx.doi.org/10.2147/OPTH.S262916 Text en © 2020 El-Fayoumi et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research El-Fayoumi, Dina Bahgat, Nermeen Khafagy, Mohamed Hatata, Ragai Sabry, Dalia Allam, Ghada Kasem, Manal Ali Sadek, Sherin Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT |
title | Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT |
title_full | Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT |
title_fullStr | Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT |
title_full_unstemmed | Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT |
title_short | Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT |
title_sort | horizontal extraocular muscle insertion site in relation to axial length using swept-source anterior segment oct |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605956/ https://www.ncbi.nlm.nih.gov/pubmed/33154617 http://dx.doi.org/10.2147/OPTH.S262916 |
work_keys_str_mv | AT elfayoumidina horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct AT bahgatnermeen horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct AT khafagymohamed horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct AT hatataragai horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct AT sabrydalia horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct AT allamghada horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct AT kasemmanalali horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct AT sadeksherin horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct |