Cargando…

Changes in the corneal thickness and limbus after 1 year of scleral contact lens use

PURPOSE: To assess the physiological changes in the cornea over time in patients with irregular cornea fitted with Rose K2 XL gas-permeable scleral contact lenses. METHODS: Prospective study of 16 eyes of patients who did not tolerate gas-permeable corneal contact lenses and were fitted with Rose K2...

Descripción completa

Detalles Bibliográficos
Autores principales: de Luis Eguileor, Beatriz, Acera, Arantxa, Santamaría Carro, Alaitz, Feijoo Lera, Raquel, Escudero Argaluza, Julene, Etxebarria Ecenarro, Jaime
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7608222/
https://www.ncbi.nlm.nih.gov/pubmed/31822857
http://dx.doi.org/10.1038/s41433-019-0729-z
_version_ 1783604790438133760
author de Luis Eguileor, Beatriz
Acera, Arantxa
Santamaría Carro, Alaitz
Feijoo Lera, Raquel
Escudero Argaluza, Julene
Etxebarria Ecenarro, Jaime
author_facet de Luis Eguileor, Beatriz
Acera, Arantxa
Santamaría Carro, Alaitz
Feijoo Lera, Raquel
Escudero Argaluza, Julene
Etxebarria Ecenarro, Jaime
author_sort de Luis Eguileor, Beatriz
collection PubMed
description PURPOSE: To assess the physiological changes in the cornea over time in patients with irregular cornea fitted with Rose K2 XL gas-permeable scleral contact lenses. METHODS: Prospective study of 16 eyes of patients who did not tolerate gas-permeable corneal contact lenses and were fitted with Rose K2 XL scleral lenses. We assessed the central vault and the corneal thickness centrally and at peripheral regions (2 to 5 mm annulus). All these measures were obtained by anterior segment optical coherence tomography. The measurements were taken immediately after fitting the lenses and 1, 6 and 12 months later. Prior to the study and at 1 year, we performed an objective test for diagnosing limbal stem cell deficiency (Limbokit). RESULTS: The mean vault was 201.7 ± 82.3 µm 20 min after fitting the contact lens; 189.4 ± 94.0 µm at 1 month; 165.1 ± 75.9 µm at 6 months and 142.1 ± 76.8 µm at 1 year, the values at 6 and 12 months being significantly different to baseline. After 1 year, the central corneal thickness had increased by 2.3% (IQR = 5.6), but the changes were only significant for the superior thickness. There is no limbal stem cell deficiency after 1 year of scleral contact lens use. CONCLUSIONS: After use of Rose K2 XL scleral contact lenses, the corneal physiology of patients with an irregular cornea remains unchanged, as assessed by corneal thickness measurements and the Limbokit test. In all cases, however, the vault decreased over time.
format Online
Article
Text
id pubmed-7608222
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-76082222020-11-05 Changes in the corneal thickness and limbus after 1 year of scleral contact lens use de Luis Eguileor, Beatriz Acera, Arantxa Santamaría Carro, Alaitz Feijoo Lera, Raquel Escudero Argaluza, Julene Etxebarria Ecenarro, Jaime Eye (Lond) Article PURPOSE: To assess the physiological changes in the cornea over time in patients with irregular cornea fitted with Rose K2 XL gas-permeable scleral contact lenses. METHODS: Prospective study of 16 eyes of patients who did not tolerate gas-permeable corneal contact lenses and were fitted with Rose K2 XL scleral lenses. We assessed the central vault and the corneal thickness centrally and at peripheral regions (2 to 5 mm annulus). All these measures were obtained by anterior segment optical coherence tomography. The measurements were taken immediately after fitting the lenses and 1, 6 and 12 months later. Prior to the study and at 1 year, we performed an objective test for diagnosing limbal stem cell deficiency (Limbokit). RESULTS: The mean vault was 201.7 ± 82.3 µm 20 min after fitting the contact lens; 189.4 ± 94.0 µm at 1 month; 165.1 ± 75.9 µm at 6 months and 142.1 ± 76.8 µm at 1 year, the values at 6 and 12 months being significantly different to baseline. After 1 year, the central corneal thickness had increased by 2.3% (IQR = 5.6), but the changes were only significant for the superior thickness. There is no limbal stem cell deficiency after 1 year of scleral contact lens use. CONCLUSIONS: After use of Rose K2 XL scleral contact lenses, the corneal physiology of patients with an irregular cornea remains unchanged, as assessed by corneal thickness measurements and the Limbokit test. In all cases, however, the vault decreased over time. Nature Publishing Group UK 2019-12-10 2020-09 /pmc/articles/PMC7608222/ /pubmed/31822857 http://dx.doi.org/10.1038/s41433-019-0729-z Text en © The Author(s), under exclusive licence to The Royal College of Ophthalmologists 2019
spellingShingle Article
de Luis Eguileor, Beatriz
Acera, Arantxa
Santamaría Carro, Alaitz
Feijoo Lera, Raquel
Escudero Argaluza, Julene
Etxebarria Ecenarro, Jaime
Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
title Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
title_full Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
title_fullStr Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
title_full_unstemmed Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
title_short Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
title_sort changes in the corneal thickness and limbus after 1 year of scleral contact lens use
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7608222/
https://www.ncbi.nlm.nih.gov/pubmed/31822857
http://dx.doi.org/10.1038/s41433-019-0729-z
work_keys_str_mv AT deluiseguileorbeatriz changesinthecornealthicknessandlimbusafter1yearofscleralcontactlensuse
AT aceraarantxa changesinthecornealthicknessandlimbusafter1yearofscleralcontactlensuse
AT santamariacarroalaitz changesinthecornealthicknessandlimbusafter1yearofscleralcontactlensuse
AT feijooleraraquel changesinthecornealthicknessandlimbusafter1yearofscleralcontactlensuse
AT escuderoargaluzajulene changesinthecornealthicknessandlimbusafter1yearofscleralcontactlensuse
AT etxebarriaecenarrojaime changesinthecornealthicknessandlimbusafter1yearofscleralcontactlensuse