Cargando…

A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation

An ultrasensitive DNA electrochemical biosensor based on the carbon paste electrode (CPE) amplified with ZIF-8 and 1-butyl-3-methylimidazolium methanesulfonate (BMIMS) was fabricated in this research. The DNA/BMIMS/ZIF-8/CPE was used for the selective determination of a mitoxantrone anticancer drug...

Descripción completa

Detalles Bibliográficos
Autores principales: Alizadeh, Marzieh, Azar, Parviz Aberoomand, Mozaffari, Sayed Ahmad, Karimi-Maleh, Hassan, Tamaddon, Ali-Mohammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7606923/
https://www.ncbi.nlm.nih.gov/pubmed/33195033
http://dx.doi.org/10.3389/fchem.2020.00814
_version_ 1783604534999777280
author Alizadeh, Marzieh
Azar, Parviz Aberoomand
Mozaffari, Sayed Ahmad
Karimi-Maleh, Hassan
Tamaddon, Ali-Mohammad
author_facet Alizadeh, Marzieh
Azar, Parviz Aberoomand
Mozaffari, Sayed Ahmad
Karimi-Maleh, Hassan
Tamaddon, Ali-Mohammad
author_sort Alizadeh, Marzieh
collection PubMed
description An ultrasensitive DNA electrochemical biosensor based on the carbon paste electrode (CPE) amplified with ZIF-8 and 1-butyl-3-methylimidazolium methanesulfonate (BMIMS) was fabricated in this research. The DNA/BMIMS/ZIF-8/CPE was used for the selective determination of a mitoxantrone anticancer drug in aqueous solution, resulting in a good catalytic effect and a powerful ability for determining mitoxantrone. Also, the interaction of the mitoxantrone anticancer drug with guanine bases of ds-DNA was used as a powerful strategy in the suggested biosensor, which was confirmed with docking investigation. Docking study of mitoxantrone into the ds-DNA sequence showed the intercalative binding mode of mitoxantrone into the nitrogenous-based pairs of ds-DNA. The effective factors such as ds-DNA concentration, temperature, buffer types, and incubation time were also optimized for the fabricated mitoxantrone biosensor. The results showed that, under optimum conditions (T = 25°C; incubation time=12 min; pH= 4.8 acetate buffer solution and [DNA] = 50 mg/L), the DNA/BMIMS/ZIF-8/CPE could be used in mitoxantrone assay in a concentration ranging from 8.0 nM to 110 μM with a detection limit of 3.0 nM. In addition, recovery data between 99.18 and 102.08% were obtained for the determination of mitoxantrone in the injection samples using DNA/ZIF-8/BMIMF/CPE as powerful biosensors.
format Online
Article
Text
id pubmed-7606923
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-76069232020-11-13 A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation Alizadeh, Marzieh Azar, Parviz Aberoomand Mozaffari, Sayed Ahmad Karimi-Maleh, Hassan Tamaddon, Ali-Mohammad Front Chem Chemistry An ultrasensitive DNA electrochemical biosensor based on the carbon paste electrode (CPE) amplified with ZIF-8 and 1-butyl-3-methylimidazolium methanesulfonate (BMIMS) was fabricated in this research. The DNA/BMIMS/ZIF-8/CPE was used for the selective determination of a mitoxantrone anticancer drug in aqueous solution, resulting in a good catalytic effect and a powerful ability for determining mitoxantrone. Also, the interaction of the mitoxantrone anticancer drug with guanine bases of ds-DNA was used as a powerful strategy in the suggested biosensor, which was confirmed with docking investigation. Docking study of mitoxantrone into the ds-DNA sequence showed the intercalative binding mode of mitoxantrone into the nitrogenous-based pairs of ds-DNA. The effective factors such as ds-DNA concentration, temperature, buffer types, and incubation time were also optimized for the fabricated mitoxantrone biosensor. The results showed that, under optimum conditions (T = 25°C; incubation time=12 min; pH= 4.8 acetate buffer solution and [DNA] = 50 mg/L), the DNA/BMIMS/ZIF-8/CPE could be used in mitoxantrone assay in a concentration ranging from 8.0 nM to 110 μM with a detection limit of 3.0 nM. In addition, recovery data between 99.18 and 102.08% were obtained for the determination of mitoxantrone in the injection samples using DNA/ZIF-8/BMIMF/CPE as powerful biosensors. Frontiers Media S.A. 2020-10-20 /pmc/articles/PMC7606923/ /pubmed/33195033 http://dx.doi.org/10.3389/fchem.2020.00814 Text en Copyright © 2020 Alizadeh, Azar, Mozaffari, Karimi-Maleh and Tamaddon. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Chemistry
Alizadeh, Marzieh
Azar, Parviz Aberoomand
Mozaffari, Sayed Ahmad
Karimi-Maleh, Hassan
Tamaddon, Ali-Mohammad
A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation
title A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation
title_full A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation
title_fullStr A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation
title_full_unstemmed A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation
title_short A DNA Based Biosensor Amplified With ZIF-8/Ionic Liquid Composite for Determination of Mitoxantrone Anticancer Drug: An Experimental/Docking Investigation
title_sort dna based biosensor amplified with zif-8/ionic liquid composite for determination of mitoxantrone anticancer drug: an experimental/docking investigation
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7606923/
https://www.ncbi.nlm.nih.gov/pubmed/33195033
http://dx.doi.org/10.3389/fchem.2020.00814
work_keys_str_mv AT alizadehmarzieh adnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT azarparvizaberoomand adnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT mozaffarisayedahmad adnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT karimimalehhassan adnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT tamaddonalimohammad adnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT alizadehmarzieh dnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT azarparvizaberoomand dnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT mozaffarisayedahmad dnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT karimimalehhassan dnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation
AT tamaddonalimohammad dnabasedbiosensoramplifiedwithzif8ionicliquidcompositefordeterminationofmitoxantroneanticancerdruganexperimentaldockinginvestigation