Cargando…

Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users

The effect of the relative timing between pairs of same-polarity monophasic pulses has been studied extensively in single-neuron animal studies and has revealed fundamental properties of the neurons. For human cochlear implant listeners, the requirement to use charge-balanced stimulation and the typ...

Descripción completa

Detalles Bibliográficos
Autores principales: Guérit, François, Marozeau, Jeremy, Epp, Bastian, Carlyon, Robert P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7644659/
https://www.ncbi.nlm.nih.gov/pubmed/32833160
http://dx.doi.org/10.1007/s10162-020-00767-y
_version_ 1783606499132571648
author Guérit, François
Marozeau, Jeremy
Epp, Bastian
Carlyon, Robert P.
author_facet Guérit, François
Marozeau, Jeremy
Epp, Bastian
Carlyon, Robert P.
author_sort Guérit, François
collection PubMed
description The effect of the relative timing between pairs of same-polarity monophasic pulses has been studied extensively in single-neuron animal studies and has revealed fundamental properties of the neurons. For human cochlear implant listeners, the requirement to use charge-balanced stimulation and the typical use of symmetric, biphasic pulses limits such measures, because currents of opposite polarities interact at the level of the neural membrane. Here, we propose a paradigm to study same-polarity summation of currents while keeping the stimulation charge-balanced within a short time window. We used pairs of mirrored pseudo-monophasic pulses (a long-low phase followed by a short-high phase for the first pulse and a short-high phase followed by a long-low phase for the second pulse). We assumed that most of the excitation would stem from the two adjacent short-high phases, which had the same polarity. The inter-pulse interval between the short-high phases was varied from 0 to 345 μs. The inter-pulse interval had a significant effect on the perceived loudness, and this effect was consistent with both passive (membrane-related) and active (ion-channel-related) neuronal mechanisms contributing to facilitation. Furthermore, the effect of interval interacted with the polarity of the pulse pairs. At threshold, there was an effect of polarity, but, surprisingly, no effect of interval nor an interaction between the two factors. We discuss possible peripheral origins of these results.
format Online
Article
Text
id pubmed-7644659
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-76446592020-11-10 Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users Guérit, François Marozeau, Jeremy Epp, Bastian Carlyon, Robert P. J Assoc Res Otolaryngol Research Article The effect of the relative timing between pairs of same-polarity monophasic pulses has been studied extensively in single-neuron animal studies and has revealed fundamental properties of the neurons. For human cochlear implant listeners, the requirement to use charge-balanced stimulation and the typical use of symmetric, biphasic pulses limits such measures, because currents of opposite polarities interact at the level of the neural membrane. Here, we propose a paradigm to study same-polarity summation of currents while keeping the stimulation charge-balanced within a short time window. We used pairs of mirrored pseudo-monophasic pulses (a long-low phase followed by a short-high phase for the first pulse and a short-high phase followed by a long-low phase for the second pulse). We assumed that most of the excitation would stem from the two adjacent short-high phases, which had the same polarity. The inter-pulse interval between the short-high phases was varied from 0 to 345 μs. The inter-pulse interval had a significant effect on the perceived loudness, and this effect was consistent with both passive (membrane-related) and active (ion-channel-related) neuronal mechanisms contributing to facilitation. Furthermore, the effect of interval interacted with the polarity of the pulse pairs. At threshold, there was an effect of polarity, but, surprisingly, no effect of interval nor an interaction between the two factors. We discuss possible peripheral origins of these results. Springer US 2020-08-24 2020-12 /pmc/articles/PMC7644659/ /pubmed/32833160 http://dx.doi.org/10.1007/s10162-020-00767-y Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Research Article
Guérit, François
Marozeau, Jeremy
Epp, Bastian
Carlyon, Robert P.
Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users
title Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users
title_full Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users
title_fullStr Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users
title_full_unstemmed Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users
title_short Effect of the Relative Timing between Same-Polarity Pulses on Thresholds and Loudness in Cochlear Implant Users
title_sort effect of the relative timing between same-polarity pulses on thresholds and loudness in cochlear implant users
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7644659/
https://www.ncbi.nlm.nih.gov/pubmed/32833160
http://dx.doi.org/10.1007/s10162-020-00767-y
work_keys_str_mv AT gueritfrancois effectoftherelativetimingbetweensamepolaritypulsesonthresholdsandloudnessincochlearimplantusers
AT marozeaujeremy effectoftherelativetimingbetweensamepolaritypulsesonthresholdsandloudnessincochlearimplantusers
AT eppbastian effectoftherelativetimingbetweensamepolaritypulsesonthresholdsandloudnessincochlearimplantusers
AT carlyonrobertp effectoftherelativetimingbetweensamepolaritypulsesonthresholdsandloudnessincochlearimplantusers