Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report

BACKGROUND: The risk of coronary obstruction during transcatheter aortic valve-in-valve replacement (VIV-TAVR) in patients deemed at high risk for surgical re-intervention is still a concerning issue. CASE SUMMARY: A 78-year-old woman with a past medical history of hypertension, chronic kidney disea...

Descripción completa

Detalles Bibliográficos
Autores principales: Marchese, Alfredo, Tarantini, Giuseppe, Tito, Antonio, Colombo, Antonio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7649518/
https://www.ncbi.nlm.nih.gov/pubmed/33204994
http://dx.doi.org/10.1093/ehjcr/ytaa368
_version_ 1783607346074746880
author Marchese, Alfredo
Tarantini, Giuseppe
Tito, Antonio
Colombo, Antonio
author_facet Marchese, Alfredo
Tarantini, Giuseppe
Tito, Antonio
Colombo, Antonio
author_sort Marchese, Alfredo
collection PubMed
description BACKGROUND: The risk of coronary obstruction during transcatheter aortic valve-in-valve replacement (VIV-TAVR) in patients deemed at high risk for surgical re-intervention is still a concerning issue. CASE SUMMARY: A 78-year-old woman with a past medical history of hypertension, chronic kidney disease, and rheumatoid arthritis was referred for a symptomatic and severely stenotic surgical Mitroflow n.21 bio-prosthesis and was subsequently recommended for a VIV procedure. Multiple anatomical risk factors for coronary occlusion required a pre-emptive coronary chimney stenting protection. The implantation of an Evolut-R 23 mm valve resulted in a gradient of 21 mmHg thus, a post-dilatation with an 18 mm balloon was performed. Both electrocardiographic and haemodynamic parameters remained excellent, however, a hazardous leaflet dislodgment became evident. Regardless, a prophylactic chimney stenting was performed because of the operator’s perceived high risk of late coronary occlusion. DISCUSSION: The implantation of transcatheter valves inside failed surgically implanted aortic bio-prosthesis is broadly recognized as a safe and less-invasive alternative to repeated high-risk surgery. Although procedural success is achieved in the great majority of patients, this therapy may be jeopardized by rare but serious complications such as impending or established acute coronary occlusion. Several specific anatomical and procedural risk factors have been identified and primary coronary prevention strategies are often mandatory when they arise. Valve-in-valve post-dilation has been overlooked in its role as an additional risk factor of late coronary obstruction. Therefore, chimney stenting, performed after balloon post-dilation to prevent delayed coronary obstruction, even if the acute coronary event does not occur intra-procedurally, is strongly advisable.
format Online
Article
Text
id pubmed-7649518
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-76495182020-11-16 Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report Marchese, Alfredo Tarantini, Giuseppe Tito, Antonio Colombo, Antonio Eur Heart J Case Rep Case Reports BACKGROUND: The risk of coronary obstruction during transcatheter aortic valve-in-valve replacement (VIV-TAVR) in patients deemed at high risk for surgical re-intervention is still a concerning issue. CASE SUMMARY: A 78-year-old woman with a past medical history of hypertension, chronic kidney disease, and rheumatoid arthritis was referred for a symptomatic and severely stenotic surgical Mitroflow n.21 bio-prosthesis and was subsequently recommended for a VIV procedure. Multiple anatomical risk factors for coronary occlusion required a pre-emptive coronary chimney stenting protection. The implantation of an Evolut-R 23 mm valve resulted in a gradient of 21 mmHg thus, a post-dilatation with an 18 mm balloon was performed. Both electrocardiographic and haemodynamic parameters remained excellent, however, a hazardous leaflet dislodgment became evident. Regardless, a prophylactic chimney stenting was performed because of the operator’s perceived high risk of late coronary occlusion. DISCUSSION: The implantation of transcatheter valves inside failed surgically implanted aortic bio-prosthesis is broadly recognized as a safe and less-invasive alternative to repeated high-risk surgery. Although procedural success is achieved in the great majority of patients, this therapy may be jeopardized by rare but serious complications such as impending or established acute coronary occlusion. Several specific anatomical and procedural risk factors have been identified and primary coronary prevention strategies are often mandatory when they arise. Valve-in-valve post-dilation has been overlooked in its role as an additional risk factor of late coronary obstruction. Therefore, chimney stenting, performed after balloon post-dilation to prevent delayed coronary obstruction, even if the acute coronary event does not occur intra-procedurally, is strongly advisable. Oxford University Press 2020-10-13 /pmc/articles/PMC7649518/ /pubmed/33204994 http://dx.doi.org/10.1093/ehjcr/ytaa368 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Marchese, Alfredo
Tarantini, Giuseppe
Tito, Antonio
Colombo, Antonio
Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report
title Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report
title_full Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report
title_fullStr Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report
title_full_unstemmed Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report
title_short Transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report
title_sort transcatheter aortic valve-in-valve post-dilatation as an overlooked risk factor of delayed coronary obstruction: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7649518/
https://www.ncbi.nlm.nih.gov/pubmed/33204994
http://dx.doi.org/10.1093/ehjcr/ytaa368
work_keys_str_mv AT marchesealfredo transcatheteraorticvalveinvalvepostdilatationasanoverlookedriskfactorofdelayedcoronaryobstructionacasereport
AT tarantinigiuseppe transcatheteraorticvalveinvalvepostdilatationasanoverlookedriskfactorofdelayedcoronaryobstructionacasereport
AT titoantonio transcatheteraorticvalveinvalvepostdilatationasanoverlookedriskfactorofdelayedcoronaryobstructionacasereport
AT colomboantonio transcatheteraorticvalveinvalvepostdilatationasanoverlookedriskfactorofdelayedcoronaryobstructionacasereport