Cargando…

Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route

AIM: Coronary interventions are increasingly being performed via the radial rather than femoral route because of the lower complication rate. Compression devices such as the TR band are used to achieve hemostasis after the procedure. At present, there are no clear protocols for the deflation of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Riyami, Hassan Al, Riyami, Adil Al, Nadar, Sunil K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Saudi Heart Association 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7640594/
https://www.ncbi.nlm.nih.gov/pubmed/33154892
http://dx.doi.org/10.37616/2212-5043.1009
_version_ 1783605779324993536
author Riyami, Hassan Al
Riyami, Adil Al
Nadar, Sunil K.
author_facet Riyami, Hassan Al
Riyami, Adil Al
Nadar, Sunil K.
author_sort Riyami, Hassan Al
collection PubMed
description AIM: Coronary interventions are increasingly being performed via the radial rather than femoral route because of the lower complication rate. Compression devices such as the TR band are used to achieve hemostasis after the procedure. At present, there are no clear protocols for the deflation of the band. In this study we compared two protocols (early deflation with increased intervals vs. late deflation with smaller intervals) in terms of total time to band removal and complications, and patient and staff satisfaction. METHODS: All patients who underwent a transradial coronary procedure and had a TR band fitted were enrolled into the study. The TR band was applied using the patent hemostasis method (2 ml air pushed in after the radial pulse appears on pulse oximetry after full occlusion with 16 ml air). Patients were randomly assigned to either protocol. Protocol 1 involved removal of 2 ml of air starting 1 hour after the sheath removal and then removal of 2 ml every 30 minutes until the band came off. Protocol 2 involved removal of 4 ml of air 2 hours after the sheath removal and then further 4 ml of air every 15 minutes until the band came off. Patient and staff satisfaction was measured with a visual analogue scale. RESULTS: A total of 174 patients were recruited (mean age, 60 ± 11 years; 127 male, 47 female). The baseline characteristics including total heparin dose and type of procedure, in the two arms were the same. Protocol 2 (n = 84) was associated with a significantly lower time to TR band removal as compared to protocol 1 (n = 90; 201 ± 43 min vs. 274 ± 54 min; p < 0.001). There was no difference in complications such as bleeding or hematoma formation between the two groups. Patient satisfaction was the same between the two groups. However, the staff preferred protocol 1 (p = 0.01). CONCLUSION: A protocol of delayed initiation of TR band deflation followed by quick deflations is associated with a lower time to band removal with no increase in bleeding complications or patient satisfaction. However, the staff preferred longer intervals between deflations.
format Online
Article
Text
id pubmed-7640594
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Saudi Heart Association
record_format MEDLINE/PubMed
spelling pubmed-76405942020-11-04 Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route Riyami, Hassan Al Riyami, Adil Al Nadar, Sunil K. J Saudi Heart Assoc Original Article AIM: Coronary interventions are increasingly being performed via the radial rather than femoral route because of the lower complication rate. Compression devices such as the TR band are used to achieve hemostasis after the procedure. At present, there are no clear protocols for the deflation of the band. In this study we compared two protocols (early deflation with increased intervals vs. late deflation with smaller intervals) in terms of total time to band removal and complications, and patient and staff satisfaction. METHODS: All patients who underwent a transradial coronary procedure and had a TR band fitted were enrolled into the study. The TR band was applied using the patent hemostasis method (2 ml air pushed in after the radial pulse appears on pulse oximetry after full occlusion with 16 ml air). Patients were randomly assigned to either protocol. Protocol 1 involved removal of 2 ml of air starting 1 hour after the sheath removal and then removal of 2 ml every 30 minutes until the band came off. Protocol 2 involved removal of 4 ml of air 2 hours after the sheath removal and then further 4 ml of air every 15 minutes until the band came off. Patient and staff satisfaction was measured with a visual analogue scale. RESULTS: A total of 174 patients were recruited (mean age, 60 ± 11 years; 127 male, 47 female). The baseline characteristics including total heparin dose and type of procedure, in the two arms were the same. Protocol 2 (n = 84) was associated with a significantly lower time to TR band removal as compared to protocol 1 (n = 90; 201 ± 43 min vs. 274 ± 54 min; p < 0.001). There was no difference in complications such as bleeding or hematoma formation between the two groups. Patient satisfaction was the same between the two groups. However, the staff preferred protocol 1 (p = 0.01). CONCLUSION: A protocol of delayed initiation of TR band deflation followed by quick deflations is associated with a lower time to band removal with no increase in bleeding complications or patient satisfaction. However, the staff preferred longer intervals between deflations. Saudi Heart Association 2020-04-17 /pmc/articles/PMC7640594/ /pubmed/33154892 http://dx.doi.org/10.37616/2212-5043.1009 Text en © 2020 Saudi Heart Association This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Riyami, Hassan Al
Riyami, Adil Al
Nadar, Sunil K.
Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route
title Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route
title_full Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route
title_fullStr Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route
title_full_unstemmed Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route
title_short Comparison between two protocols for deflation of the TR band following coronary procedures via the radial route
title_sort comparison between two protocols for deflation of the tr band following coronary procedures via the radial route
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7640594/
https://www.ncbi.nlm.nih.gov/pubmed/33154892
http://dx.doi.org/10.37616/2212-5043.1009
work_keys_str_mv AT riyamihassanal comparisonbetweentwoprotocolsfordeflationofthetrbandfollowingcoronaryproceduresviatheradialroute
AT riyamiadilal comparisonbetweentwoprotocolsfordeflationofthetrbandfollowingcoronaryproceduresviatheradialroute
AT nadarsunilk comparisonbetweentwoprotocolsfordeflationofthetrbandfollowingcoronaryproceduresviatheradialroute