Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study
To investigate potential correlations between objective CBCT image parameters and accuracy in endodontic working length determination ex vivo. Contrast-to-noise ratio (CNR) and spatial resolution (SR) as fundamental objective image parameters were examined using specific phantoms in seven different...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7655868/ https://www.ncbi.nlm.nih.gov/pubmed/33173072 http://dx.doi.org/10.1038/s41598-020-76424-4 |
_version_ | 1783608259941236736 |
---|---|
author | Wolf, T. G. Fischer, F. Schulze, R. K. W. |
author_facet | Wolf, T. G. Fischer, F. Schulze, R. K. W. |
author_sort | Wolf, T. G. |
collection | PubMed |
description | To investigate potential correlations between objective CBCT image parameters and accuracy in endodontic working length determination ex vivo. Contrast-to-noise ratio (CNR) and spatial resolution (SR) as fundamental objective image parameters were examined using specific phantoms in seven different CBCT machines. Seven experienced observers were instructed and calibrated. The order of the CBCTs was randomized for each observer and observation. To assess intra-operator reproducibility, the procedure was repeated within six weeks with a randomized order of CBCT images. Multivariate analysis (MANOVA) did not reveal any influence of the combined image quality factors CNR and SR on measurement accuracy. Inter-operator reproducibility as assessed between the two observations was poor, with a mean intra-class correlation (ICC) of 0.48 (95%-CI 0.38, 0.59) for observation No. 1. and 0.40 (95%-CI 0.30, 0.51) for observation No. 2. Intra-operator reproducibility pooled over all observers between both observations was only moderate, with a mean ICC of 0.58 (95%-CI 0.52 to 0.64). Within the limitations of the study, objective image quality measures and exposure parameters seem not to have a significant influence on accuracy in determining endodontic root canal lengths in CBCT scans. The main factor of variance is the observer. |
format | Online Article Text |
id | pubmed-7655868 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-76558682020-11-12 Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study Wolf, T. G. Fischer, F. Schulze, R. K. W. Sci Rep Article To investigate potential correlations between objective CBCT image parameters and accuracy in endodontic working length determination ex vivo. Contrast-to-noise ratio (CNR) and spatial resolution (SR) as fundamental objective image parameters were examined using specific phantoms in seven different CBCT machines. Seven experienced observers were instructed and calibrated. The order of the CBCTs was randomized for each observer and observation. To assess intra-operator reproducibility, the procedure was repeated within six weeks with a randomized order of CBCT images. Multivariate analysis (MANOVA) did not reveal any influence of the combined image quality factors CNR and SR on measurement accuracy. Inter-operator reproducibility as assessed between the two observations was poor, with a mean intra-class correlation (ICC) of 0.48 (95%-CI 0.38, 0.59) for observation No. 1. and 0.40 (95%-CI 0.30, 0.51) for observation No. 2. Intra-operator reproducibility pooled over all observers between both observations was only moderate, with a mean ICC of 0.58 (95%-CI 0.52 to 0.64). Within the limitations of the study, objective image quality measures and exposure parameters seem not to have a significant influence on accuracy in determining endodontic root canal lengths in CBCT scans. The main factor of variance is the observer. Nature Publishing Group UK 2020-11-10 /pmc/articles/PMC7655868/ /pubmed/33173072 http://dx.doi.org/10.1038/s41598-020-76424-4 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Wolf, T. G. Fischer, F. Schulze, R. K. W. Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study |
title | Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study |
title_full | Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study |
title_fullStr | Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study |
title_full_unstemmed | Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study |
title_short | Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study |
title_sort | correlation of objective image quality and working length measurements in different cbct machines: an ex vivo study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7655868/ https://www.ncbi.nlm.nih.gov/pubmed/33173072 http://dx.doi.org/10.1038/s41598-020-76424-4 |
work_keys_str_mv | AT wolftg correlationofobjectiveimagequalityandworkinglengthmeasurementsindifferentcbctmachinesanexvivostudy AT fischerf correlationofobjectiveimagequalityandworkinglengthmeasurementsindifferentcbctmachinesanexvivostudy AT schulzerkw correlationofobjectiveimagequalityandworkinglengthmeasurementsindifferentcbctmachinesanexvivostudy |