Cargando…

Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center

AIMS/INTRODUCTION: In Japan, an insulin pump with predictive low‐glucose management (PLGM) was launched in 2018. It automatically suspends insulin delivery when the sensor detects or predicts low glucose values. The aim of this study was to analyze the safety and efficacy of PLGM in patients treated...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsunemi, Asako, Sato, Junko, Kurita, Mika, Wakabayashi, Yuka, Waseda, Naoko, Koshibu, Mami, Shinohara, Mai, Ozaki, Atsuko, Nakamura, Hiromi, Hirano, Naomi, Ikeda, Fuki, Satoh, Hiroaki, Watada, Hirotaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7610121/
https://www.ncbi.nlm.nih.gov/pubmed/32374513
http://dx.doi.org/10.1111/jdi.13288
_version_ 1783605138337824768
author Tsunemi, Asako
Sato, Junko
Kurita, Mika
Wakabayashi, Yuka
Waseda, Naoko
Koshibu, Mami
Shinohara, Mai
Ozaki, Atsuko
Nakamura, Hiromi
Hirano, Naomi
Ikeda, Fuki
Satoh, Hiroaki
Watada, Hirotaka
author_facet Tsunemi, Asako
Sato, Junko
Kurita, Mika
Wakabayashi, Yuka
Waseda, Naoko
Koshibu, Mami
Shinohara, Mai
Ozaki, Atsuko
Nakamura, Hiromi
Hirano, Naomi
Ikeda, Fuki
Satoh, Hiroaki
Watada, Hirotaka
author_sort Tsunemi, Asako
collection PubMed
description AIMS/INTRODUCTION: In Japan, an insulin pump with predictive low‐glucose management (PLGM) was launched in 2018. It automatically suspends insulin delivery when the sensor detects or predicts low glucose values. The aim of this study was to analyze the safety and efficacy of PLGM in patients treated in a Japanese center. MATERIALS AND METHODS: We carried out a retrospective observational analysis of 16 patients with type 1 diabetes mellitus and one patient after pancreatectomy. They switched from the MiniMed 620G device to the 640G device with PLGM. The primary outcome was the change in the percentage of time in hypoglycemia. The secondary outcome was the change in HbA1c (%) over a period of 3 months. We also explored the presence of “post‐suspend hyperglycemia” with the 640G device. RESULTS: After changing to the 640G device, the percentage of time in hypoglycemia (glucose <50 mg/dL) significantly decreased from 0.39% (0–1.51%) to 0% (0–0.44%; P = 0.0407). The percentage of time in hyperglycemia (glucose >180 mg/dL) significantly increased from 25.53% (15.78–44.14%) to 32.9% (24.71–45.49%; P = 0.0373). HbA1c significantly increased from 7.6 ± 1.0% to 7.8 ± 1.1% (P = 0.0161). From 1.5 to 4.5 h after the resumption of insulin delivery, the percentage of time in hyperglycemia was 32.23% (24.2–53.75%), but it was significantly lower, 2.78% (0–21.6%), when patients manually restarted the pump within 30 min compared with automatic resumption 31.2% (20–61.66%; P = 0.0063). CONCLUSIONS: Predictive low‐glucose management is an effective tool for reducing hypoglycemia, but possibly elicits “post‐suspend hyperglycemia.” This information is useful for achieving better blood glucose control in the patients treated with PLGM.
format Online
Article
Text
id pubmed-7610121
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-76101212020-11-09 Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center Tsunemi, Asako Sato, Junko Kurita, Mika Wakabayashi, Yuka Waseda, Naoko Koshibu, Mami Shinohara, Mai Ozaki, Atsuko Nakamura, Hiromi Hirano, Naomi Ikeda, Fuki Satoh, Hiroaki Watada, Hirotaka J Diabetes Investig Articles AIMS/INTRODUCTION: In Japan, an insulin pump with predictive low‐glucose management (PLGM) was launched in 2018. It automatically suspends insulin delivery when the sensor detects or predicts low glucose values. The aim of this study was to analyze the safety and efficacy of PLGM in patients treated in a Japanese center. MATERIALS AND METHODS: We carried out a retrospective observational analysis of 16 patients with type 1 diabetes mellitus and one patient after pancreatectomy. They switched from the MiniMed 620G device to the 640G device with PLGM. The primary outcome was the change in the percentage of time in hypoglycemia. The secondary outcome was the change in HbA1c (%) over a period of 3 months. We also explored the presence of “post‐suspend hyperglycemia” with the 640G device. RESULTS: After changing to the 640G device, the percentage of time in hypoglycemia (glucose <50 mg/dL) significantly decreased from 0.39% (0–1.51%) to 0% (0–0.44%; P = 0.0407). The percentage of time in hyperglycemia (glucose >180 mg/dL) significantly increased from 25.53% (15.78–44.14%) to 32.9% (24.71–45.49%; P = 0.0373). HbA1c significantly increased from 7.6 ± 1.0% to 7.8 ± 1.1% (P = 0.0161). From 1.5 to 4.5 h after the resumption of insulin delivery, the percentage of time in hyperglycemia was 32.23% (24.2–53.75%), but it was significantly lower, 2.78% (0–21.6%), when patients manually restarted the pump within 30 min compared with automatic resumption 31.2% (20–61.66%; P = 0.0063). CONCLUSIONS: Predictive low‐glucose management is an effective tool for reducing hypoglycemia, but possibly elicits “post‐suspend hyperglycemia.” This information is useful for achieving better blood glucose control in the patients treated with PLGM. John Wiley and Sons Inc. 2020-06-10 2020-11 /pmc/articles/PMC7610121/ /pubmed/32374513 http://dx.doi.org/10.1111/jdi.13288 Text en © 2020 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Articles
Tsunemi, Asako
Sato, Junko
Kurita, Mika
Wakabayashi, Yuka
Waseda, Naoko
Koshibu, Mami
Shinohara, Mai
Ozaki, Atsuko
Nakamura, Hiromi
Hirano, Naomi
Ikeda, Fuki
Satoh, Hiroaki
Watada, Hirotaka
Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center
title Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center
title_full Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center
title_fullStr Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center
title_full_unstemmed Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center
title_short Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center
title_sort effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: analysis of the patients treated in a japanese center
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7610121/
https://www.ncbi.nlm.nih.gov/pubmed/32374513
http://dx.doi.org/10.1111/jdi.13288
work_keys_str_mv AT tsunemiasako effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT satojunko effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT kuritamika effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT wakabayashiyuka effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT wasedanaoko effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT koshibumami effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT shinoharamai effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT ozakiatsuko effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT nakamurahiromi effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT hiranonaomi effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT ikedafuki effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT satohhiroaki effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter
AT watadahirotaka effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter