Emergent surgical removal of a migrated atrial septal defect occluder: case report
BACKGROUND: Atrial septal defect (ASD) closure has been widely accepted and is now routinely performed using a percutaneous approach under especially echocardiographic guidance Transesophageal echocardiography (TEE). One major complication is dislocation of occluder device during or after the device...
Autores principales: | Wen, Bi, He, Juan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7656709/ https://www.ncbi.nlm.nih.gov/pubmed/33176835 http://dx.doi.org/10.1186/s13019-020-01350-5 |