Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
PURPOSE: The aim of this study was to investigate whether data obtained from the Lilium α-200 (Lilium Otsuka Co., Ltd., Japan) correlated with conventional frequency-volume chart (FVC) and post-void residual urine volume (PVR) obtained by urethral catheterization. MATERIALS AND METHODS: This was a p...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Urological Association
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7606125/ https://www.ncbi.nlm.nih.gov/pubmed/33135404 http://dx.doi.org/10.4111/icu.20200012 |
_version_ | 1783604442189266944 |
---|---|
author | Majima, Tsuyoshi Oota, Yumi Matsukawa, Yoshihisa Funahashi, Yasuhito Kato, Masashi Mimata, Hiromitsu Gotoh, Momokazu |
author_facet | Majima, Tsuyoshi Oota, Yumi Matsukawa, Yoshihisa Funahashi, Yasuhito Kato, Masashi Mimata, Hiromitsu Gotoh, Momokazu |
author_sort | Majima, Tsuyoshi |
collection | PubMed |
description | PURPOSE: The aim of this study was to investigate whether data obtained from the Lilium α-200 (Lilium Otsuka Co., Ltd., Japan) correlated with conventional frequency-volume chart (FVC) and post-void residual urine volume (PVR) obtained by urethral catheterization. MATERIALS AND METHODS: This was a prospective multicentre study. Patients hospitalized for the treatment of lower urinary tract symptoms were included. Patients were evaluated with conventional FVC and Lilium α-200 for 2 days. PVR was measured by urethral catherization after urination at the end of the 2 day evaluation period. RESULTS: A total of 42 patients were enrolled in this study. Voided volume and PVR measured by Lilium α-200 were significantly correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, respectively. There was considerable measurement error in voided volume measured by Lilium α-200 (−21.0±102.0 mL). In contrast, the error between PVR measured by the Lilium α-200 and PVR obtained by urethral catheterization was 2.4±52.0 mL. Additionally, high body mass index, but not sex, benign prostate hyperplasia, time zone of measurement (daytime vs. nighttime), and examiners (a urologist versus other healthcare providers) were significantly associated with inaccurate results in voided volume. CONCLUSIONS: Voided volume and PVR measured by the Lilium α-200 were correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, although accuracy of the measurements was not high. The Lilium α-200 is a useful device to easily measure approximate bladder volume. |
format | Online Article Text |
id | pubmed-7606125 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Korean Urological Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-76061252020-11-05 Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement Majima, Tsuyoshi Oota, Yumi Matsukawa, Yoshihisa Funahashi, Yasuhito Kato, Masashi Mimata, Hiromitsu Gotoh, Momokazu Investig Clin Urol Innovations in Urology PURPOSE: The aim of this study was to investigate whether data obtained from the Lilium α-200 (Lilium Otsuka Co., Ltd., Japan) correlated with conventional frequency-volume chart (FVC) and post-void residual urine volume (PVR) obtained by urethral catheterization. MATERIALS AND METHODS: This was a prospective multicentre study. Patients hospitalized for the treatment of lower urinary tract symptoms were included. Patients were evaluated with conventional FVC and Lilium α-200 for 2 days. PVR was measured by urethral catherization after urination at the end of the 2 day evaluation period. RESULTS: A total of 42 patients were enrolled in this study. Voided volume and PVR measured by Lilium α-200 were significantly correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, respectively. There was considerable measurement error in voided volume measured by Lilium α-200 (−21.0±102.0 mL). In contrast, the error between PVR measured by the Lilium α-200 and PVR obtained by urethral catheterization was 2.4±52.0 mL. Additionally, high body mass index, but not sex, benign prostate hyperplasia, time zone of measurement (daytime vs. nighttime), and examiners (a urologist versus other healthcare providers) were significantly associated with inaccurate results in voided volume. CONCLUSIONS: Voided volume and PVR measured by the Lilium α-200 were correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, although accuracy of the measurements was not high. The Lilium α-200 is a useful device to easily measure approximate bladder volume. The Korean Urological Association 2020-11 2020-10-05 /pmc/articles/PMC7606125/ /pubmed/33135404 http://dx.doi.org/10.4111/icu.20200012 Text en © The Korean Urological Association, 2020 http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Innovations in Urology Majima, Tsuyoshi Oota, Yumi Matsukawa, Yoshihisa Funahashi, Yasuhito Kato, Masashi Mimata, Hiromitsu Gotoh, Momokazu Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement |
title | Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement |
title_full | Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement |
title_fullStr | Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement |
title_full_unstemmed | Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement |
title_short | Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement |
title_sort | feasibility of the lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement |
topic | Innovations in Urology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7606125/ https://www.ncbi.nlm.nih.gov/pubmed/33135404 http://dx.doi.org/10.4111/icu.20200012 |
work_keys_str_mv | AT majimatsuyoshi feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement AT ootayumi feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement AT matsukawayoshihisa feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement AT funahashiyasuhito feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement AT katomasashi feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement AT mimatahiromitsu feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement AT gotohmomokazu feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement |