Cargando…
Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center
AIMS/INTRODUCTION: In Japan, an insulin pump with predictive low‐glucose management (PLGM) was launched in 2018. It automatically suspends insulin delivery when the sensor detects or predicts low glucose values. The aim of this study was to analyze the safety and efficacy of PLGM in patients treated...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7610121/ https://www.ncbi.nlm.nih.gov/pubmed/32374513 http://dx.doi.org/10.1111/jdi.13288 |
_version_ | 1783605138337824768 |
---|---|
author | Tsunemi, Asako Sato, Junko Kurita, Mika Wakabayashi, Yuka Waseda, Naoko Koshibu, Mami Shinohara, Mai Ozaki, Atsuko Nakamura, Hiromi Hirano, Naomi Ikeda, Fuki Satoh, Hiroaki Watada, Hirotaka |
author_facet | Tsunemi, Asako Sato, Junko Kurita, Mika Wakabayashi, Yuka Waseda, Naoko Koshibu, Mami Shinohara, Mai Ozaki, Atsuko Nakamura, Hiromi Hirano, Naomi Ikeda, Fuki Satoh, Hiroaki Watada, Hirotaka |
author_sort | Tsunemi, Asako |
collection | PubMed |
description | AIMS/INTRODUCTION: In Japan, an insulin pump with predictive low‐glucose management (PLGM) was launched in 2018. It automatically suspends insulin delivery when the sensor detects or predicts low glucose values. The aim of this study was to analyze the safety and efficacy of PLGM in patients treated in a Japanese center. MATERIALS AND METHODS: We carried out a retrospective observational analysis of 16 patients with type 1 diabetes mellitus and one patient after pancreatectomy. They switched from the MiniMed 620G device to the 640G device with PLGM. The primary outcome was the change in the percentage of time in hypoglycemia. The secondary outcome was the change in HbA1c (%) over a period of 3 months. We also explored the presence of “post‐suspend hyperglycemia” with the 640G device. RESULTS: After changing to the 640G device, the percentage of time in hypoglycemia (glucose <50 mg/dL) significantly decreased from 0.39% (0–1.51%) to 0% (0–0.44%; P = 0.0407). The percentage of time in hyperglycemia (glucose >180 mg/dL) significantly increased from 25.53% (15.78–44.14%) to 32.9% (24.71–45.49%; P = 0.0373). HbA1c significantly increased from 7.6 ± 1.0% to 7.8 ± 1.1% (P = 0.0161). From 1.5 to 4.5 h after the resumption of insulin delivery, the percentage of time in hyperglycemia was 32.23% (24.2–53.75%), but it was significantly lower, 2.78% (0–21.6%), when patients manually restarted the pump within 30 min compared with automatic resumption 31.2% (20–61.66%; P = 0.0063). CONCLUSIONS: Predictive low‐glucose management is an effective tool for reducing hypoglycemia, but possibly elicits “post‐suspend hyperglycemia.” This information is useful for achieving better blood glucose control in the patients treated with PLGM. |
format | Online Article Text |
id | pubmed-7610121 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-76101212020-11-09 Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center Tsunemi, Asako Sato, Junko Kurita, Mika Wakabayashi, Yuka Waseda, Naoko Koshibu, Mami Shinohara, Mai Ozaki, Atsuko Nakamura, Hiromi Hirano, Naomi Ikeda, Fuki Satoh, Hiroaki Watada, Hirotaka J Diabetes Investig Articles AIMS/INTRODUCTION: In Japan, an insulin pump with predictive low‐glucose management (PLGM) was launched in 2018. It automatically suspends insulin delivery when the sensor detects or predicts low glucose values. The aim of this study was to analyze the safety and efficacy of PLGM in patients treated in a Japanese center. MATERIALS AND METHODS: We carried out a retrospective observational analysis of 16 patients with type 1 diabetes mellitus and one patient after pancreatectomy. They switched from the MiniMed 620G device to the 640G device with PLGM. The primary outcome was the change in the percentage of time in hypoglycemia. The secondary outcome was the change in HbA1c (%) over a period of 3 months. We also explored the presence of “post‐suspend hyperglycemia” with the 640G device. RESULTS: After changing to the 640G device, the percentage of time in hypoglycemia (glucose <50 mg/dL) significantly decreased from 0.39% (0–1.51%) to 0% (0–0.44%; P = 0.0407). The percentage of time in hyperglycemia (glucose >180 mg/dL) significantly increased from 25.53% (15.78–44.14%) to 32.9% (24.71–45.49%; P = 0.0373). HbA1c significantly increased from 7.6 ± 1.0% to 7.8 ± 1.1% (P = 0.0161). From 1.5 to 4.5 h after the resumption of insulin delivery, the percentage of time in hyperglycemia was 32.23% (24.2–53.75%), but it was significantly lower, 2.78% (0–21.6%), when patients manually restarted the pump within 30 min compared with automatic resumption 31.2% (20–61.66%; P = 0.0063). CONCLUSIONS: Predictive low‐glucose management is an effective tool for reducing hypoglycemia, but possibly elicits “post‐suspend hyperglycemia.” This information is useful for achieving better blood glucose control in the patients treated with PLGM. John Wiley and Sons Inc. 2020-06-10 2020-11 /pmc/articles/PMC7610121/ /pubmed/32374513 http://dx.doi.org/10.1111/jdi.13288 Text en © 2020 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Articles Tsunemi, Asako Sato, Junko Kurita, Mika Wakabayashi, Yuka Waseda, Naoko Koshibu, Mami Shinohara, Mai Ozaki, Atsuko Nakamura, Hiromi Hirano, Naomi Ikeda, Fuki Satoh, Hiroaki Watada, Hirotaka Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center |
title | Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center |
title_full | Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center |
title_fullStr | Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center |
title_full_unstemmed | Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center |
title_short | Effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: Analysis of the patients treated in a Japanese center |
title_sort | effect of real‐life insulin pump with predictive low‐glucose management use for 3 months: analysis of the patients treated in a japanese center |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7610121/ https://www.ncbi.nlm.nih.gov/pubmed/32374513 http://dx.doi.org/10.1111/jdi.13288 |
work_keys_str_mv | AT tsunemiasako effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT satojunko effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT kuritamika effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT wakabayashiyuka effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT wasedanaoko effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT koshibumami effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT shinoharamai effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT ozakiatsuko effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT nakamurahiromi effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT hiranonaomi effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT ikedafuki effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT satohhiroaki effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter AT watadahirotaka effectofreallifeinsulinpumpwithpredictivelowglucosemanagementusefor3monthsanalysisofthepatientstreatedinajapanesecenter |