Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients
PURPOSE: Cardiovascular magnetic resonance first-pass perfusion for the pixel-wise detection of coronary artery disease is rapidly becoming the clinical standard, yet no widely available method exists for its assessment and validation. This study introduces a novel phantom capable of generating spat...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7611223/ https://www.ncbi.nlm.nih.gov/pubmed/32426854 http://dx.doi.org/10.1002/mrm.28296 |
_version_ | 1783605262207156224 |
---|---|
author | Milidonis, Xenios Nazir, Muhummad Sohaib Schneider, Torben Capstick, Myles Drost, Sita Kok, Gertjan Pelevic, Nikola Poelma, Christian Schaeffter, Tobias Chiribiri, Amedeo |
author_facet | Milidonis, Xenios Nazir, Muhummad Sohaib Schneider, Torben Capstick, Myles Drost, Sita Kok, Gertjan Pelevic, Nikola Poelma, Christian Schaeffter, Tobias Chiribiri, Amedeo |
author_sort | Milidonis, Xenios |
collection | PubMed |
description | PURPOSE: Cardiovascular magnetic resonance first-pass perfusion for the pixel-wise detection of coronary artery disease is rapidly becoming the clinical standard, yet no widely available method exists for its assessment and validation. This study introduces a novel phantom capable of generating spatially dependent flow values to enable assessment of new perfusion imaging methods at the pixel level. METHODS: A synthetic multicapillary myocardial phantom mimicking transmural myocardial perfusion gradients was designed and manufactured with high-precision 3D printing. The phantom was used in a stationary flow setup providing reference myocardial perfusion rates and was scanned on a 3T system. Repeated first-pass perfusion MRI for physiological perfusion rates between 1 and 4 mL/g/min was performed using a clinical dual-sequence technique. Fermi function-constrained deconvolution was used to estimate pixel-wise perfusion rate maps. Phase contrast (PC)-MRI was used to obtain velocity measurements that were converted to perfusion rates for validation of reference values and cross-method comparison. The accuracy of pixel-wise maps was assessed against simulated reference maps. RESULTS: PC-MRI indicated excellent reproducibility in perfusion rate (coefficient of variation [CoV] 2.4-3.5%) and correlation with reference values (R(2) = 0.985) across the full physiological range. Similar results were found for first-pass perfusion MRI (CoV 3.7-6.2%, R(2) = 0.987). Pixel-wise maps indicated a transmural perfusion difference of 28.8-33.7% for PC-MRI and 23.8-37.7% for first-pass perfusion, matching the reference values (30.2-31.4%). CONCLUSION: The unique transmural perfusion pattern in the phantom allows effective pixel-wise assessment of first-pass perfusion acquisition protocols and quantification algorithms before their introduction into routine clinical use. |
format | Online Article Text |
id | pubmed-7611223 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
record_format | MEDLINE/PubMed |
spelling | pubmed-76112232021-07-12 Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients Milidonis, Xenios Nazir, Muhummad Sohaib Schneider, Torben Capstick, Myles Drost, Sita Kok, Gertjan Pelevic, Nikola Poelma, Christian Schaeffter, Tobias Chiribiri, Amedeo Magn Reson Med Article PURPOSE: Cardiovascular magnetic resonance first-pass perfusion for the pixel-wise detection of coronary artery disease is rapidly becoming the clinical standard, yet no widely available method exists for its assessment and validation. This study introduces a novel phantom capable of generating spatially dependent flow values to enable assessment of new perfusion imaging methods at the pixel level. METHODS: A synthetic multicapillary myocardial phantom mimicking transmural myocardial perfusion gradients was designed and manufactured with high-precision 3D printing. The phantom was used in a stationary flow setup providing reference myocardial perfusion rates and was scanned on a 3T system. Repeated first-pass perfusion MRI for physiological perfusion rates between 1 and 4 mL/g/min was performed using a clinical dual-sequence technique. Fermi function-constrained deconvolution was used to estimate pixel-wise perfusion rate maps. Phase contrast (PC)-MRI was used to obtain velocity measurements that were converted to perfusion rates for validation of reference values and cross-method comparison. The accuracy of pixel-wise maps was assessed against simulated reference maps. RESULTS: PC-MRI indicated excellent reproducibility in perfusion rate (coefficient of variation [CoV] 2.4-3.5%) and correlation with reference values (R(2) = 0.985) across the full physiological range. Similar results were found for first-pass perfusion MRI (CoV 3.7-6.2%, R(2) = 0.987). Pixel-wise maps indicated a transmural perfusion difference of 28.8-33.7% for PC-MRI and 23.8-37.7% for first-pass perfusion, matching the reference values (30.2-31.4%). CONCLUSION: The unique transmural perfusion pattern in the phantom allows effective pixel-wise assessment of first-pass perfusion acquisition protocols and quantification algorithms before their introduction into routine clinical use. 2020-11-01 2020-05-19 /pmc/articles/PMC7611223/ /pubmed/32426854 http://dx.doi.org/10.1002/mrm.28296 Text en https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the Creative Commons Attribution (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Article Milidonis, Xenios Nazir, Muhummad Sohaib Schneider, Torben Capstick, Myles Drost, Sita Kok, Gertjan Pelevic, Nikola Poelma, Christian Schaeffter, Tobias Chiribiri, Amedeo Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients |
title | Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients |
title_full | Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients |
title_fullStr | Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients |
title_full_unstemmed | Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients |
title_short | Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients |
title_sort | pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7611223/ https://www.ncbi.nlm.nih.gov/pubmed/32426854 http://dx.doi.org/10.1002/mrm.28296 |
work_keys_str_mv | AT milidonisxenios pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT nazirmuhummadsohaib pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT schneidertorben pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT capstickmyles pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT drostsita pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT kokgertjan pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT pelevicnikola pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT poelmachristian pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT schaefftertobias pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients AT chiribiriamedeo pixelwiseassessmentofcardiovascularmagneticresonancefirstpassperfusionusingacardiacphantommimickingtransmuralmyocardialperfusiongradients |