Cargando…
A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor
The Montgomery T-tube is widely used to stent airway stenotic diseases. Conventional insertion methods can sometimes fail in the case of long-distance subglottic stenosis due to the flexibility of a T-tube made of silicon, which kinks when forced against resistance. Therefore, an alternative approac...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7641885/ https://www.ncbi.nlm.nih.gov/pubmed/32741884 http://dx.doi.org/10.5761/atcs.nm.20-00128 |
_version_ | 1783606016027394048 |
---|---|
author | Kato, Tatsuya Fujiwara-Kuroda, Aki Shiina, Nobuyuki Aragaki, Masato Ujiie, Hideki Hida, Yasuhiro Kaga, Kichizo |
author_facet | Kato, Tatsuya Fujiwara-Kuroda, Aki Shiina, Nobuyuki Aragaki, Masato Ujiie, Hideki Hida, Yasuhiro Kaga, Kichizo |
author_sort | Kato, Tatsuya |
collection | PubMed |
description | The Montgomery T-tube is widely used to stent airway stenotic diseases. Conventional insertion methods can sometimes fail in the case of long-distance subglottic stenosis due to the flexibility of a T-tube made of silicon, which kinks when forced against resistance. Therefore, an alternative approach can assist in the insertion of an extra-long T-tube, especially when using a long proximal limb. We report herein the case of a patient with a large mediastinal tumor caused by neurofibromatosis type 1 in which airway obstruction was avoided through the use of a novel extra-long T-tube placement technique. |
format | Online Article Text |
id | pubmed-7641885 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-76418852021-01-08 A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor Kato, Tatsuya Fujiwara-Kuroda, Aki Shiina, Nobuyuki Aragaki, Masato Ujiie, Hideki Hida, Yasuhiro Kaga, Kichizo Ann Thorac Cardiovasc Surg New Method The Montgomery T-tube is widely used to stent airway stenotic diseases. Conventional insertion methods can sometimes fail in the case of long-distance subglottic stenosis due to the flexibility of a T-tube made of silicon, which kinks when forced against resistance. Therefore, an alternative approach can assist in the insertion of an extra-long T-tube, especially when using a long proximal limb. We report herein the case of a patient with a large mediastinal tumor caused by neurofibromatosis type 1 in which airway obstruction was avoided through the use of a novel extra-long T-tube placement technique. The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2020-08-01 2020 /pmc/articles/PMC7641885/ /pubmed/32741884 http://dx.doi.org/10.5761/atcs.nm.20-00128 Text en ©2020 Annals of Thoracic and Cardiovascular Surgery http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NonDerivatives International License (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | New Method Kato, Tatsuya Fujiwara-Kuroda, Aki Shiina, Nobuyuki Aragaki, Masato Ujiie, Hideki Hida, Yasuhiro Kaga, Kichizo A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor |
title | A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor |
title_full | A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor |
title_fullStr | A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor |
title_full_unstemmed | A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor |
title_short | A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor |
title_sort | novel insertion technique for the extra-long montgomery t-tube in patients with a large mediastinal tumor |
topic | New Method |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7641885/ https://www.ncbi.nlm.nih.gov/pubmed/32741884 http://dx.doi.org/10.5761/atcs.nm.20-00128 |
work_keys_str_mv | AT katotatsuya anovelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT fujiwarakurodaaki anovelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT shiinanobuyuki anovelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT aragakimasato anovelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT ujiiehideki anovelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT hidayasuhiro anovelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT kagakichizo anovelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT katotatsuya novelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT fujiwarakurodaaki novelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT shiinanobuyuki novelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT aragakimasato novelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT ujiiehideki novelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT hidayasuhiro novelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor AT kagakichizo novelinsertiontechniquefortheextralongmontgomeryttubeinpatientswithalargemediastinaltumor |