The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure
PURPOSE: To evaluate the changes in intraocular pressure (IOP), central corneal thickness (CCT), axial length, and ocular surface in patients with end-stage renal failure after single-session hemodialysis treatment and to examine the correlation of these findings with systemic hemodynamic parameters...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7654548/ https://www.ncbi.nlm.nih.gov/pubmed/33192087 http://dx.doi.org/10.2147/IJGM.S281546 |
_version_ | 1783608089992232960 |
---|---|
author | Kalayci, Mustafa Hassan, Ibrahim Ali Keinan, Ibrahim Abdi Cetinkaya, Ersan Suren, Elcin Tahtabasi, Mehmet Sumbul, Hilmi Erdem |
author_facet | Kalayci, Mustafa Hassan, Ibrahim Ali Keinan, Ibrahim Abdi Cetinkaya, Ersan Suren, Elcin Tahtabasi, Mehmet Sumbul, Hilmi Erdem |
author_sort | Kalayci, Mustafa |
collection | PubMed |
description | PURPOSE: To evaluate the changes in intraocular pressure (IOP), central corneal thickness (CCT), axial length, and ocular surface in patients with end-stage renal failure after single-session hemodialysis treatment and to examine the correlation of these findings with systemic hemodynamic parameters. PATIENTS AND METHODS: A total of 112 eyes of 112 patients enrolled in a hemodialysis treatment program for three times a week (approximately four hours per session) for at least three months in our hospital between December 2019 and March 2020 were included in the study. Approximately 30 minutes before and after hemodialysis, the best-corrected visual acuity measurement, slit-lamp examination, IOP measurement, and dilated fundus examination with the Goldmann applanation tonometer were performed in all patients. The axial length measurement was undertaken by ultrasonic biometry, and the CCT measurement by ultrasonic pachymetry. The ocular surface evaluation was performed based on the tear breakup time (BUT), basal secretion time (BST) and keratoepitheliopathy score. Blood pressure, serum osmolarity, and body weight were measured before and after hemodialysis. RESULTS: The mean IOP decreased from 12.2 ± 3.5 to 10.8 ± 2.2 mmHg, and the mean decrease was 1.4 ± 2 mmHg, indicating statistical significance (p<0.001). The mean CCT dropped from 502 ± 41.2 to 494.1 ± 35.4 μm, and the mean decrease was 8.1 ± 7.7 μm, which also indicated a statistically significant change (p<0.001). The mean axial length was reduced from 23.1 ± 0.8 to 22.9 ± 0.8 mm. The reduction in the axial length was significant with an average value of 0.26 ± 0.15 mm (p<0.001). When the ocular surface changes were examined, BUT decreased from 7.4 ± 3.1 to 6.3 ± 2.5 s, BST from 8.6 ± 1.7 to 6.6 ± 1.3 mm, and the keratoepitheliopathy score increased from 0.36 ± 0.61 to 1.59 ± 0.93, and all these changes were statistically significant (p<0.001). There was a significant correlation between the axial length change and the IOP change (r=0.202, p=0.03). A significant correlation was also observed between BST and plasma colloid osmotic pressure (r=−0.268, p=0.004). In addition, there was a strong correlation between serum osmolarity and the keratoepitheliopathy score (r=−0.437, p<0.001). CONCLUSION: Hemodialysis causes significant changes in IOP, CCT, axial length, and ocular surface. These changes should be considered in the ophthalmological examination of patients after the hemodialysis session. |
format | Online Article Text |
id | pubmed-7654548 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-76545482020-11-12 The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure Kalayci, Mustafa Hassan, Ibrahim Ali Keinan, Ibrahim Abdi Cetinkaya, Ersan Suren, Elcin Tahtabasi, Mehmet Sumbul, Hilmi Erdem Int J Gen Med Original Research PURPOSE: To evaluate the changes in intraocular pressure (IOP), central corneal thickness (CCT), axial length, and ocular surface in patients with end-stage renal failure after single-session hemodialysis treatment and to examine the correlation of these findings with systemic hemodynamic parameters. PATIENTS AND METHODS: A total of 112 eyes of 112 patients enrolled in a hemodialysis treatment program for three times a week (approximately four hours per session) for at least three months in our hospital