An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary

Pressure is one basic parameter involved in microfluidic systems. In this study, we developed an easy capillary-based method for measuring fluid pressure at one or multiple locations in a microchannel. The principal component is a commonly used capillary (inner diameter of 400 μm and 95 mm in length...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Feng, Ai, Mingzhu, Ma, Jianfeng, Li, Zonghe, Xue, Sen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7650790/
https://www.ncbi.nlm.nih.gov/pubmed/33008031
http://dx.doi.org/10.3390/mi11100914
_version_ 1783607554861957120
author Shen, Feng
Ai, Mingzhu
Ma, Jianfeng
Li, Zonghe
Xue, Sen
author_facet Shen, Feng
Ai, Mingzhu
Ma, Jianfeng
Li, Zonghe
Xue, Sen
author_sort Shen, Feng
collection PubMed
description Pressure is one basic parameter involved in microfluidic systems. In this study, we developed an easy capillary-based method for measuring fluid pressure at one or multiple locations in a microchannel. The principal component is a commonly used capillary (inner diameter of 400 μm and 95 mm in length), with one end sealed and calibrated scales on it. By reading the height (h) of an air-liquid interface, the pressure can be measured directly from a table, which is calculated using the ideal gas law. Many factors that affect the relationship between the trapped air volume and applied pressure (p(applied)) have been investigated in detail, including the surface tension, liquid gravity, air solubility in water, temperature variation, and capillary diameters. Based on the evaluation of the experimental and simulation results of the pressure, combined with theoretical analysis, a resolution of about 1 kPa within a full-scale range of 101.6–178 kPa was obtained. A pressure drop (Δp) as low as 0.25 kPa was obtained in an operating range from 0.5 kPa to 12 kPa. Compared with other novel, microstructure-based methods, this method does not require microfabrication and additional equipment. Finally, we use this method to reasonably analyze the nonlinearity of the flow-pressure drop relationship caused by channel deformation. In the future, this one-end-sealed capillary could be used for pressure measurement as easily as a clinical thermometer in various microfluidic applications.
format Online
Article
Text
id pubmed-7650790
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76507902020-11-10 An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary Shen, Feng Ai, Mingzhu Ma, Jianfeng Li, Zonghe Xue, Sen Micromachines (Basel) Article Pressure is one basic parameter involved in microfluidic systems. In this study, we developed an easy capillary-based method for measuring fluid pressure at one or multiple locations in a microchannel. The principal component is a commonly used capillary (inner diameter of 400 μm and 95 mm in length), with one end sealed and calibrated scales on it. By reading the height (h) of an air-liquid interface, the pressure can be measured directly from a table, which is calculated using the ideal gas law. Many factors that affect the relationship between the trapped air volume and applied pressure (p(applied)) have been investigated in detail, including the surface tension, liquid gravity, air solubility in water, temperature variation, and capillary diameters. Based on the evaluation of the experimental and simulation results of the pressure, combined with theoretical analysis, a resolution of about 1 kPa within a full-scale range of 101.6–178 kPa was obtained. A pressure drop (Δp) as low as 0.25 kPa was obtained in an operating range from 0.5 kPa to 12 kPa. Compared with other novel, microstructure-based methods, this method does not require microfabrication and additional equipment. Finally, we use this method to reasonably analyze the nonlinearity of the flow-pressure drop relationship caused by channel deformation. In the future, this one-end-sealed capillary could be used for pressure measurement as easily as a clinical thermometer in various microfluidic applications. MDPI 2020-09-30 /pmc/articles/PMC7650790/ /pubmed/33008031 http://dx.doi.org/10.3390/mi11100914 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shen, Feng
Ai, Mingzhu
Ma, Jianfeng
Li, Zonghe
Xue, Sen
An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary
title An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary
title_full An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary
title_fullStr An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary
title_full_unstemmed An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary
title_short An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary
title_sort easy method for pressure measurement in microchannels using trapped air compression in a one-end-sealed capillary
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7650790/
https://www.ncbi.nlm.nih.gov/pubmed/33008031
http://dx.doi.org/10.3390/mi11100914
work_keys_str_mv AT shenfeng aneasymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT aimingzhu aneasymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT majianfeng aneasymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT lizonghe aneasymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT xuesen aneasymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT shenfeng easymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT aimingzhu easymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT majianfeng easymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT lizonghe easymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary
AT xuesen easymethodforpressuremeasurementinmicrochannelsusingtrappedaircompressioninaoneendsealedcapillary