Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique

Revision of a failed acetabular component in the presence of an intact femoral prosthesis comprises approximately 20% of revision total hip replacements performed by the senior author. During this procedure, the femoral trunnion is at risk of damage because of scratching from retractors, reamers, or...

Descripción completa

Detalles Bibliográficos
Autores principales: Kawalkar, Abhijit C., Vertzyas, Nick, Neil, Michael J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7649106/
https://www.ncbi.nlm.nih.gov/pubmed/33204787
http://dx.doi.org/10.1016/j.artd.2020.09.015
_version_ 1783607251617972224
author Kawalkar, Abhijit C.
Vertzyas, Nick
Neil, Michael J.
author_facet Kawalkar, Abhijit C.
Vertzyas, Nick
Neil, Michael J.
author_sort Kawalkar, Abhijit C.
collection PubMed
description Revision of a failed acetabular component in the presence of an intact femoral prosthesis comprises approximately 20% of revision total hip replacements performed by the senior author. During this procedure, the femoral trunnion is at risk of damage because of scratching from retractors, reamers, or other instruments. Scratching can result in mechanically assisted crevice corrosion or adverse local-tissue reaction or trunnionosis leading to implant failure. We have used a variety of techniques for protection of the femoral taper over the last 30 years. We describe our current method of taper protection, using a cut segment of #5 silicon laryngeal airway, which is a simple and effective method.
format Online
Article
Text
id pubmed-7649106
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-76491062020-11-16 Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique Kawalkar, Abhijit C. Vertzyas, Nick Neil, Michael J. Arthroplast Today Surgical Technique Revision of a failed acetabular component in the presence of an intact femoral prosthesis comprises approximately 20% of revision total hip replacements performed by the senior author. During this procedure, the femoral trunnion is at risk of damage because of scratching from retractors, reamers, or other instruments. Scratching can result in mechanically assisted crevice corrosion or adverse local-tissue reaction or trunnionosis leading to implant failure. We have used a variety of techniques for protection of the femoral taper over the last 30 years. We describe our current method of taper protection, using a cut segment of #5 silicon laryngeal airway, which is a simple and effective method. Elsevier 2020-11-04 /pmc/articles/PMC7649106/ /pubmed/33204787 http://dx.doi.org/10.1016/j.artd.2020.09.015 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Surgical Technique
Kawalkar, Abhijit C.
Vertzyas, Nick
Neil, Michael J.
Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique
title Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique
title_full Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique
title_fullStr Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique
title_full_unstemmed Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique
title_short Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery—A Novel Technique
title_sort protection of the femoral trunnion during acetabular revision hip surgery—a novel technique
topic Surgical Technique
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7649106/
https://www.ncbi.nlm.nih.gov/pubmed/33204787
http://dx.doi.org/10.1016/j.artd.2020.09.015
work_keys_str_mv AT kawalkarabhijitc protectionofthefemoraltrunnionduringacetabularrevisionhipsurgeryanoveltechnique
AT vertzyasnick protectionofthefemoraltrunnionduringacetabularrevisionhipsurgeryanoveltechnique
AT neilmichaelj protectionofthefemoraltrunnionduringacetabularrevisionhipsurgeryanoveltechnique