Accuracy of UK Rapid Test Consortium (UK-RTC) “AbC-19 Rapid Test” for detection of previous SARS-CoV-2 infection in key workers: test accuracy study

OBJECTIVE: To assess the accuracy of the AbC-19 Rapid Test lateral flow immunoassay for the detection of previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. DESIGN: Test accuracy study. SETTING: Laboratory based evaluation. PARTICIPANTS: 2847 key workers (healthcare staf...

Descripción completa

Detalles Bibliográficos
Autores principales: Mulchandani, Ranya, Jones, Hayley E, Taylor-Phillips, Sian, Shute, Justin, Perry, Keith, Jamarani, Shabnam, Brooks, Tim, Charlett, Andre, Hickman, Matthew, Oliver, Isabel, Kaptoge, Stephen, Danesh, John, Di Angelantonio, Emanuele, Ades, Anthony E, Wyllie, David H, Armitage, Jane, Borrow, Ray, Boyes, John, Cullen, Donna, Hormis, Anil, Linley, Ezra, Mehenny, Susan, Miflin, Gail, Moore, Carmel, Moore, Philippa, Reckless, Ian, Roberts, David J, Sambrook, Jennifer, Todd, Neil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group Ltd. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7656121/
https://www.ncbi.nlm.nih.gov/pubmed/33177070
http://dx.doi.org/10.1136/bmj.m4262
Descripción
Sumario:OBJECTIVE: To assess the accuracy of the AbC-19 Rapid Test lateral flow immunoassay for the detection of previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. DESIGN: Test accuracy study. SETTING: Laboratory based evaluation. PARTICIPANTS: 2847 key workers (healthcare staff, fire and rescue officers, and police officers) in England in June 2020 (268 with a previous polymerase chain reaction (PCR) positive result (median 63 days previously), 2579 with unknown previous infection status); and 1995 pre-pandemic blood donors. MAIN OUTCOME MEASURES: AbC-19 sensitivity and specificity, estimated using known negative (pre-pandemic) and known positive (PCR confirmed) samples as reference standards and secondly using the Roche Elecsys anti-nucleoprotein assay, a highly sensitive laboratory immunoassay, as a reference standard in samples from key workers. RESULTS: Test result bands were often weak, with positive/negative discordance by three trained laboratory staff for 3.9% of devices. Using consensus readings, for known positive and negative samples sensitivity was 92.5% (95% confidence interval 88.8% to 95.1%) and specificity was 97.9% (97.2% to 98.4%). Using an immunoassay reference standard, sensitivity was 94.2% (90.7% to 96.5%) among PCR confirmed cases but 84.7% (80.6% to 88.1%) among other people with antibodies. This is consistent with AbC-19 being more sensitive when antibody concentrations are higher, as people with PCR confirmation tended to have more severe disease whereas only 62% (218/354) of seropositive participants had had symptoms. If 1 million key workers were tested with AbC-19 and 10% had actually been previously infected, 84 700 true positive and 18 900 false positive results would be projected. The probability that a positive result was correct would be 81.7% (76.8% to 85.8%). CONCLUSIONS: AbC-19 sensitivity was lower among unselected populations than among PCR confirmed cases of SARS-CoV-2, highlighting the scope for overestimation of assay performance in studies involving only PCR confirmed cases, owing to “spectrum bias.” Assuming that 10% of the tested population have had SARS-CoV-2 infection, around one in five key workers testing positive with AbC-19 would be false positives. STUDY REGISTRATION: ISRCTN 56609224.