Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements

Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made,...

Descripción completa

Detalles Bibliográficos
Autores principales: Moghimirad, Elahe, Bamber, Jeffrey, Harris, Emma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOP Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7655116/
https://www.ncbi.nlm.nih.gov/pubmed/30917360
http://dx.doi.org/10.1088/1361-6560/ab13f2
_version_ 1783608173947518976
author Moghimirad, Elahe
Bamber, Jeffrey
Harris, Emma
author_facet Moghimirad, Elahe
Bamber, Jeffrey
Harris, Emma
author_sort Moghimirad, Elahe
collection PubMed
description Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to use plane wave (PW) or focused imaging (FI), and the values for parameters such as transmit frequency, F-number, mechanical index, and number of compounding angles (for PW imaging). CEUS image contrast may also be dependent on subject characteristics, e.g. flow speed and vessel orientation. We evaluated the effect of such choices on vessel contrast for PW and FI in vitro, using 2D ultrasound imaging. CEUS images were obtained using a Vantage(TM) (Verasonics Inc.) and a pulse-inversion (PI) algorithm on a flow phantom. Contrast (C) and contrast reduction (CR) were calculated, where C was the initial ratio of signal in vessel to signal in background and CR was its reduction after 200 frames (acquired in 20 s). Two transducer orientations were used: parallel and perpendicular to the vessel direction. Similar C and CR was achievable for PW and FI by choosing optimal parameter values. PW imaging suffered from high frequency grating lobe artefacts, which may lead to degraded image quality and misinterpretation of data. Flow rate influenced the contrast based on: (1) false contrast increase due to the bubble motion between the PI positive and negative pulses (for both PW and FI), and (2) contrast reduction due to the incoherency caused by bubble motion between the compounding angles (for PW only). The effects were less pronounced for perpendicular transducer orientation compared to a parallel one. Although both effects are undesirable, it may be more straight forward to account for artefacts in FI as it only suffers from the former effect. In conclusion, if higher frame rate imaging is not required (a benefit of PW), FI appears to be a better choice of imaging mode for CEUS, providing greater image quality over PW for similar rates of contrast reduction.
format Online
Article
Text
id pubmed-7655116
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher IOP Publishing
record_format MEDLINE/PubMed
spelling pubmed-76551162020-11-12 Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements Moghimirad, Elahe Bamber, Jeffrey Harris, Emma Phys Med Biol Paper Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to use plane wave (PW) or focused imaging (FI), and the values for parameters such as transmit frequency, F-number, mechanical index, and number of compounding angles (for PW imaging). CEUS image contrast may also be dependent on subject characteristics, e.g. flow speed and vessel orientation. We evaluated the effect of such choices on vessel contrast for PW and FI in vitro, using 2D ultrasound imaging. CEUS images were obtained using a Vantage(TM) (Verasonics Inc.) and a pulse-inversion (PI) algorithm on a flow phantom. Contrast (C) and contrast reduction (CR) were calculated, where C was the initial ratio of signal in vessel to signal in background and CR was its reduction after 200 frames (acquired in 20 s). Two transducer orientations were used: parallel and perpendicular to the vessel direction. Similar C and CR was achievable for PW and FI by choosing optimal parameter values. PW imaging suffered from high frequency grating lobe artefacts, which may lead to degraded image quality and misinterpretation of data. Flow rate influenced the contrast based on: (1) false contrast increase due to the bubble motion between the PI positive and negative pulses (for both PW and FI), and (2) contrast reduction due to the incoherency caused by bubble motion between the compounding angles (for PW only). The effects were less pronounced for perpendicular transducer orientation compared to a parallel one. Although both effects are undesirable, it may be more straight forward to account for artefacts in FI as it only suffers from the former effect. In conclusion, if higher frame rate imaging is not required (a benefit of PW), FI appears to be a better choice of imaging mode for CEUS, providing greater image quality over PW for similar rates of contrast reduction. IOP Publishing 2019-05 2019-04-23 /pmc/articles/PMC7655116/ /pubmed/30917360 http://dx.doi.org/10.1088/1361-6560/ab13f2 Text en © 2019 Institute of Physics and Engineering in Medicine http://creativecommons.org/licenses/by/3.0/ Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence (http://creativecommons.org/licenses/by/3.0) . Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
spellingShingle Paper
Moghimirad, Elahe
Bamber, Jeffrey
Harris, Emma
Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements
title Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements
title_full Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements
title_fullStr Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements
title_full_unstemmed Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements
title_short Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements
title_sort plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements
topic Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7655116/
https://www.ncbi.nlm.nih.gov/pubmed/30917360
http://dx.doi.org/10.1088/1361-6560/ab13f2
work_keys_str_mv AT moghimiradelahe planewaveversusfocusedtransmissionsforcontrastenhancedultrasoundimagingtheroleofparametersettingsandtheeffectsofflowrateoncontrastmeasurements
AT bamberjeffrey planewaveversusfocusedtransmissionsforcontrastenhancedultrasoundimagingtheroleofparametersettingsandtheeffectsofflowrateoncontrastmeasurements
AT harrisemma planewaveversusfocusedtransmissionsforcontrastenhancedultrasoundimagingtheroleofparametersettingsandtheeffectsofflowrateoncontrastmeasurements