Cargando…
Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock
OBJECTIVES: The aim of this study was to investigate the impact of acute left ventricular unloading by percutaneous left ventricular assist device on pulmonary congestion and pneumonia in patients with cardiogenic shock (CS). METHODS: In this retrospective study, we analysed patients with CS who rec...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7607612/ https://www.ncbi.nlm.nih.gov/pubmed/33132209 http://dx.doi.org/10.1136/openhrt-2020-001385 |
_version_ | 1783604675475406848 |
---|---|
author | Haberkorn, Sandra Uwarow, Angelika Haurand, Jean Jung, Christian Kelm, Malte Westenfeld, Ralf Horn, Patrick |
author_facet | Haberkorn, Sandra Uwarow, Angelika Haurand, Jean Jung, Christian Kelm, Malte Westenfeld, Ralf Horn, Patrick |
author_sort | Haberkorn, Sandra |
collection | PubMed |
description | OBJECTIVES: The aim of this study was to investigate the impact of acute left ventricular unloading by percutaneous left ventricular assist device on pulmonary congestion and pneumonia in patients with cardiogenic shock (CS). METHODS: In this retrospective study, we analysed patients with CS who received the Impella percutaneous left ventricular assist device (n=50) compared with those who received intra-aortic balloon pump (IABP) support (n=50). Pulmonary congestion was longitudinally assessed while on support by calculating characteristic findings on the chest X-ray using the Halperin score. The rate of pneumonia and early mortality were assessed as a secondary endpoint. RESULTS: The groups (Impella vs IABP) did not differ in terms of age, Sequential Organ Failure Assessment (SOFA) score, Acute Physiology, Chronic Health Evaluation (APACHE) II score or serum lactate levels. Pulmonary congestion decreased in patient treated with Impella at each time point postimplantation. No change in congestion status was observed in patients supported with IABP. Multivariate analysis indicated Impella support as an independent predictor for pulmonary decongestion (OR 4.06, 95% CI 1.15 to 14.35, p=0.030). The rate of early pneumonia was lower in the Impella group compared with the IABP group (54% vs 74%, p=0.037). Failure of pulmonary decongestion during mechanical circulatory support independently predicted early pneumonia (OR 0.28, 95% CI 0.12 to 0.70, p=0.006). CONCLUSION: Pulmonary decongestion may facilitate treatment of pneumonia in patients with CS. Left ventricular unloading by Impella device might support pulmonary decongestion, although a larger prospective trial in this patient population is required. |
format | Online Article Text |
id | pubmed-7607612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-76076122020-11-12 Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock Haberkorn, Sandra Uwarow, Angelika Haurand, Jean Jung, Christian Kelm, Malte Westenfeld, Ralf Horn, Patrick Open Heart Heart Failure and Cardiomyopathies OBJECTIVES: The aim of this study was to investigate the impact of acute left ventricular unloading by percutaneous left ventricular assist device on pulmonary congestion and pneumonia in patients with cardiogenic shock (CS). METHODS: In this retrospective study, we analysed patients with CS who received the Impella percutaneous left ventricular assist device (n=50) compared with those who received intra-aortic balloon pump (IABP) support (n=50). Pulmonary congestion was longitudinally assessed while on support by calculating characteristic findings on the chest X-ray using the Halperin score. The rate of pneumonia and early mortality were assessed as a secondary endpoint. RESULTS: The groups (Impella vs IABP) did not differ in terms of age, Sequential Organ Failure Assessment (SOFA) score, Acute Physiology, Chronic Health Evaluation (APACHE) II score or serum lactate levels. Pulmonary congestion decreased in patient treated with Impella at each time point postimplantation. No change in congestion status was observed in patients supported with IABP. Multivariate analysis indicated Impella support as an independent predictor for pulmonary decongestion (OR 4.06, 95% CI 1.15 to 14.35, p=0.030). The rate of early pneumonia was lower in the Impella group compared with the IABP group (54% vs 74%, p=0.037). Failure of pulmonary decongestion during mechanical circulatory support independently predicted early pneumonia (OR 0.28, 95% CI 0.12 to 0.70, p=0.006). CONCLUSION: Pulmonary decongestion may facilitate treatment of pneumonia in patients with CS. Left ventricular unloading by Impella device might support pulmonary decongestion, although a larger prospective trial in this patient population is required. BMJ Publishing Group 2020-11-01 /pmc/articles/PMC7607612/ /pubmed/33132209 http://dx.doi.org/10.1136/openhrt-2020-001385 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Heart Failure and Cardiomyopathies Haberkorn, Sandra Uwarow, Angelika Haurand, Jean Jung, Christian Kelm, Malte Westenfeld, Ralf Horn, Patrick Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock |
title | Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock |
title_full | Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock |
title_fullStr | Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock |
title_full_unstemmed | Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock |
title_short | Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock |
title_sort | percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock |
topic | Heart Failure and Cardiomyopathies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7607612/ https://www.ncbi.nlm.nih.gov/pubmed/33132209 http://dx.doi.org/10.1136/openhrt-2020-001385 |
work_keys_str_mv | AT haberkornsandra percutaneousleftventricularassistsupportisassociatedwithlesspulmonarycongestionandlowerrateofpneumoniainpatientswithcardiogenicshock AT uwarowangelika percutaneousleftventricularassistsupportisassociatedwithlesspulmonarycongestionandlowerrateofpneumoniainpatientswithcardiogenicshock AT haurandjean percutaneousleftventricularassistsupportisassociatedwithlesspulmonarycongestionandlowerrateofpneumoniainpatientswithcardiogenicshock AT jungchristian percutaneousleftventricularassistsupportisassociatedwithlesspulmonarycongestionandlowerrateofpneumoniainpatientswithcardiogenicshock AT kelmmalte percutaneousleftventricularassistsupportisassociatedwithlesspulmonarycongestionandlowerrateofpneumoniainpatientswithcardiogenicshock AT westenfeldralf percutaneousleftventricularassistsupportisassociatedwithlesspulmonarycongestionandlowerrateofpneumoniainpatientswithcardiogenicshock AT hornpatrick percutaneousleftventricularassistsupportisassociatedwithlesspulmonarycongestionandlowerrateofpneumoniainpatientswithcardiogenicshock |