Cargando…
Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor
BACKGROUND: Approximately 2.5 million people in the U.S. suffer from myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). This disease negatively impacts patients’ ability to function, often resulting in difficulty maintaining employment, sustaining financial independence, engaging socially...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7653873/ https://www.ncbi.nlm.nih.gov/pubmed/33168001 http://dx.doi.org/10.1186/s12967-020-02583-7 |
_version_ | 1783607962893287424 |
---|---|
author | Palombo, Turner Campos, Andrea Vernon, Suzanne D. Roundy, Shad |
author_facet | Palombo, Turner Campos, Andrea Vernon, Suzanne D. Roundy, Shad |
author_sort | Palombo, Turner |
collection | PubMed |
description | BACKGROUND: Approximately 2.5 million people in the U.S. suffer from myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). This disease negatively impacts patients’ ability to function, often resulting in difficulty maintaining employment, sustaining financial independence, engaging socially with others, and in particularly severe cases, consistently and adequately performing activities of daily living. The focus of this research was to develop a sensor-based method to measure upright activity defined as time with feet on the floor and referred to as UpTime, as an indicator of ME/CFS disease severity. METHODS: A commercially available inertial measurement unit (IMU), the Shimmer, was selected for this research. A Kalman filter was used to convert IMU data collected by the Shimmer to angle estimates. Angle estimate accuracy was confirmed by comparison to a motion capture system. Leg angle estimates were then converted to personalized daily UpTime scores using a critical angle of 39º from vertical to differentiate between upright (feet on the floor) and not upright. A 6-day, case–control study with 15 subjects (five healthy controls, five moderate-level ME/CFS, and five severe-level ME/CFS) was conducted to determine the utility of UpTime for assessing disease severity. RESULTS: UpTime was found to be a significant measure of ME/CFS disease severity. Severely ill ME/CFS patients spend less than 20% of each day with feet on the floor. Moderately ill ME/CFS patients spend between 20–30% of each day with feet on the floor. Healthy controls have greater than 30% UpTime. IMU-measured UpTime was more precise than self-reported hours of upright activity which were over-estimated by patients. CONCLUSIONS: UpTime is an accurate and objective measure of upright activity, a measure that can be used to assess disease severity in ME/CFS patients. Due to its ability to accurately monitor upright activity, UpTime can also be used as a reliable endpoint for evaluating ME/CFS treatment efficacy. Future studies with larger samples and extended data collection periods are required to fully confirm the use of UpTime as a measure of disease severity in ME/CFS. With the added perspective of large-scale studies, this sensor-based platform could provide a recovery path for individuals struggling with ME/CFS. |
format | Online Article Text |
id | pubmed-7653873 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-76538732020-11-10 Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor Palombo, Turner Campos, Andrea Vernon, Suzanne D. Roundy, Shad J Transl Med Research BACKGROUND: Approximately 2.5 million people in the U.S. suffer from myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). This disease negatively impacts patients’ ability to function, often resulting in difficulty maintaining employment, sustaining financial independence, engaging socially with others, and in particularly severe cases, consistently and adequately performing activities of daily living. The focus of this research was to develop a sensor-based method to measure upright activity defined as time with feet on the floor and referred to as UpTime, as an indicator of ME/CFS disease severity. METHODS: A commercially available inertial measurement unit (IMU), the Shimmer, was selected for this research. A Kalman filter was used to convert IMU data collected by the Shimmer to angle estimates. Angle estimate accuracy was confirmed by comparison to a motion capture system. Leg angle estimates were then converted to personalized daily UpTime scores using a critical angle of 39º from vertical to differentiate between upright (feet on the floor) and not upright. A 6-day, case–control study with 15 subjects (five healthy controls, five moderate-level ME/CFS, and five severe-level ME/CFS) was conducted to determine the utility of UpTime for assessing disease severity. RESULTS: UpTime was found to be a significant measure of ME/CFS disease severity. Severely ill ME/CFS patients spend less than 20% of each day with feet on the floor. Moderately ill ME/CFS patients spend between 20–30% of each day with feet on the floor. Healthy controls have greater than 30% UpTime. IMU-measured UpTime was more precise than self-reported hours of upright activity which were over-estimated by patients. CONCLUSIONS: UpTime is an accurate and objective measure of upright activity, a measure that can be used to assess disease severity in ME/CFS patients. Due to its ability to accurately monitor upright activity, UpTime can also be used as a reliable endpoint for evaluating ME/CFS treatment efficacy. Future studies with larger samples and extended data collection periods are required to fully confirm the use of UpTime as a measure of disease severity in ME/CFS. With the added perspective of large-scale studies, this sensor-based platform could provide a recovery path for individuals struggling with ME/CFS. BioMed Central 2020-11-10 /pmc/articles/PMC7653873/ /pubmed/33168001 http://dx.doi.org/10.1186/s12967-020-02583-7 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Palombo, Turner Campos, Andrea Vernon, Suzanne D. Roundy, Shad Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor |
title | Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor |
title_full | Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor |
title_fullStr | Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor |
title_full_unstemmed | Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor |
title_short | Accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor |
title_sort | accurate and objective determination of myalgic encephalomyelitis/chronic fatigue syndrome disease severity with a wearable sensor |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7653873/ https://www.ncbi.nlm.nih.gov/pubmed/33168001 http://dx.doi.org/10.1186/s12967-020-02583-7 |
work_keys_str_mv | AT palomboturner accurateandobjectivedeterminationofmyalgicencephalomyelitischronicfatiguesyndromediseaseseveritywithawearablesensor AT camposandrea accurateandobjectivedeterminationofmyalgicencephalomyelitischronicfatiguesyndromediseaseseveritywithawearablesensor AT vernonsuzanned accurateandobjectivedeterminationofmyalgicencephalomyelitischronicfatiguesyndromediseaseseveritywithawearablesensor AT roundyshad accurateandobjectivedeterminationofmyalgicencephalomyelitischronicfatiguesyndromediseaseseveritywithawearablesensor |