Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials

A quick, flexible and reliable method was developed, based on laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), for accurate assessment of nanomaterial composition with sample amounts in the picogram to nanogram range. We demonstrate its capabilities for the analysis of surfac...

Descripción completa

Detalles Bibliográficos
Autores principales: Horak, Felix, Nagl, Andreas, Föttinger, Karin, Limbeck, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7644544/
https://www.ncbi.nlm.nih.gov/pubmed/33155061
http://dx.doi.org/10.1007/s00604-020-04609-9
_version_ 1783606480342089728
author Horak, Felix
Nagl, Andreas
Föttinger, Karin
Limbeck, Andreas
author_facet Horak, Felix
Nagl, Andreas
Föttinger, Karin
Limbeck, Andreas
author_sort Horak, Felix
collection PubMed
description A quick, flexible and reliable method was developed, based on laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), for accurate assessment of nanomaterial composition with sample amounts in the picogram to nanogram range. We demonstrate its capabilities for the analysis of surface-modified TiO(2) nanoparticulate (NP) catalyst materials. For sampling, suspensions of NP were deposited on a substrate material, ablated with a pulsed laser and then analysed using quadrupole ICP-MS. The calibration and quantification approach is based on the use of so-called micro-dried droplets (μDD) as the standard material. To overcome some of the major drawbacks of conventional dried droplet approaches, self-aliquoting wells were used in this work. By mimicking the ablation conditions for the sample and standard, it was possible to create a pseudo-matrix-matched calibration, not only for this specific NP composition but also for a larger variety of samples. A commercially available reference material (AUROlite™, Strem Chemicals) was used to compare the method against established methods such as slurry analysis and microwave-assisted digestion in combination with subsequent liquid sample measurement. The results obtained with the proposed procedure (0.74%wt ± 0.13%wt) are in good agreement to a certified value (0.8%wt) and added an additional layer of information. Due to the significantly reduced sampling size in comparison with the investigated liquid measurement approaches, it was possible to obtain information about the homogeneity of the catalyst material. The results indicate that the AUROlite™ reference material has a heterogeneous loading which requires more than 300 pg of material to be used to cancel out. This was not observed for the custom materials discussed in this work. [Figure: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-020-04609-9.
format Online
Article
Text
id pubmed-7644544
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-76445442020-11-10 Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials Horak, Felix Nagl, Andreas Föttinger, Karin Limbeck, Andreas Mikrochim Acta Original Paper A quick, flexible and reliable method was developed, based on laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), for accurate assessment of nanomaterial composition with sample amounts in the picogram to nanogram range. We demonstrate its capabilities for the analysis of surface-modified TiO(2) nanoparticulate (NP) catalyst materials. For sampling, suspensions of NP were deposited on a substrate material, ablated with a pulsed laser and then analysed using quadrupole ICP-MS. The calibration and quantification approach is based on the use of so-called micro-dried droplets (μDD) as the standard material. To overcome some of the major drawbacks of conventional dried droplet approaches, self-aliquoting wells were used in this work. By mimicking the ablation conditions for the sample and standard, it was possible to create a pseudo-matrix-matched calibration, not only for this specific NP composition but also for a larger variety of samples. A commercially available reference material (AUROlite™, Strem Chemicals) was used to compare the method against established methods such as slurry analysis and microwave-assisted digestion in combination with subsequent liquid sample measurement. The results obtained with the proposed procedure (0.74%wt ± 0.13%wt) are in good agreement to a certified value (0.8%wt) and added an additional layer of information. Due to the significantly reduced sampling size in comparison with the investigated liquid measurement approaches, it was possible to obtain information about the homogeneity of the catalyst material. The results indicate that the AUROlite™ reference material has a heterogeneous loading which requires more than 300 pg of material to be used to cancel out. This was not observed for the custom materials discussed in this work. [Figure: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-020-04609-9. Springer Vienna 2020-11-05 2020 /pmc/articles/PMC7644544/ /pubmed/33155061 http://dx.doi.org/10.1007/s00604-020-04609-9 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Paper
Horak, Felix
Nagl, Andreas
Föttinger, Karin
Limbeck, Andreas
Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials
title Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials
title_full Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials
title_fullStr Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials
title_full_unstemmed Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials
title_short Application of micro-dried droplets for quantitative analysis of particulate inorganic samples with LA-ICP-MS demonstrated on surface-modified nanoparticle TiO(2) catalyst materials
title_sort application of micro-dried droplets for quantitative analysis of particulate inorganic samples with la-icp-ms demonstrated on surface-modified nanoparticle tio(2) catalyst materials
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7644544/
https://www.ncbi.nlm.nih.gov/pubmed/33155061
http://dx.doi.org/10.1007/s00604-020-04609-9
work_keys_str_mv AT horakfelix applicationofmicrodrieddropletsforquantitativeanalysisofparticulateinorganicsampleswithlaicpmsdemonstratedonsurfacemodifiednanoparticletio2catalystmaterials
AT naglandreas applicationofmicrodrieddropletsforquantitativeanalysisofparticulateinorganicsampleswithlaicpmsdemonstratedonsurfacemodifiednanoparticletio2catalystmaterials
AT fottingerkarin applicationofmicrodrieddropletsforquantitativeanalysisofparticulateinorganicsampleswithlaicpmsdemonstratedonsurfacemodifiednanoparticletio2catalystmaterials
AT limbeckandreas applicationofmicrodrieddropletsforquantitativeanalysisofparticulateinorganicsampleswithlaicpmsdemonstratedonsurfacemodifiednanoparticletio2catalystmaterials