Cargando…

Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound

BACKGROUND: Simulators are an extensively utilized teaching tool in clinical settings. Simulation enables learners to practice and improve their skills in a safe and controlled environment before using these skills on patients. We evaluated the effect of a training session utilizing a novel intubati...

Descripción completa

Detalles Bibliográficos
Autores principales: Ali, Khushboo Qaim, Soofi, Sajid Bashir, Hussain, Ali Shabbir, Ansari, Uzair, Morris, Shaun, Tessaro, Mark Oliver, Ariff, Shabina, Merali, Hasan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7648944/
https://www.ncbi.nlm.nih.gov/pubmed/33160342
http://dx.doi.org/10.1186/s12909-020-02338-4
_version_ 1783607215598338048
author Ali, Khushboo Qaim
Soofi, Sajid Bashir
Hussain, Ali Shabbir
Ansari, Uzair
Morris, Shaun
Tessaro, Mark Oliver
Ariff, Shabina
Merali, Hasan
author_facet Ali, Khushboo Qaim
Soofi, Sajid Bashir
Hussain, Ali Shabbir
Ansari, Uzair
Morris, Shaun
Tessaro, Mark Oliver
Ariff, Shabina
Merali, Hasan
author_sort Ali, Khushboo Qaim
collection PubMed
description BACKGROUND: Simulators are an extensively utilized teaching tool in clinical settings. Simulation enables learners to practice and improve their skills in a safe and controlled environment before using these skills on patients. We evaluated the effect of a training session utilizing a novel intubation ultrasound simulator on the accuracy of provider detection of tracheal versus esophageal neonatal endotracheal tube (ETT) placement using point-of-care ultrasound (POCUS). We also investigated whether the time to POCUS image interpretation decreased with repeated simulator attempts. METHODS: Sixty neonatal health care providers participated in a three-hour simulator-based training session in the neonatal intensive care unit (NICU) of Aga Khan University Hospital (AKUH), Karachi, Pakistan. Participants included neonatologists, neonatal fellows, pediatric residents and senior nursing staff. The training utilized a novel low-cost simulator made with gelatin, water and psyllium fiber. Training consisted of a didactic session, practice with the simulator, and practice with intubated NICU patients. At the end of training, participants underwent an objective structured assessment of technical skills (OSATS) and ten rounds of simulator-based testing of their ability to use POCUS to differentiate between simulated tracheal and esophageal intubations. RESULTS: The majority of the participants in the training had an average of 7.0 years (SD 4.9) of clinical experience. After controlling for gender, profession, years of practice and POCUS knowledge, linear mixed model and mixed effects logistic regression demonstrated marginal improvement in POCUS interpretation over repeated simulator testing. The mean time-to-interpretation decreased from 24.7 (SD 20.3) seconds for test 1 to 10.1 (SD 4.5) seconds for Test 10, p < 0.001. There was an average reduction of 1.3 s (β = − 1.3; 95% CI: − 1.66 to − 1.0) in time-to-interpretation with repeated simulator testing after adjusting for the covariates listed above. CONCLUSION: We found a three-hour simulator-based training session had a significant impact on technical skills and performance of neonatal health care providers in identification of ETT position using POCUS. Further research is needed to examine whether these skills are transferable to intubated newborns in various health settings. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03533218. Registered May 2018.
format Online
Article
Text
id pubmed-7648944
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-76489442020-11-09 Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound Ali, Khushboo Qaim Soofi, Sajid Bashir Hussain, Ali Shabbir Ansari, Uzair Morris, Shaun Tessaro, Mark Oliver Ariff, Shabina Merali, Hasan BMC Med Educ Research Article BACKGROUND: Simulators are an extensively utilized teaching tool in clinical settings. Simulation enables learners to practice and improve their skills in a safe and controlled environment before using these skills on patients. We evaluated the effect of a training session utilizing a novel intubation ultrasound simulator on the accuracy of provider detection of tracheal versus esophageal neonatal endotracheal tube (ETT) placement using point-of-care ultrasound (POCUS). We also investigated whether the time to POCUS image interpretation decreased with repeated simulator attempts. METHODS: Sixty neonatal health care providers participated in a three-hour simulator-based training session in the neonatal intensive care unit (NICU) of Aga Khan University Hospital (AKUH), Karachi, Pakistan. Participants included neonatologists, neonatal fellows, pediatric residents and senior nursing staff. The training utilized a novel low-cost simulator made with gelatin, water and psyllium fiber. Training consisted of a didactic session, practice with the simulator, and practice with intubated NICU patients. At the end of training, participants underwent an objective structured assessment of technical skills (OSATS) and ten rounds of simulator-based testing of their ability to use POCUS to differentiate between simulated tracheal and esophageal intubations. RESULTS: The majority of the participants in the training had an average of 7.0 years (SD 4.9) of clinical experience. After controlling for gender, profession, years of practice and POCUS knowledge, linear mixed model and mixed effects logistic regression demonstrated marginal improvement in POCUS interpretation over repeated simulator testing. The mean time-to-interpretation decreased from 24.7 (SD 20.3) seconds for test 1 to 10.1 (SD 4.5) seconds for Test 10, p < 0.001. There was an average reduction of 1.3 s (β = − 1.3; 95% CI: − 1.66 to − 1.0) in time-to-interpretation with repeated simulator testing after adjusting for the covariates listed above. CONCLUSION: We found a three-hour simulator-based training session had a significant impact on technical skills and performance of neonatal health care providers in identification of ETT position using POCUS. Further research is needed to examine whether these skills are transferable to intubated newborns in various health settings. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03533218. Registered May 2018. BioMed Central 2020-11-07 /pmc/articles/PMC7648944/ /pubmed/33160342 http://dx.doi.org/10.1186/s12909-020-02338-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Ali, Khushboo Qaim
Soofi, Sajid Bashir
Hussain, Ali Shabbir
Ansari, Uzair
Morris, Shaun
Tessaro, Mark Oliver
Ariff, Shabina
Merali, Hasan
Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound
title Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound
title_full Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound
title_fullStr Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound
title_full_unstemmed Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound
title_short Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound
title_sort simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7648944/
https://www.ncbi.nlm.nih.gov/pubmed/33160342
http://dx.doi.org/10.1186/s12909-020-02338-4
work_keys_str_mv AT alikhushbooqaim simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound
AT soofisajidbashir simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound
AT hussainalishabbir simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound
AT ansariuzair simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound
AT morrisshaun simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound
AT tessaromarkoliver simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound
AT ariffshabina simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound
AT meralihasan simulatorbasedultrasoundtrainingforidentificationofendotrachealtubeplacementinaneonatalintensivecareunitusingpointofcareultrasound