Cargando…

Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration

Image-based computational models of the heart represent a powerful tool to shed new light on the mechanisms underlying physiological and pathological conditions in cardiac function and to improve diagnosis and therapy planning. However, in order to enable the clinical translation of such models, it...

Descripción completa

Detalles Bibliográficos
Autores principales: Marx, Laura, Niestrawska, Justyna A., Gsell, Matthias A.F., Caforio, Federica, Plank, Gernot, Augustin, Christoph M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7612790/
https://www.ncbi.nlm.nih.gov/pubmed/35662800
http://dx.doi.org/10.1016/j.jcp.2022.111266
_version_ 1783605410528231424
author Marx, Laura
Niestrawska, Justyna A.
Gsell, Matthias A.F.
Caforio, Federica
Plank, Gernot
Augustin, Christoph M.
author_facet Marx, Laura
Niestrawska, Justyna A.
Gsell, Matthias A.F.
Caforio, Federica
Plank, Gernot
Augustin, Christoph M.
author_sort Marx, Laura
collection PubMed
description Image-based computational models of the heart represent a powerful tool to shed new light on the mechanisms underlying physiological and pathological conditions in cardiac function and to improve diagnosis and therapy planning. However, in order to enable the clinical translation of such models, it is crucial to develop personalized models that are able to reproduce the physiological reality of a given patient. There have been numerous contributions in experimental and computational biomechanics to characterize the passive behavior of the myocardium. However, most of these studies suffer from severe limitations and are not applicable to high-resolution geometries. In this work, we present a novel methodology to perform an automated identification of in vivo properties of passive cardiac biomechanics. The highly-efficient algorithm fits material parameters against the shape of a patient-specific approximation of the end-diastolic pressure-volume relation (EDPVR). Simultaneously, an unloaded reference configuration is generated, where a novel line search strategy to improve convergence and robustness is implemented. Only clinical image data or previously generated meshes at one time point during diastole and one measured data point of the EDPVR are required as an input. The proposed method can be straightforwardly coupled to existing finite element (FE) software packages and is applicable to different constitutive laws and FE formulations. Sensitivity analysis demonstrates that the algorithm is robust with respect to initial input parameters.
format Online
Article
Text
id pubmed-7612790
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-76127902022-08-01 Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration Marx, Laura Niestrawska, Justyna A. Gsell, Matthias A.F. Caforio, Federica Plank, Gernot Augustin, Christoph M. J Comput Phys Article Image-based computational models of the heart represent a powerful tool to shed new light on the mechanisms underlying physiological and pathological conditions in cardiac function and to improve diagnosis and therapy planning. However, in order to enable the clinical translation of such models, it is crucial to develop personalized models that are able to reproduce the physiological reality of a given patient. There have been numerous contributions in experimental and computational biomechanics to characterize the passive behavior of the myocardium. However, most of these studies suffer from severe limitations and are not applicable to high-resolution geometries. In this work, we present a novel methodology to perform an automated identification of in vivo properties of passive cardiac biomechanics. The highly-efficient algorithm fits material parameters against the shape of a patient-specific approximation of the end-diastolic pressure-volume relation (EDPVR). Simultaneously, an unloaded reference configuration is generated, where a novel line search strategy to improve convergence and robustness is implemented. Only clinical image data or previously generated meshes at one time point during diastole and one measured data point of the EDPVR are required as an input. The proposed method can be straightforwardly coupled to existing finite element (FE) software packages and is applicable to different constitutive laws and FE formulations. Sensitivity analysis demonstrates that the algorithm is robust with respect to initial input parameters. 2022-08 /pmc/articles/PMC7612790/ /pubmed/35662800 http://dx.doi.org/10.1016/j.jcp.2022.111266 Text en https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Marx, Laura
Niestrawska, Justyna A.
Gsell, Matthias A.F.
Caforio, Federica
Plank, Gernot
Augustin, Christoph M.
Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration
title Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration
title_full Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration
title_fullStr Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration
title_full_unstemmed Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration
title_short Robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration
title_sort robust and efficient fixed-point algorithm for the inverse elastostatic problem to identify myocardial passive material parameters and the unloaded reference configuration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7612790/
https://www.ncbi.nlm.nih.gov/pubmed/35662800
http://dx.doi.org/10.1016/j.jcp.2022.111266
work_keys_str_mv AT marxlaura robustandefficientfixedpointalgorithmfortheinverseelastostaticproblemtoidentifymyocardialpassivematerialparametersandtheunloadedreferenceconfiguration
AT niestrawskajustynaa robustandefficientfixedpointalgorithmfortheinverseelastostaticproblemtoidentifymyocardialpassivematerialparametersandtheunloadedreferenceconfiguration
AT gsellmatthiasaf robustandefficientfixedpointalgorithmfortheinverseelastostaticproblemtoidentifymyocardialpassivematerialparametersandtheunloadedreferenceconfiguration
AT caforiofederica robustandefficientfixedpointalgorithmfortheinverseelastostaticproblemtoidentifymyocardialpassivematerialparametersandtheunloadedreferenceconfiguration
AT plankgernot robustandefficientfixedpointalgorithmfortheinverseelastostaticproblemtoidentifymyocardialpassivematerialparametersandtheunloadedreferenceconfiguration
AT augustinchristophm robustandefficientfixedpointalgorithmfortheinverseelastostaticproblemtoidentifymyocardialpassivematerialparametersandtheunloadedreferenceconfiguration