Cargando…
Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus
Keratoconus is a progressive ectatic corneal disorder, which can result in severe visual impairment. The new ABCD keratoconus classification system allows differentiated description of the disease. Aim of the study was to evaluate the components of this novel staging system (ARC, PRC, thinnest pachy...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7652832/ https://www.ncbi.nlm.nih.gov/pubmed/33168836 http://dx.doi.org/10.1038/s41598-020-76020-6 |
_version_ | 1783607775056625664 |
---|---|
author | Neuhann, Sophie Schuh, Anna Krause, Daniel Liegl, Raffael Schmelter, Valerie Kreutzer, Thomas Mayer, Wolfgang J. Kohnen, Thomas Priglinger, Siegfried Shajari, Mehdi |
author_facet | Neuhann, Sophie Schuh, Anna Krause, Daniel Liegl, Raffael Schmelter, Valerie Kreutzer, Thomas Mayer, Wolfgang J. Kohnen, Thomas Priglinger, Siegfried Shajari, Mehdi |
author_sort | Neuhann, Sophie |
collection | PubMed |
description | Keratoconus is a progressive ectatic corneal disorder, which can result in severe visual impairment. The new ABCD keratoconus classification system allows differentiated description of the disease. Aim of the study was to evaluate the components of this novel staging system (ARC, PRC, thinnest pachymetry) as well as topometric indices, deviation of normality indices, and other parameters in terms of repeatability and reliability. 317 eyes with keratoconus were examined twice with a Scheimpflug device (Pentacam, Oculus). Bland Altman analysis and intraclass correlations were carried out to evaluate the parameters repeatability and reliability. Apart from IHA (ICC = 0.730), all parameters showed excellent reliability (ICC > 0.900). ARC, PRC, thinnest pachymetry, Kmax, CKI, KI, Rmin, and Progression Avg were the best repeatable parameters with relative repeatability values < 2.5%. Other parameters performing well in terms of repeatability were IHD, ISV, IVA, and final D (RR < 13%). Regression analysis revealed consistently high repeatability along all stages of keratoconus for PRC, thinnest pachymetry, and CKI. All parameters of the ABCD staging system showed excellent reliability and repeatability, PRC and thinnest pachymetry even at all stages of keratoconus and can consequently be reliably used in the determination of keratoconus progression. |
format | Online Article Text |
id | pubmed-7652832 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-76528322020-11-12 Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus Neuhann, Sophie Schuh, Anna Krause, Daniel Liegl, Raffael Schmelter, Valerie Kreutzer, Thomas Mayer, Wolfgang J. Kohnen, Thomas Priglinger, Siegfried Shajari, Mehdi Sci Rep Article Keratoconus is a progressive ectatic corneal disorder, which can result in severe visual impairment. The new ABCD keratoconus classification system allows differentiated description of the disease. Aim of the study was to evaluate the components of this novel staging system (ARC, PRC, thinnest pachymetry) as well as topometric indices, deviation of normality indices, and other parameters in terms of repeatability and reliability. 317 eyes with keratoconus were examined twice with a Scheimpflug device (Pentacam, Oculus). Bland Altman analysis and intraclass correlations were carried out to evaluate the parameters repeatability and reliability. Apart from IHA (ICC = 0.730), all parameters showed excellent reliability (ICC > 0.900). ARC, PRC, thinnest pachymetry, Kmax, CKI, KI, Rmin, and Progression Avg were the best repeatable parameters with relative repeatability values < 2.5%. Other parameters performing well in terms of repeatability were IHD, ISV, IVA, and final D (RR < 13%). Regression analysis revealed consistently high repeatability along all stages of keratoconus for PRC, thinnest pachymetry, and CKI. All parameters of the ABCD staging system showed excellent reliability and repeatability, PRC and thinnest pachymetry even at all stages of keratoconus and can consequently be reliably used in the determination of keratoconus progression. Nature Publishing Group UK 2020-11-09 /pmc/articles/PMC7652832/ /pubmed/33168836 http://dx.doi.org/10.1038/s41598-020-76020-6 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Neuhann, Sophie Schuh, Anna Krause, Daniel Liegl, Raffael Schmelter, Valerie Kreutzer, Thomas Mayer, Wolfgang J. Kohnen, Thomas Priglinger, Siegfried Shajari, Mehdi Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus |
title | Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus |
title_full | Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus |
title_fullStr | Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus |
title_full_unstemmed | Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus |
title_short | Comparison of variables measured with a Scheimpflug device for evaluation of progression and detection of keratoconus |
title_sort | comparison of variables measured with a scheimpflug device for evaluation of progression and detection of keratoconus |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7652832/ https://www.ncbi.nlm.nih.gov/pubmed/33168836 http://dx.doi.org/10.1038/s41598-020-76020-6 |
work_keys_str_mv | AT neuhannsophie comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT schuhanna comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT krausedaniel comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT lieglraffael comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT schmeltervalerie comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT kreutzerthomas comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT mayerwolfgangj comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT kohnenthomas comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT priglingersiegfried comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus AT shajarimehdi comparisonofvariablesmeasuredwithascheimpflugdeviceforevaluationofprogressionanddetectionofkeratoconus |