Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement

PURPOSE: The aim of this study was to investigate whether data obtained from the Lilium α-200 (Lilium Otsuka Co., Ltd., Japan) correlated with conventional frequency-volume chart (FVC) and post-void residual urine volume (PVR) obtained by urethral catheterization. MATERIALS AND METHODS: This was a p...

Descripción completa

Detalles Bibliográficos
Autores principales: Majima, Tsuyoshi, Oota, Yumi, Matsukawa, Yoshihisa, Funahashi, Yasuhito, Kato, Masashi, Mimata, Hiromitsu, Gotoh, Momokazu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Urological Association 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7606125/
https://www.ncbi.nlm.nih.gov/pubmed/33135404
http://dx.doi.org/10.4111/icu.20200012
_version_ 1783604442189266944
author Majima, Tsuyoshi
Oota, Yumi
Matsukawa, Yoshihisa
Funahashi, Yasuhito
Kato, Masashi
Mimata, Hiromitsu
Gotoh, Momokazu
author_facet Majima, Tsuyoshi
Oota, Yumi
Matsukawa, Yoshihisa
Funahashi, Yasuhito
Kato, Masashi
Mimata, Hiromitsu
Gotoh, Momokazu
author_sort Majima, Tsuyoshi
collection PubMed
description PURPOSE: The aim of this study was to investigate whether data obtained from the Lilium α-200 (Lilium Otsuka Co., Ltd., Japan) correlated with conventional frequency-volume chart (FVC) and post-void residual urine volume (PVR) obtained by urethral catheterization. MATERIALS AND METHODS: This was a prospective multicentre study. Patients hospitalized for the treatment of lower urinary tract symptoms were included. Patients were evaluated with conventional FVC and Lilium α-200 for 2 days. PVR was measured by urethral catherization after urination at the end of the 2 day evaluation period. RESULTS: A total of 42 patients were enrolled in this study. Voided volume and PVR measured by Lilium α-200 were significantly correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, respectively. There was considerable measurement error in voided volume measured by Lilium α-200 (−21.0±102.0 mL). In contrast, the error between PVR measured by the Lilium α-200 and PVR obtained by urethral catheterization was 2.4±52.0 mL. Additionally, high body mass index, but not sex, benign prostate hyperplasia, time zone of measurement (daytime vs. nighttime), and examiners (a urologist versus other healthcare providers) were significantly associated with inaccurate results in voided volume. CONCLUSIONS: Voided volume and PVR measured by the Lilium α-200 were correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, although accuracy of the measurements was not high. The Lilium α-200 is a useful device to easily measure approximate bladder volume.
format Online
Article
Text
id pubmed-7606125
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Urological Association
record_format MEDLINE/PubMed
spelling pubmed-76061252020-11-05 Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement Majima, Tsuyoshi Oota, Yumi Matsukawa, Yoshihisa Funahashi, Yasuhito Kato, Masashi Mimata, Hiromitsu Gotoh, Momokazu Investig Clin Urol Innovations in Urology PURPOSE: The aim of this study was to investigate whether data obtained from the Lilium α-200 (Lilium Otsuka Co., Ltd., Japan) correlated with conventional frequency-volume chart (FVC) and post-void residual urine volume (PVR) obtained by urethral catheterization. MATERIALS AND METHODS: This was a prospective multicentre study. Patients hospitalized for the treatment of lower urinary tract symptoms were included. Patients were evaluated with conventional FVC and Lilium α-200 for 2 days. PVR was measured by urethral catherization after urination at the end of the 2 day evaluation period. RESULTS: A total of 42 patients were enrolled in this study. Voided volume and PVR measured by Lilium α-200 were significantly correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, respectively. There was considerable measurement error in voided volume measured by Lilium α-200 (−21.0±102.0 mL). In contrast, the error between PVR measured by the Lilium α-200 and PVR obtained by urethral catheterization was 2.4±52.0 mL. Additionally, high body mass index, but not sex, benign prostate hyperplasia, time zone of measurement (daytime vs. nighttime), and examiners (a urologist versus other healthcare providers) were significantly associated with inaccurate results in voided volume. CONCLUSIONS: Voided volume and PVR measured by the Lilium α-200 were correlated with voided volume obtained from conventional FVC and PVR measured by urethral catheterization, although accuracy of the measurements was not high. The Lilium α-200 is a useful device to easily measure approximate bladder volume. The Korean Urological Association 2020-11 2020-10-05 /pmc/articles/PMC7606125/ /pubmed/33135404 http://dx.doi.org/10.4111/icu.20200012 Text en © The Korean Urological Association, 2020 http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Innovations in Urology
Majima, Tsuyoshi
Oota, Yumi
Matsukawa, Yoshihisa
Funahashi, Yasuhito
Kato, Masashi
Mimata, Hiromitsu
Gotoh, Momokazu
Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
title Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
title_full Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
title_fullStr Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
title_full_unstemmed Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
title_short Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
title_sort feasibility of the lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement
topic Innovations in Urology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7606125/
https://www.ncbi.nlm.nih.gov/pubmed/33135404
http://dx.doi.org/10.4111/icu.20200012
work_keys_str_mv AT majimatsuyoshi feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement
AT ootayumi feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement
AT matsukawayoshihisa feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement
AT funahashiyasuhito feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement
AT katomasashi feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement
AT mimatahiromitsu feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement
AT gotohmomokazu feasibilityoftheliliuma200portableultrasoundbladderscannerforaccuratebladdervolumemeasurement