Cargando…

Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences

We simulated the effect of several automatic gain control (AGC) and AGC-like systems and head movement on the output levels, and resulting interaural level differences (ILDs) produced by bilateral cochlear-implant (CI) processors. The simulated AGC systems included unlinked AGCs with a range of para...

Descripción completa

Detalles Bibliográficos
Autores principales: Archer-Boyd, Alan W., Carlyon, Robert P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7613192/
https://www.ncbi.nlm.nih.gov/pubmed/34340491
http://dx.doi.org/10.1121/10.0005647
_version_ 1783605453237780480
author Archer-Boyd, Alan W.
Carlyon, Robert P.
author_facet Archer-Boyd, Alan W.
Carlyon, Robert P.
author_sort Archer-Boyd, Alan W.
collection PubMed
description We simulated the effect of several automatic gain control (AGC) and AGC-like systems and head movement on the output levels, and resulting interaural level differences (ILDs) produced by bilateral cochlear-implant (CI) processors. The simulated AGC systems included unlinked AGCs with a range of parameter settings, linked AGCs, and two proprietary multi-channel systems used in contemporary CIs. The results show that over the range of values used clinically, the parameters that most strongly affect dynamic ILDs are the release time and compression ratio. Linking AGCs preserves ILDs at the expense of monaural level changes and, possibly, comfortable listening level. Multichannel AGCs can whiten output spectra, and/or distort the dynamic changes in ILD that occur during and after head movement. We propose that an unlinked compressor with a ratio of approximately 3:1 and a release time of 300–500 ms can preserve the shape of dynamic ILDs, without causing large spectral distortions or sacrificing listening comfort.
format Online
Article
Text
id pubmed-7613192
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-76131922022-07-28 Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences Archer-Boyd, Alan W. Carlyon, Robert P. J Acoust Soc Am Article We simulated the effect of several automatic gain control (AGC) and AGC-like systems and head movement on the output levels, and resulting interaural level differences (ILDs) produced by bilateral cochlear-implant (CI) processors. The simulated AGC systems included unlinked AGCs with a range of parameter settings, linked AGCs, and two proprietary multi-channel systems used in contemporary CIs. The results show that over the range of values used clinically, the parameters that most strongly affect dynamic ILDs are the release time and compression ratio. Linking AGCs preserves ILDs at the expense of monaural level changes and, possibly, comfortable listening level. Multichannel AGCs can whiten output spectra, and/or distort the dynamic changes in ILD that occur during and after head movement. We propose that an unlinked compressor with a ratio of approximately 3:1 and a release time of 300–500 ms can preserve the shape of dynamic ILDs, without causing large spectral distortions or sacrificing listening comfort. 2021-07-01 /pmc/articles/PMC7613192/ /pubmed/34340491 http://dx.doi.org/10.1121/10.0005647 Text en https://creativecommons.org/licenses/by/4.0/All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Archer-Boyd, Alan W.
Carlyon, Robert P.
Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences
title Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences
title_full Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences
title_fullStr Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences
title_full_unstemmed Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences
title_short Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences
title_sort further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7613192/
https://www.ncbi.nlm.nih.gov/pubmed/34340491
http://dx.doi.org/10.1121/10.0005647
work_keys_str_mv AT archerboydalanw furthersimulationsoftheeffectofcochlearimplantpreprocessingandheadmovementoninterauralleveldifferences
AT carlyonrobertp furthersimulationsoftheeffectofcochlearimplantpreprocessingandheadmovementoninterauralleveldifferences