Cargando…

Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model

OBJECTIVES: The COVID-19 pandemic and the disproportional spread of the disease among otorhinolaryngologists raised concerns regarding the safety of health care staff. Therefore, a quantitative risk assessment for otologic surgery would be desirable. This study aims to quantitatively compare the ris...

Descripción completa

Detalles Bibliográficos
Autores principales: Anschuetz, Lukas, Yacoub, Abraam, Buetzer, Tobias, Fernandez, Ignacio J., Wimmer, Wilhelm, Caversaccio, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7642824/
https://www.ncbi.nlm.nih.gov/pubmed/33138717
http://dx.doi.org/10.1177/0194599820970506
_version_ 1783606159559622656
author Anschuetz, Lukas
Yacoub, Abraam
Buetzer, Tobias
Fernandez, Ignacio J.
Wimmer, Wilhelm
Caversaccio, Marco
author_facet Anschuetz, Lukas
Yacoub, Abraam
Buetzer, Tobias
Fernandez, Ignacio J.
Wimmer, Wilhelm
Caversaccio, Marco
author_sort Anschuetz, Lukas
collection PubMed
description OBJECTIVES: The COVID-19 pandemic and the disproportional spread of the disease among otorhinolaryngologists raised concerns regarding the safety of health care staff. Therefore, a quantitative risk assessment for otologic surgery would be desirable. This study aims to quantitatively compare the risk of perioperative droplet formation between microscopic and endoscopic approaches. STUDY DESIGN: Experimental research. SETTING: Temporal bone laboratory. METHODS: The middle ear of whole head specimens was injected with fluorescein (0.2 mg/10 mL) before endoscopic and microscopic epitympanectomy and mastoidectomy. Fluorescent droplet deposition on the surgical table was recorded under ultraviolet light, quantified, and compared among the interventions. Drilling time, droplet proportion, fluorescein intensity, and droplet size were assessed for every procedure. RESULTS: A total of 12 procedures were performed: 4 endoscopic epitympanectomies, 4 microscopic epitympanectomies, and 4 mastoidectomies. The mean (SD) proportion of fluorescein droplets was 0.14‰ (0.10‰) for endoscopic epitympanectomy and 0.64‰ (0.31‰) for microscopic epitympanectomy. During mastoidectomy, the deposition of droplets was 8.77‰ (6.71‰). Statistical comparison based on a mixed effects model revealed a significant increase (0.50‰) in droplet deposition during microscopic epitympanectomy as compared with endoscopic epitympanectomy (95% CI, 0.16‰ to 0.84‰). CONCLUSIONS: There is considerable droplet generation during otologic surgery, and this represents a risk for the spread of airborne infectious diseases. The endoscopic technique offers the lowest risk of droplet formation as compared with microscopic approaches, with a significant 4.5-fold reduction of droplets between endoscopic and microscopic epitympanectomy and a 62-fold reduction between endoscopic epitympanectomy and cortical mastoidectomy.
format Online
Article
Text
id pubmed-7642824
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-76428242020-11-05 Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model Anschuetz, Lukas Yacoub, Abraam Buetzer, Tobias Fernandez, Ignacio J. Wimmer, Wilhelm Caversaccio, Marco Otolaryngol Head Neck Surg General Otolaryngology OBJECTIVES: The COVID-19 pandemic and the disproportional spread of the disease among otorhinolaryngologists raised concerns regarding the safety of health care staff. Therefore, a quantitative risk assessment for otologic surgery would be desirable. This study aims to quantitatively compare the risk of perioperative droplet formation between microscopic and endoscopic approaches. STUDY DESIGN: Experimental research. SETTING: Temporal bone laboratory. METHODS: The middle ear of whole head specimens was injected with fluorescein (0.2 mg/10 mL) before endoscopic and microscopic epitympanectomy and mastoidectomy. Fluorescent droplet deposition on the surgical table was recorded under ultraviolet light, quantified, and compared among the interventions. Drilling time, droplet proportion, fluorescein intensity, and droplet size were assessed for every procedure. RESULTS: A total of 12 procedures were performed: 4 endoscopic epitympanectomies, 4 microscopic epitympanectomies, and 4 mastoidectomies. The mean (SD) proportion of fluorescein droplets was 0.14‰ (0.10‰) for endoscopic epitympanectomy and 0.64‰ (0.31‰) for microscopic epitympanectomy. During mastoidectomy, the deposition of droplets was 8.77‰ (6.71‰). Statistical comparison based on a mixed effects model revealed a significant increase (0.50‰) in droplet deposition during microscopic epitympanectomy as compared with endoscopic epitympanectomy (95% CI, 0.16‰ to 0.84‰). CONCLUSIONS: There is considerable droplet generation during otologic surgery, and this represents a risk for the spread of airborne infectious diseases. The endoscopic technique offers the lowest risk of droplet formation as compared with microscopic approaches, with a significant 4.5-fold reduction of droplets between endoscopic and microscopic epitympanectomy and a 62-fold reduction between endoscopic epitympanectomy and cortical mastoidectomy. SAGE Publications 2020-11-03 2021-06 /pmc/articles/PMC7642824/ /pubmed/33138717 http://dx.doi.org/10.1177/0194599820970506 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle General Otolaryngology
Anschuetz, Lukas
Yacoub, Abraam
Buetzer, Tobias
Fernandez, Ignacio J.
Wimmer, Wilhelm
Caversaccio, Marco
Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model
title Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model
title_full Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model
title_fullStr Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model
title_full_unstemmed Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model
title_short Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model
title_sort quantification and comparison of droplet formation during endoscopic and microscopic ear surgery: a cadaveric model
topic General Otolaryngology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7642824/
https://www.ncbi.nlm.nih.gov/pubmed/33138717
http://dx.doi.org/10.1177/0194599820970506
work_keys_str_mv AT anschuetzlukas quantificationandcomparisonofdropletformationduringendoscopicandmicroscopicearsurgeryacadavericmodel
AT yacoubabraam quantificationandcomparisonofdropletformationduringendoscopicandmicroscopicearsurgeryacadavericmodel
AT buetzertobias quantificationandcomparisonofdropletformationduringendoscopicandmicroscopicearsurgeryacadavericmodel
AT fernandezignacioj quantificationandcomparisonofdropletformationduringendoscopicandmicroscopicearsurgeryacadavericmodel
AT wimmerwilhelm quantificationandcomparisonofdropletformationduringendoscopicandmicroscopicearsurgeryacadavericmodel
AT caversacciomarco quantificationandcomparisonofdropletformationduringendoscopicandmicroscopicearsurgeryacadavericmodel