Cargando…

Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT

PURPOSE: The purpose of this study was to correlate between the axial length of the globe and the insertion site of horizontal extraocular muscles using swept-source anterior segment optical coherence tomography (SS-ASOCT), with posing an equation to calculate the muscle insertion site from the axia...

Descripción completa

Detalles Bibliográficos
Autores principales: El-Fayoumi, Dina, Bahgat, Nermeen, Khafagy, Mohamed, Hatata, Ragai, Sabry, Dalia, Allam, Ghada, Kasem, Manal Ali, Sadek, Sherin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605956/
https://www.ncbi.nlm.nih.gov/pubmed/33154617
http://dx.doi.org/10.2147/OPTH.S262916
_version_ 1783604412381396992
author El-Fayoumi, Dina
Bahgat, Nermeen
Khafagy, Mohamed
Hatata, Ragai
Sabry, Dalia
Allam, Ghada
Kasem, Manal Ali
Sadek, Sherin
author_facet El-Fayoumi, Dina
Bahgat, Nermeen
Khafagy, Mohamed
Hatata, Ragai
Sabry, Dalia
Allam, Ghada
Kasem, Manal Ali
Sadek, Sherin
author_sort El-Fayoumi, Dina
collection PubMed
description PURPOSE: The purpose of this study was to correlate between the axial length of the globe and the insertion site of horizontal extraocular muscles using swept-source anterior segment optical coherence tomography (SS-ASOCT), with posing an equation to calculate the muscle insertion site from the axial length. METHODS: The study design was observational and cross-sectional. It was performed on 157 eyes of 157 healthy subjects. The distance of the medial rectus (MR) and the lateral rectus (LR) insertion sites from the limbus were measured using SS-ASOCT. The insertion sites’ distances were correlated to the axial length (hypermetropes < 22.5 mm, myopes > 24.5). Correlation between numerical variables was done by Pearson’s correlation coefficient and confirmed by linear regression analysis and scatter diagrams. RESULTS: The mean MR insertion site was 5.47 ± 0.19 mm in hypermetropes versus 5.68 ± 0.23 mm in myopes, whereas the mean LR insertion site was 6.81± 0.23 mm in hyperopes versus 7.08 ± 0.16 mm in myopes. The axial length showed a moderate positive, but significant, correlation to the insertional position for the medial and lateral rectus muscles (MR: r=0.417, p<0.001; LR: r=0.410, p<0.001). CONCLUSION: Comparing the horizontal extraocular muscle insertion site to axial length using SS-ASOCT showed a significant positive correlation. The model equation for MR insertion: MR (mm) = 4.522 + 0.045 (AXL in mm) with an R = 0.437, R(2)= 0.191, F=12.071, P<0.001. The model equation for LR insertion: LR (mm) = 5.72 + 0.048 (AXL in mm) with an R = 0.438, R(2)= 0.192, F=12.116, P<0.001.
format Online
Article
Text
id pubmed-7605956
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-76059562020-11-04 Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT El-Fayoumi, Dina Bahgat, Nermeen Khafagy, Mohamed Hatata, Ragai Sabry, Dalia Allam, Ghada Kasem, Manal Ali Sadek, Sherin Clin Ophthalmol Original Research PURPOSE: The purpose of this study was to correlate between the axial length of the globe and the insertion site of horizontal extraocular muscles using swept-source anterior segment optical coherence tomography (SS-ASOCT), with posing an equation to calculate the muscle insertion site from the axial length. METHODS: The study design was observational and cross-sectional. It was performed on 157 eyes of 157 healthy subjects. The distance of the medial rectus (MR) and the lateral rectus (LR) insertion sites from the limbus were measured using SS-ASOCT. The insertion sites’ distances were correlated to the axial length (hypermetropes < 22.5 mm, myopes > 24.5). Correlation between numerical variables was done by Pearson’s correlation coefficient and confirmed by linear regression analysis and scatter diagrams. RESULTS: The mean MR insertion site was 5.47 ± 0.19 mm in hypermetropes versus 5.68 ± 0.23 mm in myopes, whereas the mean LR insertion site was 6.81± 0.23 mm in hyperopes versus 7.08 ± 0.16 mm in myopes. The axial length showed a moderate positive, but significant, correlation to the insertional position for the medial and lateral rectus muscles (MR: r=0.417, p<0.001; LR: r=0.410, p<0.001). CONCLUSION: Comparing the horizontal extraocular muscle insertion site to axial length using SS-ASOCT showed a significant positive correlation. The model equation for MR insertion: MR (mm) = 4.522 + 0.045 (AXL in mm) with an R = 0.437, R(2)= 0.191, F=12.071, P<0.001. The model equation for LR insertion: LR (mm) = 5.72 + 0.048 (AXL in mm) with an R = 0.438, R(2)= 0.192, F=12.116, P<0.001. Dove 2020-10-29 /pmc/articles/PMC7605956/ /pubmed/33154617 http://dx.doi.org/10.2147/OPTH.S262916 Text en © 2020 El-Fayoumi et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
El-Fayoumi, Dina
Bahgat, Nermeen
Khafagy, Mohamed
Hatata, Ragai
Sabry, Dalia
Allam, Ghada
Kasem, Manal Ali
Sadek, Sherin
Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
title Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
title_full Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
title_fullStr Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
title_full_unstemmed Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
title_short Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
title_sort horizontal extraocular muscle insertion site in relation to axial length using swept-source anterior segment oct
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605956/
https://www.ncbi.nlm.nih.gov/pubmed/33154617
http://dx.doi.org/10.2147/OPTH.S262916
work_keys_str_mv AT elfayoumidina horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct
AT bahgatnermeen horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct
AT khafagymohamed horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct
AT hatataragai horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct
AT sabrydalia horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct
AT allamghada horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct
AT kasemmanalali horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct
AT sadeksherin horizontalextraocularmuscleinsertionsiteinrelationtoaxiallengthusingsweptsourceanteriorsegmentoct