between December 2019 and March 2020 were included in the study. Approximately 30 minutes before and after hemodialysis, the best-corrected visual acuity measurement, slit-lamp examination, IOP measurement, and dilated fundus examination with the Goldmann applanation tonometer were performed in all patients. The axial length measurement was undertaken by ultrasonic biometry, and the CCT measurement by ultrasonic pachymetry. The ocular surface evaluation was performed based on the tear breakup time (BUT), basal secretion time (BST) and keratoepitheliopathy score. Blood pressure, serum osmolarity, and body weight were measured before and after hemodialysis. RESULTS: The mean IOP decreased from 12.2 ± 3.5 to 10.8 ± 2.2 mmHg, and the mean decrease was 1.4 ± 2 mmHg, indicating statistical significance (p<0.001). The mean CCT dropped from 502 ± 41.2 to 494.1 ± 35.4 μm, and the mean decrease was 8.1 ± 7.7 μm, which also indicated a statistically significant change (p<0.001). The mean axial length was reduced from 23.1 ± 0.8 to 22.9 ± 0.8 mm. The reduction in the axial length was significant with an average value of 0.26 ± 0.15 mm (p<0.001). When the ocular surface changes were examined, BUT decreased from 7.4 ± 3.1 to 6.3 ± 2.5 s, BST from 8.6 ± 1.7 to 6.6 ± 1.3 mm, and the keratoepitheliopathy score increased from 0.36 ± 0.61 to 1.59 ± 0.93, and all these changes were statistically significant (p<0.001). There was a significant correlation between the axial length change and the IOP change (r=0.202, p=0.03). A significant correlation was also observed between BST and plasma colloid osmotic pressure (r=−0.268, p=0.004). In addition, there was a strong correlation between serum osmolarity and the keratoepitheliopathy score (r=−0.437, p<0.001). CONCLUSION: Hemodialysis causes significant changes in IOP, CCT, axial length, and ocular surface. These changes should be considered in the ophthalmological examination of patients after the hemodialysis session. Dove 2020-11-06 /pmc/articles/PMC7654548/ /pubmed/33192087 http://dx.doi.org/10.2147/IJGM.S281546 Text en © 2020 Kalayci et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Kalayci, Mustafa Hassan, Ibrahim Ali Keinan, Ibrahim Abdi Cetinkaya, Ersan Suren, Elcin Tahtabasi, Mehmet Sumbul, Hilmi Erdem The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure |
title | The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure |
title_full | The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure |
title_fullStr | The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure |
title_full_unstemmed | The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure |
title_short | The Effect of Hemodialysis on Axial Length, Ocular Surface, and Intraocular Pressure in Patients with End-Stage Renal Failure |
title_sort | effect of hemodialysis on axial length, ocular surface, and intraocular pressure in patients with end-stage renal failure |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7654548/ https://www.ncbi.nlm.nih.gov/pubmed/33192087 http://dx.doi.org/10.2147/IJGM.S281546 |
work_keys_str_mv | AT kalaycimustafa theeffectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT hassanibrahimali theeffectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT keinanibrahimabdi theeffectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT cetinkayaersan theeffectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT surenelcin theeffectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT tahtabasimehmet theeffectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT sumbulhilmierdem theeffectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT kalaycimustafa effectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT hassanibrahimali effectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT keinanibrahimabdi effectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT cetinkayaersan effectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT surenelcin effectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT tahtabasimehmet effectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure AT sumbulhilmierdem effectofhemodialysisonaxiallengthocularsurfaceandintraocularpressureinpatientswithendstagerenalfailure |