Cargando…
Study on the Flammability Limits of Lithium-Ion Battery Vent Gas under Different Initial Conditions
[Image: see text] In this paper, the flammability limit of the battery thermal runaway vent gas (BVG) is studied numerically by using the CHEMKIN 2.0 code. The research content mainly includes the change of flammability limit with the state of charge, initial temperature, and initial pressure. The c...
Autores principales: | Ma, Biao, Liu, Jie, Yu, Ruiguang |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7643196/ https://www.ncbi.nlm.nih.gov/pubmed/33163792 http://dx.doi.org/10.1021/acsomega.0c03713 |