Cargando…

Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire

BACKGROUND: The clinical outcome of open reduction and internal fixation (ORIF) for delayed lateral condylar fracture of the humerus (LCFH) varies in different studies, but ORIF for LCFH with an early-delayed presentation usually resulted in significant improvement of elbow function. Early delayed p...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jin, Rai, Saroj, Gao, Yun, Ze, Renhao, Tang, Xin, Liu, Ruikang, Hong, Pan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7656681/
https://www.ncbi.nlm.nih.gov/pubmed/33176748
http://dx.doi.org/10.1186/s12891-020-03774-5
_version_ 1783608400574152704
author Li, Jin
Rai, Saroj
Gao, Yun
Ze, Renhao
Tang, Xin
Liu, Ruikang
Hong, Pan
author_facet Li, Jin
Rai, Saroj
Gao, Yun
Ze, Renhao
Tang, Xin
Liu, Ruikang
Hong, Pan
author_sort Li, Jin
collection PubMed
description BACKGROUND: The clinical outcome of open reduction and internal fixation (ORIF) for delayed lateral condylar fracture of the humerus (LCFH) varies in different studies, but ORIF for LCFH with an early-delayed presentation usually resulted in significant improvement of elbow function. Early delayed presentation is defined as a period of 3 to 12 weeks from the injury. This study aims to compare the clinical outcomes of biodegradable pin (BP) vs. Kirschner wire (KW) in the treatment of LCFH with an early delayed presentation. METHODS: LCFH with an early-delayed presentation treated with KW or BP were retrospectively reviewed in our hospital. The patients were divided into two groups KW (n = 17) and BP group (n = 26). Baseline information, including sex, age, operative side, duration from injury to surgery, and implant choice, was reviewed. Radiographs and medical records were collected from the Hospital Database. RESULTS: In all, 17 patients (male/female, 9/8) in KW and 26 patients (male/female,13/13) in the BP group were included. The age showed no statistically significant difference between the KW (52.3 ± 10.2, month) and the BP (56.1 ± 10.7, month), (P = 0.258). At the last follow-up, there existed no statistically significant difference between the two groups concerning Baumann’s angle (P = 0.272) and carrying angle (P = 0.911). The MEPS at the last follow-up was better in the KW group (91.1 ± 2.7) than the BP group (89.2 ± 3.0), (P = 0.048). There was no case of nonunion or malunion in both groups. The incidence of fishtail deformity was (8/17, 47.1%) in KW and (13/26, 50%) in the BP group. The incidence of lateral prominence was (5/17, 29.4%) in the KW and (7/26, 26.9%) in the BP group. Furthermore, the incidence of implant prominence was higher in KW (12/17, 70.6%) than BP (0) (P <  0.001). CONCLUSION: Open reduction and internal fixation for LCFH with an early-delayed presentation produced satisfactory outcomes. Biodegradable pin is a good alternative to Kirschner wire, with comparable clinical outcomes.
format Online
Article
Text
id pubmed-7656681
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-76566812020-11-12 Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire Li, Jin Rai, Saroj Gao, Yun Ze, Renhao Tang, Xin Liu, Ruikang Hong, Pan BMC Musculoskelet Disord Research Article BACKGROUND: The clinical outcome of open reduction and internal fixation (ORIF) for delayed lateral condylar fracture of the humerus (LCFH) varies in different studies, but ORIF for LCFH with an early-delayed presentation usually resulted in significant improvement of elbow function. Early delayed presentation is defined as a period of 3 to 12 weeks from the injury. This study aims to compare the clinical outcomes of biodegradable pin (BP) vs. Kirschner wire (KW) in the treatment of LCFH with an early delayed presentation. METHODS: LCFH with an early-delayed presentation treated with KW or BP were retrospectively reviewed in our hospital. The patients were divided into two groups KW (n = 17) and BP group (n = 26). Baseline information, including sex, age, operative side, duration from injury to surgery, and implant choice, was reviewed. Radiographs and medical records were collected from the Hospital Database. RESULTS: In all, 17 patients (male/female, 9/8) in KW and 26 patients (male/female,13/13) in the BP group were included. The age showed no statistically significant difference between the KW (52.3 ± 10.2, month) and the BP (56.1 ± 10.7, month), (P = 0.258). At the last follow-up, there existed no statistically significant difference between the two groups concerning Baumann’s angle (P = 0.272) and carrying angle (P = 0.911). The MEPS at the last follow-up was better in the KW group (91.1 ± 2.7) than the BP group (89.2 ± 3.0), (P = 0.048). There was no case of nonunion or malunion in both groups. The incidence of fishtail deformity was (8/17, 47.1%) in KW and (13/26, 50%) in the BP group. The incidence of lateral prominence was (5/17, 29.4%) in the KW and (7/26, 26.9%) in the BP group. Furthermore, the incidence of implant prominence was higher in KW (12/17, 70.6%) than BP (0) (P <  0.001). CONCLUSION: Open reduction and internal fixation for LCFH with an early-delayed presentation produced satisfactory outcomes. Biodegradable pin is a good alternative to Kirschner wire, with comparable clinical outcomes. BioMed Central 2020-11-11 /pmc/articles/PMC7656681/ /pubmed/33176748 http://dx.doi.org/10.1186/s12891-020-03774-5 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Li, Jin
Rai, Saroj
Gao, Yun
Ze, Renhao
Tang, Xin
Liu, Ruikang
Hong, Pan
Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire
title Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire
title_full Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire
title_fullStr Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire
title_full_unstemmed Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire
title_short Biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. Kirschner wire
title_sort biodegradable pins for lateral condylar fracture of the humerus with an early delayed presentation in children: a retrospective study of biodegradable pin vs. kirschner wire
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7656681/
https://www.ncbi.nlm.nih.gov/pubmed/33176748
http://dx.doi.org/10.1186/s12891-020-03774-5
work_keys_str_mv AT lijin biodegradablepinsforlateralcondylarfractureofthehumeruswithanearlydelayedpresentationinchildrenaretrospectivestudyofbiodegradablepinvskirschnerwire
AT raisaroj biodegradablepinsforlateralcondylarfractureofthehumeruswithanearlydelayedpresentationinchildrenaretrospectivestudyofbiodegradablepinvskirschnerwire
AT gaoyun biodegradablepinsforlateralcondylarfractureofthehumeruswithanearlydelayedpresentationinchildrenaretrospectivestudyofbiodegradablepinvskirschnerwire
AT zerenhao biodegradablepinsforlateralcondylarfractureofthehumeruswithanearlydelayedpresentationinchildrenaretrospectivestudyofbiodegradablepinvskirschnerwire
AT tangxin biodegradablepinsforlateralcondylarfractureofthehumeruswithanearlydelayedpresentationinchildrenaretrospectivestudyofbiodegradablepinvskirschnerwire
AT liuruikang biodegradablepinsforlateralcondylarfractureofthehumeruswithanearlydelayedpresentationinchildrenaretrospectivestudyofbiodegradablepinvskirschnerwire
AT hongpan biodegradablepinsforlateralcondylarfractureofthehumeruswithanearlydelayedpresentationinchildrenaretrospectivestudyofbiodegradablepinvskirschnerwire