Cargando…

Assessing forces during spinal manipulation and mobilization: factors influencing the difference between forces at the patient-table and clinician-patient interfaces

BACKGROUND: Spinal manipulative therapy (SMT) and mobilization (MOB) effects are believed to be related to their force characteristics. Most previous studies have either measured the force at the patient-table interface or at the clinician-patient interface. The objectives of this study were to dete...

Descripción completa

Detalles Bibliográficos
Autores principales: Mikhail, Jérémie, Funabashi, Martha, Descarreaux, Martin, Pagé, Isabelle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7654015/
https://www.ncbi.nlm.nih.gov/pubmed/33168008
http://dx.doi.org/10.1186/s12998-020-00346-1
Descripción
Sumario:BACKGROUND: Spinal manipulative therapy (SMT) and mobilization (MOB) effects are believed to be related to their force characteristics. Most previous studies have either measured the force at the patient-table interface or at the clinician-patient interface. The objectives of this study were to determine 1) the difference between the force measured at the patient-table interface and the force applied at the clinician-patient interface during thoracic SMT and MOB, and 2) the influence of the SMT/MOB characteristics, participants’ anthropometry and muscle activity (sEMG) on this difference. METHODS: An apparatus using a servo-linear motor executed 8 SMT/MOB at the T7 vertebrae in 34 healthy adults between May and June 2019. SMT and MOB were characterized by a 20 N preload, total peak forces of 100 N or 200 N, and thrust durations of 100 ms, 250 ms, 1 s or 2 s. During each trial, thoracic sEMG, apparatus displacement as well as forces at the patient-table interface and the clinician-patient interface were recorded. The difference between the force at both interfaces was calculated. The effect of SMT/MOB characteristics on the difference between forces at both interfaces and correlations between this difference and potential influencing factors were evaluated. RESULTS: Force magnitudes at the patient-table interface were, in most trials, greater than the force at the clinician-patient interface (up to 135 N). SMT/MOB characteristics (total peak force, thrust duration and rate of force application) affected the difference between forces at both interfaces (all p-values< 0.05). No factor showed significant correlations with the difference between forces at both interfaces for the 8 SMT/MOB. CONCLUSIONS: The results revealed that the force measured at the patient-table interface is greater than the applied force at the clinician-patient interface during thoracic SMT and MOB. By which mechanism the force is amplified is not yet fully understood.